Showing of 1 until 15 from 283 result(s)
Search for: Glaucoma; Intraocular pressure; Nerve fibers; Retina; Diagnostic techniques; ophthalmological; Lasers
Abstract
Objetivo: Investigar picos de pressão intraocular em pacientes fácicos e pseudofácicos com glaucoma primário de ângulo aberto no teste de sobrecarga hídrica.
Método: Quarenta pacientes com glaucoma primário de ângulo aberto foram avaliados; vinte eram fácicos e vinte eram pseudofácicos. Um olho (selecionado aleatoriamente) foi incluído no estudo, todos os pacientes foram submetidos às curvas da pressão intraocular imediatamente após o teste de sobrecarga hídrica.
Resultados: Observou-se uma diferença estatisticamente significante na média dos picos nas curvas da pressão intraocular para os pacientes fácicos e pseudofácicos (p=0,045). Houve diferença estatisticamente significante nos picos da pressão intraocular no teste de sobrecarga hídrica entre os grupos, sendo observados valores mais altos nos pacientes fácicos (p=0,004).
Conclusão: Os picos da pressão intraocular no teste de sobrecarga hídrica foram maiores no grupo fácico que no grupo pseudofácico.
Keywords: Glaucoma de ângulo aberto; Técnicas de diagnóstico oftalmológico; Água potável; Pressão intraocular
Abstract
Objetivo: Investigar a correlação entre a hemodinâmica arterial, medida pela ultrassonografia com Doppler colorido, e os parâmetros de microarquitetura da retina, determinados pela tomografia de coerência óptica de domínio espectral (SD-OCT) no glaucoma pseudoexfoliativo.
Métodos: Foram incluídos 82 participantes neste estudo prospectivo. Foram medidos os valores da camada de fibras nervosas da retina peripapilar, da camada plexiforme interna de células ganglionares e do complexo de células ganglionares. Os fluxos da artéria oftálmica e da artéria central da retina foram avaliados com ultrassonografia por Doppler colorida e foram calculados os valores do índice de resistividade.
Resultados: Foram incluídos no estudo 47 casos de controle e 35 casos de glaucoma pseudoexfoliativo. No grupo com glaucoma pseudoexfoliativo, a média da camada de fibras nervosas da retina peripapilar e a espessura do complexo de células ganglionares foram menores em todos os quadrantes em comparação com os controles, com significância estatística (p<0,001). Os valores do índice de resistividade das artérias oftálmica e central da retina foram significativamente maiores no grupo com glaucoma pseudoexfoliativo que nos controles (p<0,001 e r=0,684). Ao se compararem os valores do índice de resistividade das artérias oftálmica e central da retina com a espessura do complexo de células ganglionares, foi encontrada uma correlação significativa entre elas. Por outro lado, não detectamos uma relação significativa para a espessura da camada de fibras nervosas da retina.
Conclusões: Alterações estruturais (complexo de células ganglionares, camada plexiforme interna de células ganglionares) em pacientes com glaucoma pseudoexfoliativo com perda glaucomatosa precoce mostraram uma correlação significativa com alterações na hemodinâmica vascular ocular. Nos casos em que a resistência vascular sistêmica é aumentada, o complexo de células ganglionares e a camada plexiforme interna de células ganglionares podem não refletir exatamente o estado do glaucoma. Nesses casos, alterações na espessura da camada de fibras nervosas da retina podem dar resultados mais realistas em relação ao glaucoma. Observou-se uma correlação da deterioração estrutural induzida pelo glaucoma pseudoexfoliativo e do aumento da resistência na hemodinâmica ocular com o complexo de células ganglionares, mas não com a camada de fibras nervosas da retina.
Keywords: Artéria retiniana; Tomografia de coerência óptica; Artéria oftálmica; Fibras nervosas; Glaucoma; Ultrassonografia doppler em cores; Resistência vascular; Hemodinâmica; Células ganglionares da retina.
Abstract
PURPOSE: This study aimed to compare the safety and effectiveness of intraocular pressure reduction between micropulse transscleral cyclophotocoagulation and “slow cook” transscleral cyclophotocoagulation in patients with refractory primary open-angle glaucoma.
METHODS: We included patients with primary open angle glaucoma with at least 12 months of follow-up. We collected and analyzed data on the preoperative characteristics and postoperative outcomes. The primary outcomes were a reduction of ≥20% of the baseline value (criterion A) and/or intraocular pressure between 6 and 21 mmHg (criterion B).
