Showing of 1 until 15 from 94 result(s)
Search for: Biomarkers; Diabetic retinopathy; Differential diagnosis; Oxides; Type 2 diabetes mellitus; Trimethylamine-N-oxide; Trimethyloxamine
Abstract
Objetivo: Avaliar a prevalência de retinopatia diabética (RD) em uma associação de diabéticos, bem como o nível de informação dos pacientes a respeito desta doença. Métodos: O estudo avaliou, aleatoriamente, 46 pacientes de uma associação de diabéticos que responderam a perguntas sobre conhecimento da RD e avaliação oftalmoscópica prévia e foram submetidos à exame de fundo de olho por oftalmoscopia binocular indireta. Resultados: Entre os diabéticos tipo 1, o estudo encontrou 44,44% dos pacientes com RD e um caso de RD proliferativa; entre os diabéticos tipo 2, 24,3% possuíam RD; 65,22% dos indivíduos avaliados nunca haviam feito exame de oftalmoscopia, embora 80,43% já haviam tido alguma informação sobre RD. Conclusões: Concluímos que há baixa cobertura em termos de prevenção e detecção da RD nesta associação de diabéticos, o que contrasta com o nível de informação dos pacientes sobre a doença e com o fato de ser uma entidade voltada exclusivamente para o tratamento do diabete.
Keywords: Diabete melito; Retinopatia
Abstract
Objetivo: Investigar a associação de desfechos anatômicos com doenças sistêmicas e medicamentos em casos submetidos à ceratoplastia endotelial da membrana de Descemet e fatores relativos aos doadores.
Métodos: Foram incluídos neste estudo retrospectivo enxertos obtidos de doadores não diabéticos e 60 casos operados por um único cirurgião. Foram registrados os dados dos casos, incluindo a presença de diabetes mellitus e hipertensão, medicamentos antidiabéticos e anti-hipertensivos, tamponamentos intracamerais e desfechos anatômicos. Os dados dos doadores foram obtidos dos prontuários do banco de olhos.
Resultados: Dezoito casos tinham diabetes mellitus tipo 2 (30%) e 34 tinham hipertensão (56,6%). Entre os casos de diabetes mellitus, 13 estavam em uso de uma medicação antidiabética de agente único, 4 estavam em terapia antidiabética oral dupla e 1 estava em insulinoterapia. Entre os hipertensos, 11 estavam em monoterapia e 23 em terapia anti-hipertensiva dupla. No pós-operatório, 35 pacientes (58,3%) submeteram-se a uma fixação endotelial, enquanto 8 casos (13,3%) receberam reinjeção, 7 casos (11,7%) necessitaram de ceratoplastia endotelial da membrana de Descemet e 10 casos (16,7%) foram submetidos a uma ceratoplastia penetrante. A média de idade dos doadores foi de 51,2 ± 14,1 anos. A causa mais comum de morte do doador foi parada cardiorrespiratória (36/60 casos; 60,0%). A análise de regressão revelou que a presença de diabetes mellitus causa distúrbios significativos na fixação do enxerto (p=0,034), enquanto a presença de hipertensão, o uso de medicamentos antidiabéticos e anti-hipertensivos, o tipo de tamponamento usado, a idade, o sexo, a causa da morte e a contagem de células endoteliais especulares dos doadores não demonstraram associações estatisticamente significativas com a fixação do enxerto (p>0,05).
Conclusão: Os resultados anatômicos da cirurgia de ceratoplastia endotelial da membrana de Descemet são afetados por fatores do receptor e do doador. A presença de diabetes mellitus no receptor teve um significativo impacto negativo na fixação do enxerto.
Keywords: Membrana de Descemet; Ceratoplastia endotelial; Diabetes mellitus; Contagem de células endoteliais; Hipertensão
Abstract
Objetivo: Avaliar a relação da espessura subfoveal da coroide e dos níveis plasmáticos de dimetil-arginina assimétrica com a gravidade da retinopatia diabética em pacientes com diabetes mellitus tipo 2.
