Abstract
Objetivo: Avaliar a qualidade óptica medindo o índice de dispersão objetiva de luz e os parâmetros de qualidade óptica objetiva (Razão de Strehl e Função de Transferência de Modulação) em indivíduos com emetropia e ametropia.
Métodos: Estudo prospectivo, transversal, incluindo 408 olhos. O grupo ametrópico era de olhos com melhor acuidade visual corrigida de 0,0 logMAR ou melhor e apresentando, pelo menos, um erro refrativo de 0,25 D ou mais. Os pacientes foram submetidos a exame com lâmpada de fenda, acuidade visual, refração e qualidade óptica com o HD Analyzer.
Resultados: O índice de dispersão objetiva de luz médio foi de 0,62 ± 0,63, 0,77 ± 0,70, 0,74 ± 0,30, 0,93 ± 0,55, 0,85 ± 0,61 e a média da Razão de Strehl e de Função de Transferência de Modulação foram 38,17 ± 10,4, 37,37 ± 10,06, 29,84 ± 9,71, 33,2 ± 12,11 e 33,13 ± 10,09 em olhos emetrópicos, míopes, hipermétropes, equivalente esférico ≥0 e equivalente esférico <0 respectivamente. Foram encontradas diferenças significativas em todas as variáveis entre olhos emetrópicos e com hipermetropia corrigida, equivalente esférico ≥ 0 e equivalente esférico <0 (p<0,05).
Conclusão: Em condições com lentes corrigidas (com armações de prova), os olhos emetrópicos e com miopia simples apresentaram qualidade óptica significativamente melhor em comparação com os olhos hipermétropes e astigmáticos. O significado clínico destes resultados deve ser estudado posteriormente.
Keywords: Erro de refração; Emetropia; Dispositivo óptico; Técnica de diagnóstico oftalmológico/instrumentação; Refração ocular; Acuidade visual
Abstract
Objetivo: Investigar picos de pressão intraocular em pacientes fácicos e pseudofácicos com glaucoma primário de ângulo aberto no teste de sobrecarga hídrica.
Método: Quarenta pacientes com glaucoma primário de ângulo aberto foram avaliados; vinte eram fácicos e vinte eram pseudofácicos. Um olho (selecionado aleatoriamente) foi incluído no estudo, todos os pacientes foram submetidos às curvas da pressão intraocular imediatamente após o teste de sobrecarga hídrica.
Resultados: Observou-se uma diferença estatisticamente significante na média dos picos nas curvas da pressão intraocular para os pacientes fácicos e pseudofácicos (p=0,045). Houve diferença estatisticamente significante nos picos da pressão intraocular no teste de sobrecarga hídrica entre os grupos, sendo observados valores mais altos nos pacientes fácicos (p=0,004).
Conclusão: Os picos da pressão intraocular no teste de sobrecarga hídrica foram maiores no grupo fácico que no grupo pseudofácico.
Keywords: Glaucoma de ângulo aberto; Técnicas de diagnóstico oftalmológico; Água potável; Pressão intraocular
Abstract
Objetivo: O objetivo deste estudo é comparar as medições de diâmetro corneano de dois dispositivos normalmente utilizados na prática clínica (IOL Master 500 e Atlas topógrafo corneal) para ver se são permutáveis. O fornecimento de informações sobre a permutabilidade de instrumentos poderia eliminar vários testes desnecessários e, consequentemente, reduzir a carga econômica para o paciente e para a sociedade.
Métodos: Nesta série de casos prospectivos e comparativos, a distância do diâmetro corneano foi medida por examinadores independentes utilizando o Topógrafo Atlas (Carl Zeiss Meditec) e o IOL Master 500 (Carl Zeiss Meditec), em um olho de 184 pacientes. A análise estatística foi realizada utilizando o teste t pareado, a correlação Pearson e a análise Bland-Altman para comparar os métodos de medição.