RESULTS: We included 128 eyes with primary open-angle glaucoma. The preoperative mean intraocular pressure was 25.53 ± 6.40 and 35.02 ± 12.57 mmHg in the micropulse- and “slow cook” transscleral cyclophotocoagulation groups, respectively (p<0.001). The mean intraocular pressure was reduced significantly to 14.33 ± 3.40 and 15.37 ± 5.85 mmHg in the micropulse- and “slow cook” transscleral cyclophotocoagulation groups at the last follow-up, respectively (p=0.110). The mean intraocular pressure reduction at 12 months was 11.20 ± 11.46 and 19.65 ± 13.22 mmHg in the micropulse- and “slow cook” transscleral cyclophotocoagulation groups, respectively (p<0.001). The median preoperative logMAR visual acuity was 0.52 ± 0.69 and 1.75 ± 1.04 in the micropulse- and “slow cook” transscleral cyclophotocoagulation groups, respectively (p<0.001). The mean visual acuity variation was -0.10 ± 0.35 and -0.074 ± 0.16 in the micropulse- and “slow cook” transscleral cyclophotocoagulation, respectively (p=0.510). Preoperatively, the mean eye drops were 3.44 ± 1.38 and 2.89 ± 0.68 drugs in the micropulse- and “slow cook” transscleral cyclophotocoagulation groups, respectively (p=0.017), but those were 2.06 ± 1.42 and 1.02 ± 1.46 at the end of the study in the slow cook” and micropulse transscleral cyclophotocoagulation groups, respectively (p<0.001). The success of criterion A was not significant between both groups. Compared with 11 eyes (17.74%) in the slow cook” transscleral cyclophotocoagulation group, 19 eyes (28.78%) in the micropulse transscleral cyclophotocoagulation group showed complete success (p=0.171). For criterion B, 28 (42.42%) and 2 eyes (3.22%) showed complete success after micropulse- and slow cook” transscleral cyclophotocoagulation, respectively (p<0.001).
CONCLUSION: Both techniques reduced intraocular pressure effectively.
Keywords: Sclera/surgery; Glaucoma, open-angle/surgery; Ciliary body/surgery; Intraocular pressure; Laser coagulation/methods; Lasers, semiconductor; Comparative study; Effectiveness
Abstract
Objetivo: Numerosos estudos de neuroimagem e oftalmologia sugerem o acometimento do nervo óptico na síndrome de fibromialgia. Para esclarecer a etiopatogenia da síndrome de fibromialgia, comparamos a área de fluxo sanguíneo da cabeça do nervo óptico e a espessura da camada de fibras nervosas da retina entre pacientes e o grupo controle, e examinamos as associações dessas medidas com a severidade da síndrome de fibromialgia.
Métodos: Os participantes foram divididos em três grupos de acordo com a pontuação no Questionário de Impacto da Fibromialgia: síndrome de fibromialgia leve a moderada (Grupo 1, n=47), síndrome de fibromialgia grave (Grupo 2, n=38) e controles saudáveis (Grupo 3, n=38). A área de fluxo sanguíneo da cabeça do nervo óptico e a espessura da camada de fibras nervosas da retina foram medidas por angiotomografia de coerência óptica e comparadas entre os grupos por ANOVA. As associações com a severidade da síndrome de fibromialgia foram avaliadas pela análise de correlação de Spearman.
Resultados: A área de fluxo sanguíneo da cabeça do nervo óptico não diferiu entre os Grupos 1 e 2 da síndrome de fibromialgia (1,61 ± 0,08 contra 1,63 ± 0,09 mm2), mas foi significativamente menor no Grupo 3, de controle (1,49 ± 0,10 mm2, todos com p=0,001). Os valores médios da espessura da camada de fibras nervosas da retina foram significativamente menores no Grupo 2 (101,18 ± 6,03 µm) em comparação com o Grupo 1 (103,21 ± 10,66 µm) e o Grupo 3 (106,51 ± 8,88 µm) (p=0,041, p=0,020). Os valores da espessura da camada de fibras nervosas no quadrante inferotemporal (134,36 ± 12,19 µm) e inferonasal (109,47 ± 16,03 µm) foram significativamente menores no Grupo 2 em comparação com o Grupo 1 (inferotemporal 142,15 ± 17,79 µm, inferonasal 117,94 ± 20,53 µm) e o Grupo 3 (inferotemporal 144,70 ± 16,25 µm, inferonasal 118,63 ± 19,01 µm) Para o quadrante inferotemporal, foram obtidos p=0,017 e p=0,010 para o Grupo 2 em comparação respectivamente com os Grupos 1 e 3, e para o quadrante inferonasal, p=0,047 e p=0,045, respectivamente para os mesmos grupos. A espessura da camada de fibra nervosa da retina no quadrante nasal superior foi maior no Grupo 3 (91,08 ± 12,11 µm) que no Grupo 1 (84,34 ± 13,09 µm) e no Grupo 2 (85,26 ± 13,11 µm); p=0,031 e p=0,038. Houve uma correlação fraca entre a severidade da doença e a área de fluxo sanguíneo na cabeça do nervo óptico.