Métodos: Foram incluídos 68 casos, compreendendo 15 pacientes sem retinopatia diabética, 17 pacientes com retinopatia diabética não proliferativa, 16 pacientes com retinopatia diabética proliferativa, e 20 casos saudáveis (grupo de controle). A espessura subfoveal da coroide foi medida manualmente, usando o programa de varredura com tomografia computadorizada óptica com imagem profunda aprimorada, e os níveis plasmáticos de dimetil-arginina assimétrica foram medidos usando um kit microELISA comercial.
Resultados: Os valores da espessura subfoveal da coroide e os níveis plasmáticos de dimetil-arginina assimétrica foram significativamente diferentes nos quatro grupos (p<0,001 para ambos os parâmetros). Os valores da espessura subfoveal da coroide foram significativamente menores no grupo com retinopatia diabética proliferativa do que nos outros três grupos (sem retinopatia diabética, retinopatia diabética não proliferativa e grupo de controle, com p<0,001, p=0,045 e p<0,001, respectivamente). Já os níveis plasmáticos de dimetil-arginina assimétrica foram significativamente maiores no grupo com retinopatia diabética proliferativa do que nos outros três grupos (p<0,001, p=0,04 e p<0,001, respectivamente). Além disso, também foi encontrada uma correlação negativa significativa entre os níveis plasmáticos de dimetil-arginina assimétrica e a espessura subfoveal da coroide (p<0,001, r=-0,479).
Conclusão: A dimetil-arginina assimétrica é um importante marcador de disfunção endotelial e um inibidor endógeno da óxido nítrico sintase. Foi encontrada uma relação da gravidade da retinopatia diabética e de níveis elevados de dimetil-arginina assimétrica no plasma com a redução da espessura subfoveal da coroide em pacientes diabéticos tipo 2 com retinopatia diabética.
Keywords: Diabetes Mellitus, Tipo 2; Retinopatia diabética; Coroide; Fóvea central; Óxido nítrico; Arginina; Tomografia de coerência óptica
Abstract
Objetivo: Comparar a estrutura da córnea e as alterações morfológicas endoteliais após cirurgia de catarata por facoemulsificação sem intercorrências entre pacientes com diabetes mellitus tipo 2 e não diabéticos; e determinar quais fatores pré e intra-operatórios relacionados com a maior redução da densidade celular endotelial.
Métodos: Quarenta e cinco diabéticos (45 olhos) e 43 (43 olhos) controlos com catarata relacionada à idade foram incluídos neste estudo observacional prospectivo. Os parâmetros da córnea (espessura e volume) e do segmento anterior foram medidos pela tomografia Scheimpflug; a densidade e morfologia celular endotelial (coeficiente de variação do tamanho das células, células hexagonais) foram registrados usando microscopia especular não contato. Os pacientes foram avaliados no pré-operatório, 1 e 6 meses após a cirurgia. Foi realizada uma análise de regressão linear uni e multivariada para avaliar a relação entre os parâmetros demográficos, clínicos, oculares e intra-operatórios com a redução da densidade celular endotelial aos 6 meses.
Resultados: Nos dois grupos houve uma perda significativa de células endoteliais ao 1º mês pós-operatório (p<0,001), que permaneceu estável até ao 6º mês; sem diferenças estatisticas entre os grupos diabetes mellitus e não diabetes mellitus em qualquer avaliação. A espessura média da córnea no pós-operatório central aos 1 e 6 meses não mudou significativamente em relação ao valor médio pré-operatório nos dois grupos (p>0.05). A análise de regressão multivariada linear mostrou que a idade avançada (p=0.042) e os graus mais elevados de catarata (p=0.001) foram significativamente associados à maior redução densidade celular endotelial aos 6 meses de seguimento.
Conclusão: Este estudo mostrou que a idade avançada e as cataratas mais densas podem predispor a uma maior redução densidade celular endotelial após a cirurgia de catarata. Outros fatores, como diabetes mellitus e parâmetros pré-operatórios do segmento anterior, não influenciaram significativamente as alterações pós-operatórias da densidade celular endotelial.