Resultados: As medições médias da distância do diâmetro corneano com o topógrafo Atlas e o IOL Master 500 foram de 12,20 ± 0,44 mm e 12,12 ± 0,41 mm, respectivamente (p<0,001). A diferença média de WTW entre os dois dispositivos foi de 0,07 mm (intervalo de confiança de 95% da diferença média: 0,04 - 0,11 mm). O coeficiente de correlação Pearson entre os dois dispositivos foi de 0,85, p<0,0001. Os limites de concordância de 95% entre os dois dispositivos foram de -0,38 mm a 0,53 mm.
Conclusões: O Atlas topographer e o IOL Master 500 podem ser utilizados permutavelmente em relação à medição do diâmetro corneano, uma vez que a gama de diferenças encontradas é pouco susceptível de afetar a prática clínica e a tomada de decisões.
Keywords: Topografia da córnea; Comprimento axial do olho; Técnicas de diagnóstico oftalmológico; Procedimentos cirúrgicos oftalmológicos.
Abstract
PURPOSE: Although the orthokeratology effects on corneal biomechanics have been proven with clinical trials, reports of stiffness parameter change are scarce. This study investigated the short-term orthokeratology effects in pediatric myopia and compared stiffness parameter changes to those published in recent clinical investigations. This prospective study aimed to investigate corneal biomechanics changes induced by short-term overnight orthokeratology treatment, focusing on stiffness parameter at A1 and stress-strain index
METHODS: Twenty-six children aged 8 to 18 were included in this study using orthokeratology lenses for two different durations: 1 day and 1 week. Corneal biomechanics were assessed using corneal visualization (Corvis) Scheimpflug technology. Measurements were taken at baseline and after each wearing session. Changes in corneal stiffness parameters and corneal curvature were analyzed.
RESULTS: All parameters changed significantly after 1 week of lens wear (p<0.05), except for velocity of corneal apex at the first and second applanation times highest concavity time, radius, stiffness parameter at A1 and stress-strain index. After 1 day, central corneal thickness, first applanation time, second applanation time, deformation amplitude ratio (2 mm), and Corvis biomechanical index (CBI) remained stable (p>0.05). After 1 week, central corneal thickness and first applanation time decreased, whereas second applanation time, deformation amplitude ratio, and Corvis Biomechanical Index significantly increased. With intraocular pressure and central corneal thickness as control variables, no significant correlation was found between stress-strain index and curvature changes (p>0.05). With age as the control variable, no significant correlation was found between stress-strain index and curvature changes (p>0.05).
CONCLUSIONS: Short-term orthokeratology treatment induced notable changes in several corneal biomechanical parameters. Stiffness parameter at A1 and stress-strain index are unaffected by increasing lens wear duration and do not influence the orthokeratology effect.
Keywords: Orthokeratologic procedures; Epithelium, corneal; Corneal topography; Myopia/therapy; Diagnostic techniques, ophthalmological; Biomechanical phenomena; Refraction, ocular; Visual acuity; Humans; Children; Adolescent
Abstract
Objetivos: Procuramos avaliar o uso da pupilometria estática e dinâmica quantitativa automatizada na triagem de pacientes com diabetes mellitus tipo 2 e em diferentes estágios de retinopatia diabética.
Métodos: Cento e cinquenta e cinco pacientes com diabetes mellitus tipo 2 (grupo com diabetes mellitus) foram incluídos neste estudo e outros 145 controles saudáveis pareados por idade e sexo para server como grupo controle. O grupo com diabetes mellitus foi dividido em três subgrupos: diabetes mellitus sem retinopatia diabética (retinopatia não diabética), retinopatia diabética não proliferativa e retinopatia diabética proliferativa. A pupilometria estática e dinâmica foi realizada utilizando uma camera rotative Scheimpflug com um sistema baseado em topografia.