Conclusão: As estruturas neurais e vasculares do olho estão alteradas na síndrome da fibromialgia, principalmente nos casos graves. Assim, a angiografia por tomografia de coerência óptica pode fornecer informações valiosas para o diagnóstico e elucidação da fisiopatologia da síndrome de fibromialgia.
Keywords: Fibromialgia; Tomografia de coerência óptica; Angiografia; Nervo óptico/irrigação sanguínea; Fibras nervosas; Retina
Abstract
Objetivos: Procuramos avaliar o uso da pupilometria estática e dinâmica quantitativa automatizada na triagem de pacientes com diabetes mellitus tipo 2 e em diferentes estágios de retinopatia diabética.
Métodos: Cento e cinquenta e cinco pacientes com diabetes mellitus tipo 2 (grupo com diabetes mellitus) foram incluídos neste estudo e outros 145 controles saudáveis pareados por idade e sexo para server como grupo controle. O grupo com diabetes mellitus foi dividido em três subgrupos: diabetes mellitus sem retinopatia diabética (retinopatia não diabética), retinopatia diabética não proliferativa e retinopatia diabética proliferativa. A pupilometria estática e dinâmica foi realizada utilizando uma camera rotative Scheimpflug com um sistema baseado em topografia.
Resultados: Em termos de diâmetro da pupila, tanto na pupilometria estática quanto na dinâmica (p<0,05), foram observadas diferenças estatisticamente significantes entre os grupos diabetes mellitus e controle e também entre os subgrupos retinopatia não diabética, retinopatia diabética não proliferativa e retinopatia diabética proliferativa. Mas foi observado que os grupos de retinopatia não diabética e retinopatia diabética não proliferativa mostraram semelhanças nos achados derivados da pupilometria estática em condições mesópicas e fotópicas. Os dois grupos também pareciam semelhantes em todos os pontos durante a pupilometria dinâmica (p>0,05). No entanto, pode-se concluir que o grupo de retinopatia diabética proliferative foi sugnificativamente diferente do restante dos subgrupos, retinopatia não diabética e retinopatia diabética não proliferativa, em termos de todas as medidas de pupilometris estática (p<0,05). A velocidade média de dilatação também foi significativamente diferente entre os grupos diabetes mellitus e controle, e entre os subgrupos diabetes mellitus (p<0,001). Enquanto correlações significativas fracas a moderadas foram encontradas entre todos os diâmetros da pupila na pupilometria estática e dinâmica com a duração do diabetes mellitus (p<0,05 para todos), os valores de HbA1c não mostraram correlações estatisticamente significantes com nenhum dos diâmetros da pupila estática e dinâmica investigados (p>0,05 para todos).
Conclusão: Este estudo revelou que as medidas derivadas da pupilometria automatizada estão alteradas em pacientes com diabetes mellitus tipo 2. A presença de retinopatia diabética não proliferativa não afeta negativamente os achados pupilométricos, mas com a retinopatia diabética proliferative, alterações significativas foram observadas. Estes resultados sugerem que o uso da pupilometria quantitativa automatizada pode ser útil na verificação gravidade da retinopatia diabética.
Keywords: Retinopatia diabética; Diabetes Mellitus; Técnicas de diagnóstico oftalmológico; Pupila; Reflexo pupilar
Abstract
Objetivo: Fornecer orientações sobre a frequência e os componentes dos exames oftalmológicos para crianças saudáveis de 0 a 5 anos.