Keywords: Catarata; Facoemulsificação; Diabetes mellitus tipo 2; Retinopatia diabética; Epitélio posterior; Paquimetria corneana; Perda de células endoteliais da córnea
Abstract
Objetivos: Procuramos avaliar o uso da pupilometria estática e dinâmica quantitativa automatizada na triagem de pacientes com diabetes mellitus tipo 2 e em diferentes estágios de retinopatia diabética.
Métodos: Cento e cinquenta e cinco pacientes com diabetes mellitus tipo 2 (grupo com diabetes mellitus) foram incluídos neste estudo e outros 145 controles saudáveis pareados por idade e sexo para server como grupo controle. O grupo com diabetes mellitus foi dividido em três subgrupos: diabetes mellitus sem retinopatia diabética (retinopatia não diabética), retinopatia diabética não proliferativa e retinopatia diabética proliferativa. A pupilometria estática e dinâmica foi realizada utilizando uma camera rotative Scheimpflug com um sistema baseado em topografia.
Resultados: Em termos de diâmetro da pupila, tanto na pupilometria estática quanto na dinâmica (p<0,05), foram observadas diferenças estatisticamente significantes entre os grupos diabetes mellitus e controle e também entre os subgrupos retinopatia não diabética, retinopatia diabética não proliferativa e retinopatia diabética proliferativa. Mas foi observado que os grupos de retinopatia não diabética e retinopatia diabética não proliferativa mostraram semelhanças nos achados derivados da pupilometria estática em condições mesópicas e fotópicas. Os dois grupos também pareciam semelhantes em todos os pontos durante a pupilometria dinâmica (p>0,05). No entanto, pode-se concluir que o grupo de retinopatia diabética proliferative foi sugnificativamente diferente do restante dos subgrupos, retinopatia não diabética e retinopatia diabética não proliferativa, em termos de todas as medidas de pupilometris estática (p<0,05). A velocidade média de dilatação também foi significativamente diferente entre os grupos diabetes mellitus e controle, e entre os subgrupos diabetes mellitus (p<0,001). Enquanto correlações significativas fracas a moderadas foram encontradas entre todos os diâmetros da pupila na pupilometria estática e dinâmica com a duração do diabetes mellitus (p<0,05 para todos), os valores de HbA1c não mostraram correlações estatisticamente significantes com nenhum dos diâmetros da pupila estática e dinâmica investigados (p>0,05 para todos).
Conclusão: Este estudo revelou que as medidas derivadas da pupilometria automatizada estão alteradas em pacientes com diabetes mellitus tipo 2. A presença de retinopatia diabética não proliferativa não afeta negativamente os achados pupilométricos, mas com a retinopatia diabética proliferative, alterações significativas foram observadas. Estes resultados sugerem que o uso da pupilometria quantitativa automatizada pode ser útil na verificação gravidade da retinopatia diabética.
Keywords: Retinopatia diabética; Diabetes Mellitus; Técnicas de diagnóstico oftalmológico; Pupila; Reflexo pupilar
Abstract
OBJETIVO: Descrever alterações microvasculares na mácula em diabéticos do tipo 2 sem retinopatia diabética e pacientes saudáveis, e correlacionar achados com perfil clínico nos diabéticos.
MÉTODOS: Foram incluídos 60 olhos de 30 diabéticos e 30 pacientes saudáveis. Diabéticos realizaram fundoscopia, retinografia® (CR2; Canon Inc., New York, New York, USA) e angiografia fluoresceínica® (TRC-50DXC; Topcon Inc., Tokyo, Japan) para descartar a presença de retinopatia. Os 60 pacientes realizaram a angiografia por tomografia de coerência óptica® (RTVue XR, Avanti, Optovue, Fremont, CA, USA) (área macular: 6 x 6 mm2) e foram analisados densidade vascular total, foveal e parafoveal no plexo capilar superficial e plexo capilar profundo, espessura foveal, espessura parafoveal, área da zona avascular da fóvea no plexo capilar superficial e área de fluxo da coriocapilar. Resultados da angiografia por tomografia de coerência óptica foram comparados entre os 2 grupos e correlacionados com acuidade visual, tempo de diabetes, controle glicêmico, perfil lipídico e função renal nos diabéticos.