Resultados: Em termos de diâmetro da pupila, tanto na pupilometria estática quanto na dinâmica (p<0,05), foram observadas diferenças estatisticamente significantes entre os grupos diabetes mellitus e controle e também entre os subgrupos retinopatia não diabética, retinopatia diabética não proliferativa e retinopatia diabética proliferativa. Mas foi observado que os grupos de retinopatia não diabética e retinopatia diabética não proliferativa mostraram semelhanças nos achados derivados da pupilometria estática em condições mesópicas e fotópicas. Os dois grupos também pareciam semelhantes em todos os pontos durante a pupilometria dinâmica (p>0,05). No entanto, pode-se concluir que o grupo de retinopatia diabética proliferative foi sugnificativamente diferente do restante dos subgrupos, retinopatia não diabética e retinopatia diabética não proliferativa, em termos de todas as medidas de pupilometris estática (p<0,05). A velocidade média de dilatação também foi significativamente diferente entre os grupos diabetes mellitus e controle, e entre os subgrupos diabetes mellitus (p<0,001). Enquanto correlações significativas fracas a moderadas foram encontradas entre todos os diâmetros da pupila na pupilometria estática e dinâmica com a duração do diabetes mellitus (p<0,05 para todos), os valores de HbA1c não mostraram correlações estatisticamente significantes com nenhum dos diâmetros da pupila estática e dinâmica investigados (p>0,05 para todos).
Conclusão: Este estudo revelou que as medidas derivadas da pupilometria automatizada estão alteradas em pacientes com diabetes mellitus tipo 2. A presença de retinopatia diabética não proliferativa não afeta negativamente os achados pupilométricos, mas com a retinopatia diabética proliferative, alterações significativas foram observadas. Estes resultados sugerem que o uso da pupilometria quantitativa automatizada pode ser útil na verificação gravidade da retinopatia diabética.
Keywords: Retinopatia diabética; Diabetes Mellitus; Técnicas de diagnóstico oftalmológico; Pupila; Reflexo pupilar
Abstract
PURPOSE: This cross-sectional study compared best-corrected visual acuity obtained using Cloudscaper symbols, a novel optotype developed according to ETDRS specifications for children's virtual screening, with that obtained using LEA symbols.
METHODS: A total of 560 children aged 3-16 yr underwent visual acuity test with both Cloudscaper symbols and LS. The test application was standardized using the EyeSpy algorithm. Additionally, 147 participants were tested with the standard Snellen E paper chart. Paired t tests were performed to assess the clinical significance of logMAR visual acuity differences.
RESULTS: The mean logMAR visual acuity with LEA symbols was 0.12 (standard deviation [SD]=0.18; range, -0.10 to 0.80), while with Cloudscaper symbols it was 0.18 (SD=0.19; range, -0.10 to 0.80). The mean difference between Cloudscaper symbols and LEA symbols was 0.099 logMAR (approximately 0.5 optotypes; SD=0.08; range, 0.0-0.14; p<0.0001). Cloudscaper symbols slightly underestimated visual acuity compared to LEA symbols. Visual acuity measured by both methods was highly correlated (Spearman's r=0.74, p<0.0001). The mean visual acuity difference between Cloudscaper symbols and the Snellen E chart was 0.0045 (p=0.805; 95% confidence interval [95% CI]), whereas the difference between LEA symbols and Snellen E was 0.0883 (p<0.001; 95% CI).
CONCLUSIONS: Cloudscaper symbols provide a reliable tool for visual screening in children. Although they slightly underestimate visual acuity compared to LEA symbols – a finding also reported when comparing ETDRS letters with LEA symbols – Cloudscaper symbols show strong agreement with Snellen E chart measurements. This suggests that Cloudscaper symbols allow precise visual acuity assessment comparable to the gold standard.
