Antonio Eduardo Pereira1; Ana Cláudia Alves Pereira2; Marcos Pereira Ávila3
DOI: 10.1590/S0004-27492008000500016
ABSTRACT
PURPOSE: To compare the 14% and 67% duty cycles of ultrasound power, continuous module, manual pulse control in the Sovereign® phacoemulsification system with WhiteStarTM power modulation for cataract surgery. The phacoemulsification nuclear preslice technique was used to evaluate effective ultrasound time, ultrasound percentage, salt solution amount and endothelial cell loss. METHODS: This was a prospective and comparative clinical trial in 32 patients (38 eyes) with senile nuclear cataract NO3 NC3 and NO4 NC4 (LOCS III) divided into two groups: A and B. To perform the cataract surgery phacoemulsification with nuclear preslice technique, manual pulse control was used; for group A with 14% duty cycle (n=21) and group B with 67% duty cycle (n=17). Both groups were subdivided according to crystalline opaque level in two subgroups. Preoperative measures included complete ophthalmologic examination, biometry, pachymetry and specular microscopy and 3 months after surgery specular microscopy. RESULTS: The surgeries that were used with the 67% duty cycle had significantly more ultrasound effective time than the 14% group in more dense cataracts. The ultrasound percentage in the 67% duty cycle, in different cataract densities, was significantly higher than in the 14% duty cycle. There was no difference in the salt solution amount used in the surgeries. There was no statistically significant difference of endothelial cell loss between both ultrasound cycles. There was a statistically significant correlation between the endothelial cell loss and the variables: ultrasound effective time (EPT) and salt solution amount used in surgeries in both cycles. CONCLUSIONS: This clinical trial showed less effective time of ultrasound and ultrasound percentage in the 14% duty cycle for more dense cataracts. The salt solution amount used and the endothelial cell loss were the same in both cycles. The ultrasound effective time and the salt solution amount used in the surgery were correlated to endothelial cell loss.
Keywords: Phacoemulsification; Cataract extraction; Prospective studies; Endothelial cells; Visual acuity; Comparative study
RESUMO
OBJETIVOS: Comparar os ciclos de 14% e 67% de ultra-som ligado, módulo contínuo, e controle manual do pulso, no aparelho Sovereign® com sistema WhiteStarTM, para a cirurgia de catarata, utilizando-se a técnica de facoemulsificação "nuclear preslice" nos quesitos: tempo efetivo de ultra-som, porcentual de ultra-som, volume de solução salina e perda de células endoteliais. MÉTODOS: Estudo prospectivo, comparativo de 32 pacientes (38 olhos), com catarata nuclear senil NO3NC3 e NO4NC4 (LOCS III), randomizados em dois grupos, nos quais foi realizada a facoemulsificação com a técnica "nuclear preslice" e controle de pulso manual. No pré-operatório foram realizados: exame oftalmológico completo, biometria, paquimetria central corneana e microscopia especular. No pós-operatório foram avaliados, nas primeiras 24 horas após a cirurgia, a acuidade visual e paquimetria central corneana e, após 3 meses, realizada a microscopia especular. RESULTADOS: As cirurgias com ciclo 67% apresentaram tempo efetivo de ultra-som significantemente maior do que as cirurgias pelo ciclo 14%, em cataratas mais densas. O porcentual de ultra-som no ciclo 67%, em diferentes densidades de cataratas, foi significantemente maior do que no ciclo 14%. Não houve diferenças quanto ao volume de solução salina utilizado nas cirurgias. Não se observou diferença significante na perda de células endoteliais nos diferentes ciclos de ultra-som. Houve correlação positiva significante entre a perda de células endoteliais e as variáveis: tempo efetivo de ultra-som e volume de solução salina utilizado, em ambos os ciclos. CONCLUSÕES: O tempo efetivo e o porcentual de ultra-som foram menores nas cirurgias com ciclo de ultra-som 14%, em cataratas mais densas. O volume de solução salina utilizado e a perda de células endoteliais foram semelhantes em ambos os ciclos. O tempo efetivo de ultra-som e o volume de solução salina foram correlacionados à maior perda de células endoteliais.
Descritores: Facoemulsificação; Extração de catarata; Estudos prospectivos; Células endoteliais; Acuidade visual; Estudo comparativo
THE CONTENT OF THIS ARTICLE IS NOT AVAILABLE FOR THIS LANGUAGE.