RESULTADOS: Observou-se aumento mínimo da área de fluxo da coriocapilar nos diabéticos, média das áreas foi de 22,3 ± 4,6 mm² no grupo controle e 22,6 ± 3,9 mm² em diabéticos (p=0,017). Não foi observada diferença estatisticamente significante entre outras variáveis da angiografia por tomografia de coerência óptica analisadas nos dois grupos. Hemoglobina glicosilada e glicemia de jejum apresentaram correlação negativa estatisticamente significante com densidade vascular foveal de ambos os plexos e a glicemia de jejum se correlacionou positivamente com área de fluxo da coriocapilar (p=0,034). Outros dados clínicos avaliados não apresentaram correlação com achados da angiografia por tomografia de coerência óptica.
CONCLUSÃO: Resultados sugerem que a angiografia por tomografia de coerência óptica pode não ser a melhor ferramenta na detecção de alterações pré-clínicas em diabéticos, não substituindo o exame clínico, e corroboram a ideia de que o controle glicêmico deve ser o principal parâmetro clínico a ser considerado na triagem da retinopatia. Estudos com amostras maiores são necessários para confirmar os achados.
Keywords: Angiografia; Diabetes mellitus; Retinopatia diabética; Diagnóatico por imagem; Tomografia de coerência óptica
Abstract
PURPOSE: This study evaluated macular thickness using spectral-domain optical coherence tomography in healthy participants from a population-based eye survey.
METHODS: The Brazilian Amazon Region Eye Survey was a population-based study assessing the prevalence and causes of visual impairment, blindness, and ocular diseases in adults aged ≥45 years from urban and rural areas of Parintins. A subgroup was selected based on inclusion criteria for both eyes: best-corrected visual acuity ≥20/32, normal eye examination results, and no prior ocular surgery. Scans were performed using the iVue optical coherence tomography device. Measurements were taken from the nine subfields defined by the Early Treatment Diabetic Retinopathy Study, examining the full retina as well as the inner and outer retinal layers. Associations of retinal thickness with age and sex were also analyzed. Statistical significance was set at p≤0.05.
RESULTS: In total, 70 healthy participants (25 males), aged 45–65 years (mean=52 ± 5), were included. Mean central foveal thickness was 248.71 ± 18.73 μm. A significant age-related reduction in macular thickness was observed, particularly in the inner superior parafovea (p=0.036), nasal perifovea (p=0.001), superior perifovea (p=0.028), outer layer of inferior parafovea (p=0.049), and the inferior perifovea of the full retina (p=0.029). Males showed significantly greater thickness in the outer layer, especially in the outer parafovea (p=0.004) and perifovea (p<0.0001).
CONCLUSIONS: This study established normative macular thickness values for healthy older adults in the Brazilian Amazon region using spectral-domain optical coherence tomography. Age and sex were found to significantly influence macular thickness and should be considered when interpreting measurements. These data will support future studies of retinal diseases in this population.
Keywords: Retinal diseases/diagnosis; Macula lutea/pathology; Macular degeneration/diagnosis; Diabetic retinopathy/diagnosis; Vision, low; Vision tests; Tomography, optical coherence/methods; Young adult; Cross-sectional studies; Brazil/epidemiology
Abstract
PURPOSE: To evaluate whether specific meibomian gland morphological features can serve as diagnostic indicators of dry eye disease in patients with type 2 diabetes mellitus.
