Showing of 1 until 15 from 86 result(s)
Search for: Perimetry; Perimetry; Visual fields; Age groups; Sensory threshold; Aging
Abstract
Objetivo: Analisar os resultados de um estudo comparativo entre as estratégias dinâmica e normal utilizando o perí-metro Octopus 1-2-3. Métodos: Utilizando o Octopus 1-2-3 nas estratégias dinâmica e normal foi realizada a perimetria automatizada em 24 pacientes glaucomatosos (8 homens e 16 mulheres) com uma média de intervalo entre os 2 exames de 6 meses. Todos pacientes já haviam sido previamente submetidos a pelo menos um exame de perimetria automatizada no Octopus 1-2-3. Os dados comparados, para ambos os olhos, foram: a idade do paciente, número de estímulos, sensibilidade média (MS), defeito médio (MD), perda localizada (LV), flutuação em curto prazo (SF) e o fator de confiabilidade (RF). Na análise estatística, utilizando o teste t pareado, somente os campos visuais com RF menor que 10 foram incluídos. O nível de significância foi igual a 5% (p < 0,05). Resultados: Não houve diferença estatisticamente significativa entre as duas estratégias em relação à idade, LV, SF e RF. Entretanto, houve diferença estatisticamente significativa na duração do teste, número de estímulos, MS e MD. A estratégia dinâmica mostrou uma sensibilidade difusa maior e um menor defeito médio quando comparada à estratégia normal. Conclusões: Nossos resultados indicam que os valores dos limiares medidos pela estratégia dinâmica estão em concordância com os valores obtidos utilizando a estratégia normal nos pacientes portadores ou suspeitos de glaucoma, cujos campos visuais estão normais ou limítrofes. Estes resultados também confirmam a redução na duração do exame. Também sugerem que, quando compararmos campos visuais realizados com a estratégia dinâmica com aqueles realizados com a estratégia normal, é necessária cautela em relação aos valores do MS e MD.
Keywords: Perimetria automatizada; Glaucoma; Octopus 1-2-3
Abstract
OBJETIVO: Avaliar comparativamente o limiar de sensibilidade macular da microperimetria e a estabilidade de fixação entre o primeiro (direito) e o segundo (esquerdo) olhos testados de indivíduos normais.
MÉTODOS: Trinta pacientes saudáveis foram divididos aleatoriamente em 2 grupos. Os participantes foram submetidos à microperimetria no “fast mode” e no “expert mode” no grupo I e II, respectivamente. Cada participante foi submetido a um único teste e o olho direito foi testado primeiro.
RESULTADOS: No grupo I, o limiar médio de sensibilidade macular (± DP) foi de 24,5 ± 2,3 dB e 25,7 ± 1,1 dB nos olhos direito e esquerdo, respectivamente (p=0,0415). No grupo II foi de 26,7 ± 4,5 dB e 27,3 ± 4,0 dB nos olhos direito e esquerdo, respectivamente (p=0,58). Não houve diferença estatisticamente significativa entre os olhos dos dois grupos (p=0,1512). Em relação à estabilidade de fixação (avaliada no grupo microperimetria no “expert mode”), a média das porcentagens dos pontos de fixação dentro do 1 grau central da mácula (P1) ± DP foi de 87,9 ± 11,5% no olho direito e de 93,8 ± 6,6% no olho esquerdo. O teste t pareado não mostrou diferença estatística entre os olhos (p=0,140). O valor médio de P2 ± DP foi de 95,5 ± 4,9% no olho direito e 98,5 ± 2,1% no olho esquerdo. Foi demonstrado um aumento na porcentagem de pontos de fixação no segundo olho testado quando comparado ao primeiro (teste t pareado= 2,364; p=0,034). Houve correlação negativa entre o limiar de sensibilidade macular do olho direito e a duração do exame nos dois grupos (microperimetria no “expert mode”: r=-0,717; p=0,0026; microperimetria no “fast mode”: r=-0,843; p <0,0001).
CONCLUSÃO: O limiar médio de sensibilidade macular foi maior no segundo olho testado no grupo microperimetria no “fast mode” e foi semelhante nos dois olhos no “expert mode”. Nossos dados sugerem que a compreensão do exame pelo indivíduo pode impactar nos resultados da microperimetria.
Keywords: Macula lutea; Fixação ocular; Viés; Campos visuais; Acuidade visual
Abstract
Objetivo: investigar os efeitos vasculares da fotobiomodulação com diodo emissor de luz utilizando membrana embrionária corioalantóide de ovos de galinhas em grupos com diferentes tempos de exposição e detectar as alterações morfológicas por meio de métricas quantitativas promovidas pela luz na arquitetura da rede vascular.