Métodos: Essas diretrizes foram desenvolvidas com base em revisão bibliográfica e experiência clínica de um comitê de especialistas. Foram realizadas buscas PubMed/Medline; documentos selecionados não se restringiram a revisões sistemáticas, ensaios clínicos randomizados e estudos observacionais. Quando adequado, o perfil GRADE foi aplicado para graduá-los e o consenso de especialistas foi usado nos tópicos sem evidência científica. Também foram revisadas as recomendações pela Academia Americana de Pediatria, Associação Americana de Oftalmologia Pediátrica e Estrabismo, Academia Americana de Oftalmologia, Royal College of Ophthalmologist e Sociedade Canadense de Oftalmologia. O documento final foi aprovado pela Sociedade Brasileira de Oftalmologia Pediátrica e Sociedade Brasileira de Pediatria.
Resultados: Os recém-nascidos devem ser submetidos ao teste do reflexo vermelho e inspeção dos olhos e anexos pelo pediatra dentro de 72 horas de vida ou antes da alta da maternidade. O teste do reflexo vermelho deve ser repetido pelo pediatra durante as consultas de puericultura pelo menos três vezes ao ano durante os primeiros 3 anos de vida. Se factível, um exame oftalmológico completo pode ser feito entre 6 a 12 meses de vida. Até os 36 meses de idade, os marcos visuais, função visual apropriada para a idade, fixação e alinhamento ocular também devem ser avaliados pelo pediatra ou médico da família. Pelo menos um exame oftalmológico completo deve ser realizados entre 3 e 5 anos de idade. O exame deve conter pelo menos inspeção dos olhos e anexos, avaliação da função visual apropriada para a idade, avaliação da motilidade e alinhamento ocular (testes de cobertura), refração sob cicloplegia e avaliação do fundo de olho dilatado.
Conclusões: As diretrizes sobre a frequência da avaliação oftalmológica são ferramentas importantes para orientar os médicos sobre a melhor prática a fim de evitar problemas visuais tratáveis na infância, que poderiam comprometer seu desenvolvimento social, escolar e global, além de causar perda permanente da visão.
Keywords: Técnicas de diagnóstico oftalmológico, Triagem visual; Testes visuais; Criança, Lactente
Abstract
PURPOSE: Glaucoma is one of the leading causes of irreversible blindness worldwide. When topical hypotensive agents or laser trabeculoplasty fail to adequately control the disease, escalation of therapy becomes necessary, with transscleral cyclophotocoagulation being one of the available options. Several variations of transscleral cyclophotocoagulation exist, including traditional continuous wave, MicroPulse, and slow-coagulation techniques. We propose a novel variation – custom slow-coagulation transscleral cyclophotocoagulation – which combines elements of both continuous wave and slow-coagulation approaches. This study aimed to evaluate the outcomes of this technique in patients with refractory glaucoma.
METHODS: This retrospective, interventional study included 104 eyes of 83 patients with refractory glaucoma who underwent custom slow-coagulation transscleral cyclophotocoagulation. Changes in intraocular pressure, visual acuity, the number of glaucoma medications, and postoperative complications were analyzed. A paired t test was used to compare changes in intraocular pressure and visual acuity, while the Wilcoxon signed-rank test was applied to categorical variables. Success rates following custom slow-coagulation transscleral cyclophotocoagulation were estimated using Kaplan–Meier survival analysis.
RESULTS: Mean intraocular pressure decreased significantly from 38.9 ± 15.8 mmHg at baseline to 16.3 ± 9.9 mmHg at Month 12 (p<0.001). The mean number of glaucoma medications also decreased significantly from 3.6 ± 0.6 to 1.8 ± 1.4 (p<0.001). No significant reduction in mean visual acuity was observed during follow-up.
CONCLUSIONS: Custom slow-coagulation transscleral cyclophotocoagulation effectively reduced baseline intraocular pressure and the number of glaucoma medications, with a low rate of complications and no decline in visual acuity over a 12-month follow-up period. This novel technique demonstrated a high safety profile in a Hispanic population and represents a low-cost, minimally invasive procedure with rapid recovery and promising efficacy in intraocular pressure control.
Keywords: Glaucoma/surgery; Sclera; Filtering surgery; Laser coagulation/methods; Lasers, semiconductor/therapeutic use; Intraocular pressure; Blindness/prevention & control; Vision, low/epidemiology; Visual acuity
Abstract
OBJETIVO: Glaucoma é a principal causa de cegueira irreversível no mundo. O pico da pressão intraocular é um dos principais fatores de risco para progressão do glaucoma, e o controle pressórico ainda é o único tratamento efetivo para todas as formas de glaucoma. O objetivo principal deste estudo é comparar a redução basal e do pico da pressão intraocular, obtidas através do Teste de Sobrecarga Hídrica, entre os dois olhos dos mesmos pacientes utilizando latanoprosta 0,005% em um olho e submetidos à aplicação de trabeculoplastia a laser seletiva no olho contralateral.