Keywords: Vision screening; Vision tests; Visual acuity; Mobile applications; Eye health; Child health; Diagnostic techniques, Ophthalmological; Child; Preschool child; Adolescent
Abstract
Objetivo: Avaliar as alterações da superfície ocular em pacientes com Rosácea, e comparar com grupo controle.
Métodos: Noventa e três indivíduos foram selecionados para este estudo transversal, observacional e não intervencionista, dividido em dois grupos: rosácea (n=40) e controles (n=53). Foram avaliados parâmetros objetivos da superfície ocular (hiperemia conjuntival, estabilidade e volume do filme lacrimal, disfunção da glândula meibomiana, doença do olho seco, coloração da superfície ocular) e comparado indivíduos saudáveis com pacientes com rosácea.
Resultados: 69,23% dos indivíduos com rosácea eram mulheres, com média de idade de 47,34 ± 12,62 anos. Em comparação com controles pareados, não foram evidenciadas diferenças estatisticamente significativas em relação à acuidade visual (p=0,987) e parâmetros do filme lacrimal (altura do menisco lacrimal (p=0,338), tempo de ruptura do filme lacrimal não invasivo (p=0,228), tempo invasivo de ruptura (p=0,471) e teste de Schirmer (p=0,244), bem como hiperemia conjuntival (p=0,106) e coloração com fluoresceína (p=0,489). Associação significativa foi encontrada na avaliação da meibografia (p=0,026), integridade da camada mucosa (p=0,015) e sintomas de superfície ocular (p<0,0001). Pacientes com rosácea também apresentaram alterações importantes na borda palpebral: expressibilidade glandular (p<0,001), padrão de secreção glandular (p<0,001) e telangiectasia (p<0,001).
Conclusão: A disfunção da glândula de Meibômio está frequentemente associada a condições dermatológicas e é caracterizada por achados morfológicos na meibografia, bem como comprometimento da secreção lipídica que leva ao olho seco evaporativo e alterações da superfície ocular e inflamação.
Keywords: Rosácea/complicações; Disfunção da glândula tarsal; Túnica conjuntiva; Síndromes do olho seco; Técnicas de diagnóstico oftalmológico.
Abstract
PURPOSE: This pilot study evaluated the diagnostic accuracy of a deep learning model for detecting pterygium in anterior segment photographs taken using smartphones in the Brazilian Amazon. The model’s performance was benchmarked against assessments made by experienced ophthalmologists, considered the clinical gold standard.
METHODS: In this cross-sectional study, 38 participants (76 eyes) from Barcelos, Brazil, were enrolled. Trained nonmedical health workers captured high-resolution anterior segment images using smartphones. These images were analyzed using a deep learning model based on the MobileNet-V2 convolutional neural network. Diagnostic metrics–including sensitivity, specificity, accuracy, positive predictive value, negative predictive value, and area under the receiver operating characteristic curve–were calculated and compared with the ophthalmologists’ evaluations.
RESULTS: The deep learning model achieved a sensitivity of 91.43%, specificity of 90.24%, positive predictive value of 88.46%, negative predictive value of 92.79%, and an area under the curve of 0.91. Logistic regression revealed no statistically significant association between pterygium and demographic variables such as age or gender.
CONCLUSIONS: The deep learning model demonstrated high diagnostic performance in identifying pterygium in a remote Amazonian population. These preliminary findings support the potential use of artificial intelligence–based tools to facilitate early detection and screening in underserved regions, thereby enhancing access to ophthalmic care.
Keywords: Pterygium/diagnostic imaging; Smartphone; Diagnostic techniques, ophthalmological; Deep learning; Telemedicine; Artificial intelligence; Cross-sectional studies; Brazil/epidemiology
Abstract
PURPOSE: Access to cataract treatment and diagnostic tools continues to be hindered by financial and logistical barriers. Thus, photography-based cataract analysis via portable devices offers a promising solution for the detection of cataracts in remote regions. In this study, the accuracy of a portable device that is based on the Lens Opacities Classification III System for diagnosing cataracts was analyzed.