Métodos: Um aparelho de fototerapia com diodo emissor de luz no comprimento de onda de 670 nm foi usado como fonte de fotobiomodulação. A luz vermelha foi aplicada a uma distância de 2,5 cm da superfície da membrana embrionária corioalantóide em 2, 4 ou 8 sessões de 90 s a arquitetura da rede vascular foi analisada por meio do software AngioTool (National Cancer Institute, USA). Usamos um grupo controle negativo tratado com 50 µL de solução salina tamponada com fosfato (PBS) pH 7,4 e um grupo controle positivo (Beva) tratado com 50 µL de solução de bevacizumabe (Avastin, Produtos Roche Químicos e Farmacêuticos S.A., Brasil).
Resultados: Uma diminuição no comprimento total do vaso foi detectada para o grupo Beva (24,96 ± 12,85%), e para todos os grupos que receberam terapia de luz vermelha de 670 nm, 34,66 ± 8,66% (2x), 42,42 ± 5,26% (4x) e 38,48 ± 6,96% (8x) em comparação ao grupo controle. A incidência de 5,4 J/cm2 em 4 sessões (4x) mostrou vasos mais regulares. A redução foi mais intensa nos grupos que receberam maior incidência de luz vermelha de 670 nm (4x e 8x).
Conclusão: A fotobiomodulação contribui para a redução da vascularização nos vasos da membrana embrionária corioalantóide de ovos de galinhas e mudanças na arquitetura da rede. Os achados deste experimento abrem a possibilidade de considerar um estudo clínico usando esta terapia em pacientes com doenças retinais com componentes neovasculares, especialmente degeneração macular relacionada à idade.
Keywords: Fotobiomodulação; Membrana corioalantoica; Terapia com luz vermelha; Angiogênese; Degeneração macular relacionada à idade; Vasos retinais
Abstract
OBJETIVO: A atividade da paraoxonase1 está associada à degeneração macular relacionada à idade. Dois polimorfismos (L55M e Q192R) mostraram aumentar a atividade da paraoxonase1 e foram implicados no desenvolvimento da degeneração macular relacionada à idade. Os estudos que examinaram esses polimorfismos apresentaram resultados conflitantes: nenhum efeito, risco aumentado ou diminuído. Assim, esta meta-análise foi realizada para determinar o efeito desses polimorfismos na degeneração macular relacionada à idade.
MÉTODOS: Foi feita uma busca nos bancos de dados PubMed, EBSCO, LILACS e SCOPUS, bem como nas bibliografias compiladas das publicações, buscando-se estudos caso-controle que tivessem analisado os polimorfismos da paraoxonase1 e a degeneração macular relacionada à idade. Os dados foram analisados com software Comprehensive Meta-Analysis, versão 2.2, e NCSS Statistical, versão 2020. As distribuições de genótipos foram extraídas e, dependendo do nível de heterogeneidade, modelos de efeitos fixos ou aleatórios foram utilizados para calcular razões de probabilidade (RPs) combinadas, com intervalos de confiança de 95% (IC 95%) para os modelos genéticos heterozigoto, homozigoto, dominante, recessivo e alélico.
RESULTADOS: Em geral, nenhum dos modelos genéticos demonstrou associação significativa para o polimorfismo L55M. Entretanto, em populações não asiáticas, foi determinada uma associação significativa para os modelos genéticos heterozigoto e dominante (RPfaixa=1,24-1,27, p<0,05). Para a população asiática, os modelos heterozigoto, dominante e alélico mostraram um fator benéfico ou protetor (RPfaixa=0,29-0,35, p<0,05). Para o polimorfismo Q192R, nenhum dos modelos genéticos demonstrou qualquer associação significativa. Porém, quando a coorte foi agrupada por etnia, determinou-se uma associação significativa na população asiática para os modelos genéticos recessivo e alélico (RPfaixa=1,63-2,08, p<0,05). Contudo, nenhuma associação foi observada para a população não asiática. Não houve risco identificável quando a coorte foi estratificada em exsudativa e não exsudativa.
CONCLUSÕES: Determinamos que o polimorfismo L55M da paraoxonase1 de fato aumenta o risco de desenvolvimento de degeneração macular relacionada à idade em populações não asiáticas, enquanto que em populações asiáticas, esse polimorfismo tem um efeito protetor. Porém, para o polimorfismo Q192R da paraoxonase1, apenas a população asiática demonstrou risco de desenvolver degeneração macular relacionada à idade.