MÉTODOS: Este é um estudo prospectivo, intervencionista, longitudinal e randomizado. Trinta pacientes consecutivos, glaucomatosos, com pressão intraocular controlada em uso de monoterapia com latanoprosta, foram recrutados de um único centro oftalmológico. Os olhos dos pacientes foram randomizados e um olho foi selecionado para tratamento com trabeculoplastia a laser seletiva e olho contralateral tratado com colírio de latanoprosta 0,005%. Foram avaliados a pressão intraocular basal e pico de pressão intraocular um mês (Teste de Sobrecarga Hídrica 2) e seis meses (Teste de Sobrecarga Hídrica 3) após tratamento.
RESULTADOS: Não houve diferença estatística entre a pressão intraocular pré washout entre os olhos randomizados para trabeculoplastia a laser seletiva e latanoprosta, 13,6 ± 2,1 e 13,3 ± 1,8 mmHg, respectivamente (p=0,182). Em relação à pressão intraocular basal, não houve diferença estatística entre os grupos, tanto no Teste de Sobrecarga Hídrica 2 (p=0,689) e Teste de Sobrecarga Hídrica 3 (p=0,06). Não houve diferença estatística em relação ao pico de pressão intraocular entre os grupos trabeculoplastia a laser seletiva e latanoprosta, no Teste de Sobrecarga Hídrica 2 (p=0,771) e Teste de Sobrecarga Hídrica 3 (p=0,774).
CONCLUSÕES: Em resumo, nosso estudo demonsrou que a eficácia da redução pressórica é similar entre latanoprosta e trabeculoplastia a laser seletiva, e pacientes glaucomatosos que estão com a pressão intraocular clinicamente controlados com latanoprosta e trocam de tratamento para trabeculoplastia a laser seletiva mantém sua pressão intraocular controlada.
Keywords: Glaucoma; Pressão intraocular; Latanoprosta; Lasers
Abstract
OJETIVOS: O olho seco é uma doença multifatorial, muito comum na prática clínica oftalmológica. A utilização de questionários validados de sintomas de olho seco permite rastrear de maneira mais objetiva essa doença na população geral, avaliar a prevalência dos sintomas e frequência de diagnóstico, permitindo o tratamento precoce e adequado dessa condição. O 5-Item Dry Eye Questionnaire (DEQ-5) é um questionário em inglês que avalia a frequência e a intensidade do desconforto e ressecamento ocular e a frequência do lacrimejamento, já validado no inglês e espanhol, porém não no português até o presente momento. O objetivo deste estudo foi traduzir e validar o questionário DEQ-5 para a língua portuguesa.
MÉTODOS: Foi utilizado o questionário DEQ-5, composto por 5 perguntas simples e diretas - 2 relacionadas ao desconforto ocular, 2 ao ressecamento ocular e 1 ao lacrimejamento. Foi realizada a tradução inicial da versão em inglês para o português por dois tradutores de língua materna portuguesa, seguido de uma avaliação e compilação de uma versão única por um comitê interdisciplinar das versões traduzidas. Em seguida, tal versão foi traduzida de volta para o inglês por 2 indivíduos que possuíam o inglês como primeira língua, seguido de avaliação e comparação com a versão original em língua inglesa pelo mesmo comitê interdisciplinar. Após, a versão final do questionário foi aplicada em 31 voluntários em dois momentos diferentes.
RESULTADOS: A confiabilidade interobservador das 5 perguntas variou de 0,584-0,813 e a correlação de Pearson de 0.755-0.935, sendo o p-valor <0,0001 em todas elas. A consistência interna foi α=0,887. Todas as perguntas apresentaram concordância de moderada a alta.
CONCLUSÕES: A análise estatística dos dados coletados encontrou ótimos índices de concordância - moderada a alta para todas as questões analisadas -, permitindo o uso do DEQ-5 na língua portuguesa em pesquisas e também como forma de triagem para doença de olho seco e acompanhamento dos sintomas.