METHODS: Photographs of the anterior segment of the eye were taken in a low-light environment, and the pupillary region markings were automatically delineated using infrared photography. The captured images were automatically analyzed using a convolutional neural network. The study group included patients with cataracts, and the control group included patients without cataracts.
RESULTS:A total of 270 eyes were analyzed, which included 143 eyes with cataracts and 127 control eyes. A total of 599 photos were analyzed. The isolated nuclear cataract was the most frequently detected subtype (37.5%), followed by a nuclear cataract associated with a cortical cataract (30.3%). The device's accuracy was 88.5% (Confidence intervals (CI), 83.19%–94.69%), specificity was 84.62% (CI 71.79%–97.30%), positive predictive value was 91.78% (CI 74.36%–97.30%), and negative predictive value was 82.50% (CI 74.36%–97.30%).
CONCLUSION: The portable device is a simplified user-friendly cataract screening technique that can interpret results in remote regions. This innovation could mitigate the occurrence of cataract-induced blindness and prevent premature surgical interventions in early-stage cataracts.
Keywords: Cataract/diagnosis; Diagnostic techniques ophthalmological/instrumentation; Optical devices; Equipment and supplies; Eye-tracking technology
Abstract
Objetivo: Comparar os parâmetros de câmara anterior obtidos através da tomografia de coerência óptica de segmento anterior antes e após a iridectomia periférica a laser.
Métodos: Quatorze pacientes com fechamento angular primário e seis com glaucoma primário de ângulo fechado foram prospectivamente avaliados neste estudo. Gonioscopia e tomografia de coerência óptica de segmento anterior com DRI OCT Triton®foram realizadas antes e após a iridectomia periférica a laser. Os seguintes parâmetros de tomografia de coerência óptica de segmento anterior, baseados na localização do esporão escleral, foram avaliados: ângulo de abertura angular a 250 µm, 500 µm e 750 µm, área do espaço entre a íris e o trabeculado a 500 µm, ângulo entre a íris e o trabeculado, extensão do contato entre a íris e o trabeculado e curvatura da íris.
Resultados: A tomografia de coerência óptica de segmento anterior identificou 61% dos indivíduos com dois ou mais quadrantes fechados. A gonioscopia identificou mais quadrantes com ângulo fechado do que tomografia de coerência óptica de segmento anterior antes da iridectomia periférica a laser. Quanto aos parâmetros angulares, apenas ângulo de abertura angular a 250 µm no quadrante nasal não aumentou significativamente após a iridectomia
periférica a laser. A curvatura da íris e a extensão do contato entre a íris e o trabeculado apresentaram redução significativa induzida pelo procedimento a laser. Mesmo nos olhos em que a gonioscopia não identificou aumento da amplitude angular após iridectomia periférica a laser (n=7), ângulo de abertura angular a 750 µm aumentou (nasal: 0,15 ± 0,10 mm para 0,27
± 0,16 mm, p=0,01; temporal: 0,14 ± 0,11 mm para 0,25 ± 0,12 mm, p=0,001), e ICURVE diminuiu (nasal: 0,25 ±
0,04 mm vs. 0,11 ± 0,07 mm, p=0,02; temporal: 0,25 ± 0,07 mm vs. 0,14 ± 0,08 mm, p=0,007).
Conclusão: As alterações na câmara anterior induzidas pelo iridectomia periférica a laser puderam ser avaliadas quantitativamente e documentadas pelo DRI OCT Triton®.