METHODS: This cross-sectional study included patients with type 2 diabetes mellitus and age-matched healthy controls. All participants underwent a comprehensive ocular surface evaluation, including the ocular surface disease index, tear break-up time, Schirmer’s I test, corneal staining, eyelid margin scoring, meibum expressibility assessment, meibography scoring, and evaluation of meibomian gland loss area. Meibomian gland morphology was assessed bilaterally. Dry eye severity was determined based on ocular surface disease index scores, tear break-up time, Schirmer’s test results, and corneal staining scores. Correlations between meibomian gland features and ocular surface parameters, age, diabetes duration, and hemoglobin A1c levels were analyzed. Receiver operating characteristic analysis was performed to determine the diagnostic value of specific meibomian gland features for dry eye disease.
RESULTS: Dry eye disease was diagnosed in 56.6% of patients with diabetes and 22.6% of controls. Compared with controls, patients with diabetes had significantly higher ocular surface disease index scores, greater corneal staining, worse meibum expressibility, increased meibomian gland loss, and lower tear break-up time and Schirmer values (all p<0.05). Meibomian gland dropout, shortening, tortuosity, distortion, overlapping, ghost glands, and lack of extension to the lid margin were significantly more prevalent in patients with diabetes (p<0.05) and showed significant correlations with age, HbA1c levels, and diabetes mellitus duration. Receiver operating characteristic analysis identified meibomian gland dropout, ghost glands, shortening, and lack of extension to the lid margin as the most predictive morphological features for dry eye disease in patients with diabetes.
CONCLUSION: Type 2 diabetes mellitus is associated with distinct meibomian gland morphological alterations that correlate with both dry eye disease severity and systemic diabetic parameters, suggesting potential diagnostic value.
Keywords: Diabetes mellitus; dry eye syndromes/diagnosis; Meibomian glands/diagnostic imaging; Meibomian gland dysfunction; type 2/complications
Abstract
Objetivo: Avaliar se as características da tomografia de coerência óptica de domínio espectral dos espaços cistoides intraretinianos prevêem resultados visuais em pacientes que recebem terapia de injeção intravítrea com fator de crescimento endotelial antivascular (bevacizumab 1,25 mg/0,05 ml) para edema macular cistoide diabético.
Métodos: A relação entre as propriedades dos espaços cistoides antes da injeção e os resultados anatômicos e funcionais após a injeção foi investigada em pacientes que receberam três injeções intravítreas para edema macular cistoide. A melhor acuidade visual corrigida para a melhora funcional e a espessura do subcampo central para a melhora anatômica foram avaliadas. Além disso, foi avaliada a relação da localização dos espaços cistoides com a integridade dos fotorreceptores e camadas internas da retina.
Resultados: Em 36 olhos de 36 pacientes, a melhor acuidade visual corrigida foi significativamente aprimorada (p=0,002), e a espessura média do subcampo central foi diminuída após injeções (p=0,003). O aprimoramento da melhor acuidade visual corrigida foi limitado nos olhos com cistos na camada nuclear externa (p=0,045). A reflexividade intracística foi maior nos olhos que falharam na melhor acuidade visual corrigida do que nos olhos com resultados visuais bem-sucedidos (p=0,028). A zona elipsoide interrompida esteve presente em 13 (59,0%) de 22 olhos com cistos na camada nuclear externa, e em apenas 1 de 14 olhos (7,1%) sem cistos na camada nuclear externa (p=0,009). A desorganização das camadas internas da retina esteve presente em 15 dos 22 olhos (68,1%) com cistos na camada nuclear externa, enquanto apenas 2 em 14 olhos (14,2%) sem cistos na camada nuclear externa tiveram desorganização das camadas internas da retina (p=0,013).
Conclusão: Características dos espaços cistoides intrarretinianos podem prever prognóstico em pacientes com edema macular cistoide diabético e ganho visual pode ser limitado nos olhos com cistos na camada nuclear externa.
Keywords: Diabetes Mellitus; Retinopatia diabética; Edema macular; Tomografia de coerência óptica; Espaços cistoides intrarretinianos; Acuidade visual.