Keywords: Grupos étnicos; Degeneração macular; Polimorfismo genético; Paraoxonase1; Arildialquilfosfatase
Abstract
PURPOSE: This retrospective study evaluated the safety and efficacy of real-world antiangiogenic therapy for ocular conditions in the private healthcare sector in southern Brazil.
METHODS: Medical records from patients who underwent intravitreal anti-vascular endothelial growth factor injections over the past 12 years were reviewed retrospectively. Data collection included the primary diagnoses, drugs administered, injection techniques, adverse effects, and treatment efficacy. Efficacy was assessed by comparing pre- and posttreatment visual acuity and central subfield thickness in eyes with followup exceeding 2 years.
RESULTS: A total of 1,024 patients, 1,310 treated eyes, and 11,377 injections were analyzed. The injections included aflibercept (6,833), ranibizumab (3,692), bevacizumab (843), and brolucizumab (9), administered either bilaterally (3,696) or unilaterally (7,681). The most common diagnoses were diabetic macular edema, exudative age-related macular degeneration, retinal vein occlusion related macular edema, and proliferative diabetic retinopathy. No endophthalmitis cases were reported. Vitritis with transient visual acuity loss occurred in two cases following aflibercept injections. One retinal detachment case was successfully treated with vitrectomy. The median number of injections per patient was 6 (IQR [interquartile range], 3–13). Among 445 eyes from 328 patients with followup over 2 years (median, 4.05 years; IQR, 2.89–6.29), there was a significant improvement in best-corrected visual acuity from 0.3 to 0.4 (Snellen) (p<0.001) and a reduction in central subfield thickness from 361 to 267 microns (p<0.001). CST comparisons included patients with age-related macular degeneration, diabetic macular edema, and retinal vein occlusion related macular edema.
CONCLUSION: This real-world study, the largest of its kind in Brazil, confirms the safety and efficacy of antiangiogenic therapies in the southern Brazilian private healthcare system. The findings highlight a low incidence of severe adverse events and outcomes consistent with global studies, supporting the ongoing use of antiangiogenic agents as effective and well-tolerated treatments for various ocular conditions in developing countries.
Keywords: Antiangiogenic drugs; Macular edema; Age-related macular degeneration; Retinal vein occlusion; Patient safety
Abstract
Objetivos: A microperimetria tem sido usada há vários anos como uma forma de teste de função visual em pacientes com doenças da retina. Os valores normais de microperimetria obtidos com MP-3 ainda não foram totalmente publicados e os valores basais para sensibilidade macular topográfica e correlações com idade e sexo são necessários para estabelecer graus de comprometimento. O objetivo do trabalho é determinar valores para limiares de sensibilidade à luz e estabilidade de fixação usando o MP-3 em indivíduos normais.
Métodos: Trinta e sete voluntários saudáveis (idade: 28-68 anos), submetidos à microperimetria de limiar total usando uma estratégia de escada 4-2 (rápida) com o tamanho de estímulo padrão Goldmann III e 68 pontos de teste posicionados de forma idêntica aos do Humphrey Field Analyzer 10-2 grade de teste. A estabilidade da fixação foi registrada simultaneamente durante o teste de microperimetria. A relação entre a sensibilidade global e a idade foi calculada por meio de análise de regressão linear.
Resultados: A microperimetria foi realizada em 37 indivíduos (74 olhos). A sensibilidade média global foi de 29,01 ± 1,44 dB, intervalo: 26-31 dB. A mediana da sensibilidade central a 2° medida pelo MP-3 foi de 28,5 ± 1,77 dB (ER) e 28,75 ± 1,98 dB (OE). Os valores médios totais de estabilidade da fixação em 2° e 4° foram 80% e 96%, respectivamente. A análise de regressão linear também revelou um declínio de sensibilidade global relacionado à idade por ano de -0,051 dB ± 0,018 (ER) e -0,078 dB ± 0,021 (LE).
Conclusões: A microperimetria realizada com o MP-3 permite um exame automático, preciso e específico da topografia dos limiares de sensibilidade da retina. Os resultados deste estudo fornecem um banco de dados normal e de idade correspondente da microperimetria MP-3.
Keywords: Campos visual; Testes de campo visual; Retina; Microperímetro; Idade.
Abstract
PURPOSE: This study aimed to evaluate the relationship between the objective severity of dry eye disease subjective symptoms, and corneal sensitivity.
METHODS: The study included 62 eyes from 31 healthy volunteers and 150 eyes from 75 patients diagnosed with dry eye disease . Participants underwent the Schirmer I test, tear break-up time assessment, and corneal staining evaluation using the Oxford Scale. Subjective symptoms were assessed through the Ocular Surface Disease Index questionnaire and a modified Ocular Surface Pain Score questionnaire. Corneal sensitivity was measured in five corneal regions using a Cochet-Bonnet esthesiometer. Dry eye disease severity was graded from 1 to 5 based on the Oxford Scale. Comparative analyses were performed.