Keywords: Gonioscopia; Tomografia de coerência óptica; Segmento anterior do olho; Glaucoma de ângulo fechado; Iridectomia; Terapia a laser; Lasers
Abstract
OJETIVOS: O olho seco é uma doença multifatorial, muito comum na prática clínica oftalmológica. A utilização de questionários validados de sintomas de olho seco permite rastrear de maneira mais objetiva essa doença na população geral, avaliar a prevalência dos sintomas e frequência de diagnóstico, permitindo o tratamento precoce e adequado dessa condição. O 5-Item Dry Eye Questionnaire (DEQ-5) é um questionário em inglês que avalia a frequência e a intensidade do desconforto e ressecamento ocular e a frequência do lacrimejamento, já validado no inglês e espanhol, porém não no português até o presente momento. O objetivo deste estudo foi traduzir e validar o questionário DEQ-5 para a língua portuguesa.
MÉTODOS: Foi utilizado o questionário DEQ-5, composto por 5 perguntas simples e diretas - 2 relacionadas ao desconforto ocular, 2 ao ressecamento ocular e 1 ao lacrimejamento. Foi realizada a tradução inicial da versão em inglês para o português por dois tradutores de língua materna portuguesa, seguido de uma avaliação e compilação de uma versão única por um comitê interdisciplinar das versões traduzidas. Em seguida, tal versão foi traduzida de volta para o inglês por 2 indivíduos que possuíam o inglês como primeira língua, seguido de avaliação e comparação com a versão original em língua inglesa pelo mesmo comitê interdisciplinar. Após, a versão final do questionário foi aplicada em 31 voluntários em dois momentos diferentes.
RESULTADOS: A confiabilidade interobservador das 5 perguntas variou de 0,584-0,813 e a correlação de Pearson de 0.755-0.935, sendo o p-valor <0,0001 em todas elas. A consistência interna foi α=0,887. Todas as perguntas apresentaram concordância de moderada a alta.
CONCLUSÕES: A análise estatística dos dados coletados encontrou ótimos índices de concordância - moderada a alta para todas as questões analisadas -, permitindo o uso do DEQ-5 na língua portuguesa em pesquisas e também como forma de triagem para doença de olho seco e acompanhamento dos sintomas.
Keywords: Síndromes do olho seco; Técnicas de diagnóstico oftalmológico; Inquéritos e questionários; Traduções
Abstract
PURPOSE: To quantitatively assess changes in central corneal sensitivity after phacoemulsification and to characterize recovery patterns up to 90 days using standardized esthesiometry.
METHODS: This prospective observational study included 44 patients (88 eyes) undergoing uncomplicated phacoemulsification with intraocular lens implantation. Central corneal sensitivity was measured using a Cochet-Bonnet® esthesiometer preoperatively and at 30 and 90 days postoperatively. Repeated-measures data were analyzed using Friedman and Wilcoxon signed-rank tests (p<0.05). Inter-eye differences were assessed with a paired Wilcoxon test. Individual changes from baseline (Δ30, Δ90) were calculated, and 90-day recovery was categorized according to thresholds aligned with the 5-mm device resolution. Spearman correlation was used to explore associations between age and Δ90.
RESULTS: Corneal sensitivity decreased after surgery. In right eyes, mean sensitivity declined from 41.14 ± 7.77 mm at baseline to 36.82 ± 9.03 mm at 30 days and partially recovered to 38.64 ± 7.73 mm at 90 days. In left eyes, sensitivity decreased from 44.11 ± 6.29 mm to 37.39 ± 9.05 mm at 30 days and recovered to 41.82 ± 7.63 mm at 90 days. Left eyes showed higher sensitivity than right eyes at baseline (p=0.023) and at 90 days (p=0.018). At 90 days, complete or near-complete recovery (within ± 5 mm of baseline) occurred in 73.2% of right eyes and 78.0% of left eyes, while improvement above baseline (≥ +5 mm) occurred in 7.3% and 4.9%, respectively. Age showed weak, nonsignificant correlations with Δ90 (p=−0.14 to −0.19; p>0.2).
CONCLUSION: Phacoemulsification with a 2.75-mm clear corneal incision leads to a temporary reduction in central corneal sensitivity, with partial recovery by 90 days. Recovery patterns vary among individuals, highlighting the value of postoperative sensitivity monitoring to identify atypical trajectories and guide ocular surface care during visual rehabilitation.