Abstract
OBJETIVO: Avaliar as alterações precoces após a primeira injeção de anticorpos antifator de crescimento endotelial vascular (anti-VEGF) em casos de edema macular secundário à retinopatia diabética e oclusão da veia da retina e a relação entre essas alterações e o resultado a longo prazo.
MÉTODOS: Foram incluídos no estudo pacientes que receberam uma injeção de antifator de crescimento endotelial vascular para edema macular, virgem de tratamento e devido à oclusão da veia retiniana ou a retinopatia diabética. A espessura macular central foi medida no início do tratamento e no 1º dia, 2ª semana e 1º mês após a injeção, bem como na última visita, através de tomografia de coerência óptica de domínio espectral. Definiu-se uma “boa resposta” como uma redução ≥10% na espessura macular central no 1º dia após a injeção. Os pacientes foram reavaliados na última visita com relação à resposta ao tratamento no 1º dia após a injeção, com base em um resultado anatômico favorável, definido como uma espessura macular central <350 µm.
RESULTADO: Foram registrados 26 (44,8%) pacientes com edema macular e oclusão da veia da retina e 32 (55,2%) com edema macular e retinopatia diabética. O tempo médio de acompanhamento foi de 24,0 meses (desvio-padrão de 8,5 meses). Foi observada uma diminuição estatisticamente significativa da espessura macular central após o tratamento antifator de crescimento endotelial vascular tanto em pacientes com edema macular e oclusão da veia retiniana quanto naqueles com edema macular e retinopatia diabética (p<0,001 para ambos). Todos os pacientes com edema macular e oclusão da veia retiniana responderam bem no 1º dia pós-injeção. Todos os que responderam mal no 1º dia pós-injeção pertenciam ao grupo com edema macular e retinopatia diabética (n=16,50%). A presença de manchas hiperrefletivas foi maior nos pacientes que responderam mal do que naqueles que tiveram boa resposta no grupo com edema macular e retinopatia diabética (p=0,03). Um dos 42 (2,4%) pacientes com boa resposta total teve espessura macular central >350 µm, enquanto 5 (31,2%) do total de 16 pacientes com resposta ruim apresentaram espessura macular central >350 µm na última visita (p=0,003).
CONCLUSÃO: O resultado anatômico de longo prazo do edema macular secundário à oclusão da veia retiniana e à retinopatia diabética pode ser previsto pela resposta ao tratamento no 1º dia após a injeção de antifator de crescimento endotelial vascular.
Keywords: Edema macular; Retinopatia diabética; Diabetes mellitus; Oclusão da veia retiniana; Fator A de crescimento do endotélio vascular; Inibidores da angiogênese; Resultado do tratamento
Abstract
PURPOSE: To evaluate the accuracy of a short-term intravitreal dexamethasone sodium phosphate challenge in predicting the anatomical response to a sustained-release dexamethasone implant (Ozurdex) in patients with refractory diabetic macular edema.
METHODS: This prospective, non-randomized, Phase 2 pilot study enrolled 12 pseudophakic eyes with diabetic macular edema refractory to anti-vascular endothelial growth factor (anti-VEGF) therapy. Participants underwent a challenge phase (Day 0) consisting of a single intravitreal injection of 0.08-mg dexamethasone sodium phosphate, followed by a maintenance phase (Day 7), during which all subjects received a 0.7-mg dexamethasone implant. The primary outcome was concordance between the anatomical response at Day 3 (post-dexamethasone sodium phosphate) and Day 60 (post-implant), defined as a ≥10% reduction in central macular thickness. Secondary outcomes included achieving a clinically "dry" macula (central macular thickness ≤300 μm) at Day 60, changes in best-corrected visual acuity, safety outcomes (intraocular pressure), and spectral-domain optical coherence tomography biomarker analysis.
RESULTS: The dexamethasone sodium phosphate challenge induced significant macular drying by Day 3 (median central macular thickness reduction, −21 μm; p=0.002). A positive response to dexamethasone sodium phosphate strongly predicted response to the dexamethasone implant, with a positive predictive value and specificity of 100%. The negative predictive
value was 80%. Irreversible biomarkers, including disorganization of retinal inner layers and ellipsoid zone disruption, were more prevalent among nonresponders (60% vs. 28.6%). Safety outcomes were acceptable; 16.7% of patients developed ocular hypertension, which was successfully managed with topical therapy.