Keywords: Síndromes do olho seco; Técnicas de diagnóstico oftalmológico; Inquéritos e questionários; Traduções
Abstract
PURPOSE: To quantitatively assess changes in central corneal sensitivity after phacoemulsification and to characterize recovery patterns up to 90 days using standardized esthesiometry.
METHODS: This prospective observational study included 44 patients (88 eyes) undergoing uncomplicated phacoemulsification with intraocular lens implantation. Central corneal sensitivity was measured using a Cochet-Bonnet® esthesiometer preoperatively and at 30 and 90 days postoperatively. Repeated-measures data were analyzed using Friedman and Wilcoxon signed-rank tests (p<0.05). Inter-eye differences were assessed with a paired Wilcoxon test. Individual changes from baseline (Δ30, Δ90) were calculated, and 90-day recovery was categorized according to thresholds aligned with the 5-mm device resolution. Spearman correlation was used to explore associations between age and Δ90.
RESULTS: Corneal sensitivity decreased after surgery. In right eyes, mean sensitivity declined from 41.14 ± 7.77 mm at baseline to 36.82 ± 9.03 mm at 30 days and partially recovered to 38.64 ± 7.73 mm at 90 days. In left eyes, sensitivity decreased from 44.11 ± 6.29 mm to 37.39 ± 9.05 mm at 30 days and recovered to 41.82 ± 7.63 mm at 90 days. Left eyes showed higher sensitivity than right eyes at baseline (p=0.023) and at 90 days (p=0.018). At 90 days, complete or near-complete recovery (within ± 5 mm of baseline) occurred in 73.2% of right eyes and 78.0% of left eyes, while improvement above baseline (≥ +5 mm) occurred in 7.3% and 4.9%, respectively. Age showed weak, nonsignificant correlations with Δ90 (p=−0.14 to −0.19; p>0.2).
CONCLUSION: Phacoemulsification with a 2.75-mm clear corneal incision leads to a temporary reduction in central corneal sensitivity, with partial recovery by 90 days. Recovery patterns vary among individuals, highlighting the value of postoperative sensitivity monitoring to identify atypical trajectories and guide ocular surface care during visual rehabilitation.
Keywords: Phacoemulsification; Cornea/innervation; Ophthalmic nerve/physiology; Optometry/instrumentation; Diagnostic techniques, ophthalmological; Neural regeneration; Visual rehabilitation.
Abstract
Objetivo: A possível variabilidade nos resultados de testes diagnósticos é uma característica estatística dos pacientes com síndrome do olho seco. O médico deve considerar as variações do filme lacrimal ao longo do tempo, pois o momento em que o filme lacrimal é medido pode ser crítico para o diagnóstico adequado. O objetivo deste estudo foi analisar a variação semanal da osmolaridade do filme lacrimal em participantes saudáveis e em outros com síndrome do olho seco.
Métodos: Com base nos critérios da metodologia de diagnóstico do relatório da Dry Eye Workshop II (DEWSII), foi aplicada uma bateria de testes (questionário do índice de doença da superfície ocular [OSDI], tempo de ruptura do filme lacrimal e coloração da córnea) para descartar a presença de síndrome do olho seco. Um total de 40 voluntários qualificados foi recrutado e distribuído em dois grupos de 20 participantes saudáveis e 20 participantes com síndrome do olho seco. A variação da osmolaridade entre semanas foi medida com um osmômetro TearLab em duas sessões com uma semana de intervalo nos dois grupos. As diferenças entre os resultados foram então calculadas.
Resultados: Não foram encontradas diferenças significativas na osmolaridade entre as medidas obtidas nas duas sessões, nem no grupo de participantes saudáveis (teste de t pareado; p=0,085), nem no de participantes com síndrome do olho seco (teste de t pareado; p=0,093). Não foi detectada nenhuma correlação significativa entre as médias e diferenças entre as duas sessões entre participantes saudáveis (correlação de Pearson: r=0,020, p=0,935) e aqueles com síndrome do olho seco (correlação Pearson: r=-0,022, p=0,928). Foi encontrada uma diferença significativa nos valores de osmolaridade entre os dois grupos na primeira sessão (teste de t não pareado; p=0,001), mas nenhuma diferença foi encontrada na segunda sessão (teste de t não pareado; p=0,292).
Conclusões: O presente estudo não encontrou variação entre semanas consecutivas na osmolaridade do filme lacrimal em participantes saudáveis e com síndrome do olho seco, classificados com base nos critérios do DEWSII.