Keywords: Phacoemulsification; Cornea/innervation; Ophthalmic nerve/physiology; Optometry/instrumentation; Diagnostic techniques, ophthalmological; Neural regeneration; Visual rehabilitation.
Abstract
Objetivo: A possível variabilidade nos resultados de testes diagnósticos é uma característica estatística dos pacientes com síndrome do olho seco. O médico deve considerar as variações do filme lacrimal ao longo do tempo, pois o momento em que o filme lacrimal é medido pode ser crítico para o diagnóstico adequado. O objetivo deste estudo foi analisar a variação semanal da osmolaridade do filme lacrimal em participantes saudáveis e em outros com síndrome do olho seco.
Métodos: Com base nos critérios da metodologia de diagnóstico do relatório da Dry Eye Workshop II (DEWSII), foi aplicada uma bateria de testes (questionário do índice de doença da superfície ocular [OSDI], tempo de ruptura do filme lacrimal e coloração da córnea) para descartar a presença de síndrome do olho seco. Um total de 40 voluntários qualificados foi recrutado e distribuído em dois grupos de 20 participantes saudáveis e 20 participantes com síndrome do olho seco. A variação da osmolaridade entre semanas foi medida com um osmômetro TearLab em duas sessões com uma semana de intervalo nos dois grupos. As diferenças entre os resultados foram então calculadas.
Resultados: Não foram encontradas diferenças significativas na osmolaridade entre as medidas obtidas nas duas sessões, nem no grupo de participantes saudáveis (teste de t pareado; p=0,085), nem no de participantes com síndrome do olho seco (teste de t pareado; p=0,093). Não foi detectada nenhuma correlação significativa entre as médias e diferenças entre as duas sessões entre participantes saudáveis (correlação de Pearson: r=0,020, p=0,935) e aqueles com síndrome do olho seco (correlação Pearson: r=-0,022, p=0,928). Foi encontrada uma diferença significativa nos valores de osmolaridade entre os dois grupos na primeira sessão (teste de t não pareado; p=0,001), mas nenhuma diferença foi encontrada na segunda sessão (teste de t não pareado; p=0,292).
Conclusões: O presente estudo não encontrou variação entre semanas consecutivas na osmolaridade do filme lacrimal em participantes saudáveis e com síndrome do olho seco, classificados com base nos critérios do DEWSII.
Keywords: Concentração osmolar; Lágrimas; Síndromes do olho seco; Técnicas de diagnóstico oftalmológico
Abstract
Objetivos: Este estudo teve como objetivo examinar a superfície ocular de crianças com transtorno de déficit de atenção com hiperatividade e identificar os efeitos adversos do metilfenidato relacionados à síndrome do olho seco.
Métodos: Este estudo transversal incluiu crianças com transtorno de déficit de atenção e hiperatividade e crianças saudáveis (todas entre 5-18 anos de idade). Elas foram randomizadas no Grupo A (sem tratamento com metilfenidato), Grupo B (com tratamento com metilfenidato) e Grupo C (crianças saudáveis). Foram avaliados o tempo de ruptura do filme lacrimal, questionário sobre Índice de Doenças de Superfície Ocular (IDSO), altura do menisco lacrimal, área do menisco lacrimal e os resultados do teste de Schirmer. Além disso, a gravidade dos sintomas no transtorno de déficit de atenção com hiperatividade foi avaliada usando a Turgay DSM-IV-based Child and Adolescent Behavioral Disorders Screening and Rating Scale com base na escala de Conners Parent Rating Scale-48.