CONCLUSION: A short-term dexamethasone sodium phosphate challenge is a safe,
low-cost, and highly specific predictor of dexamethasone implant efficacy. This "test-and-treat" strategy may optimize resource allocation in resource-constrained settings by identifying responders before high-cost implantation.
Keywords: Diabetic retinopathy; Macular edema; Dexamethasone; Drug implants; Biomarkers, pharmacological
Abstract
PURPOSE: This study measured serum hypoxia-inducible factor-1 (HIF-1α) and survivin levels in patients with diabetes and investigated their association with the severity of retinopathy.
METHODS: This study included 88 patients with type 2 diabetes mellitus who underwent routine eye examinations. Three groups were created. Group 1 consisted of patients without diabetic retinopathy. Group 2 included patients with non-proliferative diabetic retinopathy. Group 3 included patients with proliferative diabetic retinopathy. To measure serum HIF-1α and survivin levels, venous blood samples were collected from patients.
RESULTS: The mean HIF-1α levels in groups 1, 2, and 3 were 17.30 ± 2.19, 17.79 ± 2.34, and 14.19 ± 2.94 pg/ml, respectively. Significant differences were detected between groups 1 and 3 (p=0.01) and between groups 2 and 3 (p=0.01). The mean survivin levels in groups 1, 2, and 3 were 42.65 ± 5.37, 54.92 ± 5.55, and 37.46 ± 8.09 pg/ml, respectively. A significant difference was only detected between groups 2 and 3 (p=0.002).
CONCLUSION: The present study revealed that serum HIF-1α and survivin levels are increased in patients with non-proliferative diabetic retinopathy compared to those in patients without diabetic retinopathy.
Keywords: Survivin, HIF-1, Diabetic retinopathy, Hypoxia, Neovascularization
Abstract
PURPOSE: Timely screening and treatment are essential for preventing diabetic retinopathy blindness. Improving screening workflows can reduce waiting times for specialist evaluation and thus enhance patient outcomes. This study assessed different screening approaches in a Brazilian public healthcare setting.
METHODS: This retrospective study evaluated a telemedicine-based diabetic retinopathy screening implemented during the COVID-19 pandemic and compared it with in-person strategies. The evaluation was conducted from the perspective of a specialized referral center in an urban area of Central-West Brazil. In the telemedicine approach, a trained technician would capture retinal images by using a handheld camera. These images were sent to specialists for remote evaluation. Patient variables, including age, gender, duration of diabetes diagnosis, diabetes treatment, comorbidities, and waiting time, were analyzed and compared.
RESULTS: In total, 437 patients with diabetes mellitus were included in the study (mean age: 62.5 ± 11.0 years, female: 61.7%, mean diabetes duration: 15.3 ± 9.7 years, insulin users: 67.8%). In the in-person assessment group, the average waiting time between primary care referral and specialist evaluation was 292.3 ± 213.9 days, and the referral rate was 73.29%. In the telemedicine group, the average waiting time was 158.8 ± 192.4 days, and the referral rate was 29.38%. The telemedicine approach significantly reduced the waiting time (p<0.001) and significantly lowered the referral rate (p<0.001).
CONCLUSION: The telemedicine approach significantly reduced the waiting time for specialist evaluation in a real-world setting. Employing portable retinal cameras may address the burden of diabetic retinopathy, especially in resource-limited settings.
Keywords: Telemedicine/methods; Diabetic retinopathy; Diagnostic screening programs; Vision screening; Practice patterns, physicians
Abstract
OBJETIVO: A diabetes mellitus é considerada uma epidemia global e causa de baixa visual em países em desenvolvimento. Este estudo foi realizado com o objetivo de avaliar a viabilidade do retinógrafo portátil e análise remota de imagens associada a questionário virtual para o rastreio de retinopatia diabética em Unidades Básicas de Saúde da cidade de Ribeirão Preto/SP durante a pandemia de Covid-19.