Keywords: Concentração osmolar; Lágrimas; Síndromes do olho seco; Técnicas de diagnóstico oftalmológico
Abstract
Os benzodiazepínicos são medicamentos psicoativos prescritos em todo o mundo, mas com poucas informações sobre seus efeitos colaterais oculares. O glaucoma por fechamento agudo do ângulo iridocorneano é um dos eventos adversos com maior risco de cegueira, sendo descrito particularmente em idosos. Relatamos aqui dois pacientes com menos de 45 anos de idade, com fechamento agudo do ângulo bilateral secundário ao uso de dois diferentes benzodiazepínicos de meia-vida longa (clonazepam e alprazolam). Além da suspensão dessas medicações e do tratamento clínico com drogas hipotensoras oculares, ambos os casos alcançaram sucesso com iridotomias periféricas bilaterais à laser. Considerando o conhecimento atual, estes são os primeiros relatos de fechamento agudo do ângulo bilateral secundária ao uso de clonazepam e alprazolam.
Keywords: Benzodiazepinas/efeitos adversos; Glaucoma de ângulo fechado/ induzido quimicamente; Iridectomia; Lasers
Abstract
A cicloplegia é crucial para um exame oftalmológico pediátrico acurado. Este documento visa a fornecer uma recomendação para cicloplegia e midríase pediátrica para oftalmologistas brasileiros. Foi desenvolvido com base em revisão literária, na experiência clínica de especialistas brasileiros, por meio de questionários, e no consenso do comitê de especialistas da Sociedade Brasileira de Oftalmologia Pediátrica (SBOP). De acordo com as melhores evidências, este comitê recomenda o uso de uma gota de ciclopentolato 1%, mais uma gota de tropicamida 1% em crianças maiores de 6 meses e duas gotas de tropicamida 1% com intervalo de 0-5 minutos para menores de 6 meses. A midríase pode ser potencializada por uma gota de fenilefrina 2,5%. Para o rastreamento da retinopatia da prematuridade, a recomendação é tropicamida 0,5 ou 1%, duas ou três vezes, com 5 minutos de intervalo, e 2,5% de fenilefrina, preferencialmente uma vez. O uso prévio de proxymetacaína 0,5% é sempre recomendado.
Keywords: Midríase; Refração ocular; Recém-nascido; Criança; Técnicas de diagnóstico oftalmológico.
Abstract
A young woman presented at our clinic with sudden visual loss in the right eye, recurrent vertigo, and right-sided tinnitus. We performed a complete ophthalmological evaluation. This revealed effects of the condition on the small arterioles of the peripheral retina. Susac syndrome is characterized by the clinical triad of retinal arteriolar occlusions, cochleovestibular manifestations, and encephalopathy (which can be identified by neuroimaging abnormalities). Early diagnosis and immunosuppressive therapy improved the patient’s visual acuity and the remission of her other symptoms. Hemi-central retinal artery occlusion is an atypical neuro-ophthalmological finding in this disease. However, its identification as a sign of Susac syndrome may facilitate timely diagnosis and accurate treatment.
Keywords: Ophthalmological diagnostic techniques; Retinal artery occlusion; Vertigo; Cerebrovascular disorders; Susac syndrome
Abstract
Repeat selective laser trabeculoplasty has emerged as a valuable option for managing intraocular pressure in patients with primary open-angle glaucoma or ocular hypertension. This review synthesizes current evidence of the efficacy, safety, and clinical applicability of repeat selective laser trabeculoplasty. Evidence from randomized controlled trials, systematic reviews, and observational studies indicate that repeat selective laser trabeculoplasty effectively sustains significant intraocular pressure reduction with minimal complications. This procedure demonstrates comparable efficacy to that of initial selective laser trabeculoplasty, supporting its role as a sustainable, drop-free management strategy. However, further research is warranted to optimize treatment intervals, assess long-term outcomes, and evaluate cost-effectiveness across different healthcare settings.
Keywords: Glaucoma; Ocular hypertension; Intraocular pressure; Selective laser trabeculoplasty
ABO is licensed under a Creative Commons Attribution-NonComercial 4.0 Internacional.
About
Issues
Editorial Board
Submission
Official publication of Conselho Brasileiro de Oftalmologia
Rua Casa do Ator, 1.117 - 2º andar - CEP: 04546-004
São Paulo - SP, Brazil
Phone: +55 11 3266-4000