Resultados: Os Grupos A, B e C consistiram de 34, 40 e 60 indivíduos (n=34, 40 e 60 olhos; idade=11,44 ± 2,79, 11,70 ± 2,83 e 11,96 ± 3,63 anos, idade média=12, 123 e 11,5 anos), respectivamente. O tempo de ruptura do filme lacrimal, o Índice de Doença da Superfície Ocular, as altura do menisco lacrimal, a área do menisco lacrimal e o teste de Schirmer não foram significativamente diferentes entre os Grupo A e C (p=0,964, 0,336, 0,445, 0,439 e 0,759, respectivamente). Entretanto, o Grupo B mostrou uma redução significativa no tempo de ruptura do filme lacrimal (10,50 ± 3,39 vs 12,52 ± 2,46 seg; p=0,005), altura do menisco lacrimal (307,40 ± 5,53 vs 310,82 ± 7,30 µm; p= 0,025), área do menisco lacrimal (0,024 ± 0,0037 vs 0,026 ± 0,0046 mm2; p=0,010) e teste de Schirmer (12,75 ± 3,96 vs 15,41 ± 3,75 mm; p=0,004), resultados com0arados com o Grupo A.
Conclusão: Em comparação com crianças saudáveis, crianças com transtorno de déficit
de atenção com hiperatividade apresentaram parâmetros de superfície ocular sugestivos de olho seco, apesar do uso de metilfenidato. Assim, elas requerem um acompanhamento oftalmológico próximo para evitar complicações oculares de olho seco que ameaçam a visão.
Keywords: Transtorno do deficit de atenção com hiperatividade; Metilfenidato/efeitos adversos; Segmento anterior do olho; Tomografia de coerência óptica; Síndrome do olho seco
Abstract
PURPOSE: To evaluate the clinical results of cryopreserved amniotic membrane transplantation as a treatment option for refractory neurotrophic corneal ulcers.
METHODS: This prospective study included 11 eyes of 11 patients who underwent amniotic membrane transplantation for the treatment of refractory neurotrophic corneal ulcers at Hospital de Clínicas da Universidade Federal do Paraná, in the city of Curitiba, from May 2015 to July 2021. Patients underwent different surgical techniques in which the amniotic membrane was applied with the epithelium facing upward to promote corneal re-epithelialization.
RESULTS: The median age of the patients was 60 years (range, 34-82 years), and 64% were men. The predominant etiology of corneal ulcers was herpes zoster (45% of cases). Approximately one-third of the patients (27%) were chronically using hypotensive eye drops, and more than half (54%) had previously undergone penetrating corneal transplantation. At the time of amniotic membrane transplantation, 18% of the eyes had corneal melting, 9% had corneal perforation, and the others had corneal ulceration without other associated complications (73%). The time between clinical diagnosis and surgical treatment ranged from 9 days to 2 years. The corrected visual acuity was worse than 20/400 in 90% of the patients preoperatively, with improvement in 36% after 3 months of the procedure, worsening in 18% and remaining stable in 36%. Of the patients, 81% complained of preoperative pain, and 66% of them reported total symptom relief after the surgical procedure. In one month, 54.6% of the patients presented a closure of epithelial defect, and half of the total group evolved with corneal thinning. The failure rate was 45.5% of the cases.
CONCLUSION: Cryopreserved amniotic membrane transplantation can be considered a good alternative for treating refractory neurotrophic corneal ulcers, as it resulted in significant improvement in pain (66%) and complete epithelial closure (60%) in many patients at 1 month postoperatively. Notably, the high failure rate highlights the need for further studies to identify patient- and ulcer-related factors that may influence the outcomes of this procedure.
Keywords: Amnion/transplantation; Corneal ulcer; Anterior eye segment; Keratitis
ABO is licensed under a Creative Commons Attribution-NonComercial 4.0 Internacional.
About
Issues
Editorial Board
Submission
Official publication of Conselho Brasileiro de Oftalmologia
Rua Casa do Ator, 1.117 - 2º andar - CEP: 04546-004
São Paulo - SP, Brazil
Phone: +55 11 3266-4000