MÉTODOS: Trezentos e sessenta pacientes compareceram a campanha. O acolhimento foi realizado na Unidade Básica de Saúde pela equipe de enfermagem, respeitando medidas de prevenção do Covid-19 Os realizou-se aferição da pressão arterial e glicemia capilar seguida de dilatação. Dados demográficos e sociais foram coletados através de questionário on-line padronizado via smartphone e realizou-se a triagem da retinopatia diabética através da obtenção de imagens com retinógrafos portáteis realizados por residentes de oftalmologia previamente treinados, com a aquisição de 2 imagens padronizadas de 45o: uma do segmento posterior e outra nasal ao nervo óptico.
RESULTADOS: Trezentos e sessenta pacientes foram atendidos durante a campanha. Dez pacientes (1,02%) foram excluídos devido à opacidade de meios e impossibilidade de obtenção de imagens de fundo de olho. Foram avaliados 350 pacientes, 64% do sexo feminino, 45% entre 55 e 70 anos e 55% brancos. A Campanha foi a primeira avaliação de retina para 40,5% dos pacientes e 47,56% apresentavam diabetes mellitus há mais de 10 anos. Na análise comparativa da classificação da retinopatia diabética segundo Early Treatment Diabetic Retinopathy Study (triagem X Nuvem) observou-se uma diferença de 7,8% nos resultados. Retinopatia diabética leve foi observada em 12,23%, moderada em 6,31%, proliferativa em 2,58%; edema macular presente em 4,58% e ausência de retinopatia diabética em 72,78% dos pacientes.
CONCLUSÃO: A utilização de retinógrafos portáteis juntamente a telemedicina, para o rastreamento da retinopatia diabética pode ser considerada uma alternativa eficiente para triagem e diagnóstico da retinopatia diabética dentro ou fora do cenário pandêmico, auxiliando na prevenção de perda visual pelo diabetes.
Keywords: Retinopatia diabética/diagnóstico; Covid-19; Retina/diagnóstico por imagem; Oftalmologia/instrumentação; Oftalmoscópicos; Sistemas automatizados de assistência junto ao leito; Telemedicina/métodos
Abstract
Um homem de 42 anos apresentou uma massa na conjuntiva palpebral inferior direita, próxima ao punctum, com evolução de 4 semanas. Uma biópsia excisional da lesão e o subsequente exame anatomopatológico revelaram que a massa era composta de células de Schwann com núcleos cônicos, cromatina fina e nucléolos não visíveis. Ao exame imuno-histoquímico, as células fusiformes mostraram-se difusa e fortemente positivas para a proteína S100. A imunocoloração também foi positiva para neurofilamentos e evidenciou os axônios. Considerando esses achados, o tumor foi diagnosticado como um neuroma circunscrito solitário. Procedeu-se uma investigação completa para neoplasia endócrina múltipla tipo 2b, entretanto, estigmas característicos e história familiar não foram detectados. Assim, o diagnóstico foi firmado como neuroma circunscrito solitário, condição rara cujo diagnóstico diferencial baseia-se no exame anatomopatológico e na avaliação imuno-histoquímica. Já que esse tumor pode estar relacionado à neoplasia endócrina múltipla tipo 2b, torna-se essencial, nesses casos, a investigação da neoplasia de forma sistemática.
Keywords: Neuroma; Neoplasia endócrina múltipla tipo 2b; Neoplasias da túnica conjuntiva; Diagnostico diferencial; Humanos; Relatos de casos
ABO is licensed under a Creative Commons Attribution-NonComercial 4.0 Internacional.
About
Issues
Editorial Board
Submission
Official publication of Conselho Brasileiro de Oftalmologia
Rua Casa do Ator, 1.117 - 2º andar - CEP: 04546-004
São Paulo - SP, Brazil
Phone: +55 11 3266-4000