RESULTS: Schirmer I and tear break-up time values were significantly lower in the DED group, while Ocular Surface Disease Index and Ocular Surface Pain Score were significantly higher (p<0.001 for all). Corneal sensitivity in all quadrants was significantly lower in DED patients (p<0.001 for all). A strong correlation was observed between the Ocular Surface Pain Score and the Ocular Surface Disease Index (r=0.983, p<0.001). Central corneal sensitivity exhibited a moderate positive correlation with Schirmer I and tear break-up time (p<0.001, r=0.583 and 0.657, respectively) and a moderate negative correlation with Ocular Surface Disease Index and Ocular Surface Pain Score (p<0.001, r=0.625 and −0.631, respectively). Disease severity progression was associated with increased Ocular Surface Disease Index and Ocular Surface Pain Score, but no statistically significant difference was found between Grades 3 and 5. Similarly, corneal sensitivity decreased with advancing disease severity, yet no significant difference was observed between Grades 4 and 5.
CONCLUSION: Corneal sensitivity decreases in dry eye disease and is negatively correlated with disease severity. Subjective symptoms increase with disease progression and show a positive correlation with severity. The absence of significant differences between the advanced stages suggests that neuropathic mechanisms and subbasal nerve plexus deterioration play a role in chronic and late-stage dry eye disease.
Keywords: dry eye disease; signs and symptoms; cornea; neuralgia; Cochet-Bonnet esthesiometer; sensory thresholds; surveys and questionnaires
Abstract
PURPOSE: Standard automated perimetry has been the standard method for measuring visual field changes for several years. It can measure an individual’s ability to detect a light stimulus from a uniformly illuminated background. In the management of glaucoma, the primary objective of perimetry is the identification and quantification of visual field abnormalities. It also serves as a longitudinal evaluation for the detection of disease progression. The development of artificial intelligence-based models capable of interpreting tests could combine technological development with improved access to healthcare.
METHODS: In this observational, cross-sectional, descriptive study, we used an artificial intelligence-based model [Inception V3] to interpret gray-scale crops from standard automated perimetry that were performed in an ophthalmology clinic in the Brazilian Amazon rainforest between January 2018 and December 2022.
RESULTS: The study included 1,519 standard automated perimetry test results that were performed using Humphrey HFA-II-i-750 (Zeiss Meditech). The Subsequently, 70%, 10%, and 20% of the dataset were used for training, validation, and testing, respectively. The model achieved 80% (68.23%–88.9%) sensitivity and 94.64% (88.8%–98%) specificity for detecting altered perimetry results. Furthermore, the area under the receiver operating characteristic curve was 0.93.
CONCLUSIONS: The integration of artificial intelligence in the diagnosis, screening, and monitoring of pathologies represents a paradigm shift in ophthalmology, enabling significant improvements in safety, efficiency, availability, and accessibility of treatment.
Keywords: Glaucoma; Disease progression; Perimetry; Visual Fields; Visual field tests; Artificial intelligence; Neural networks, computers; Machine learning
Abstract
OBJETIVO: A deficiência visual e a cegueira causadas pela catarata são um grande problema de saúde pública. Há vários fatores associados a um risco maior de catarata relacionada à idade na população mundial, tais como idade, tabagismo, consumo de álcool e radiação ultravioleta. Esta meta-análise foi realizada para avaliar a associação entre o índice de massa corporal e a catarata relacionada à idade.
MÉTODOS: Foi revisada a literatura sobre catarata relacionada a peso e idade publicada de janeiro de 2011 a julho de 2020, através de buscas nos bancos de dados PubMed, Medline e Web of Science. Na meta-análise, foram utilizados modelos de efeito aleatórios e de efeitos fixos e os resultados foram apresentados como razões de chances (OR).
RESULTADOS: Um total de 9 estudos foi incluído na meta-análise. Não houve correlação entre ausência de sobrepeso e cataratas nucleares (OR=1,31, IC 95%: −0,50-3,12, p=0,156). Os resultados do modelo de efeitos aleatórios mostraram que o excesso de peso estava significativamente associado a uma redução do risco de catarata relacionada à idade (OR=0,91, IC 95%: 0,80-1,02, p<0,0001, I2=62,3%, p<0,0001). Houve correlações significativas entre o excesso de peso e cataratas corticais (OR=0,95, IC 95%: 0,66-1,24, p<0,0001), nucleares (OR=0,92, IC 95%: 0,76-1,08, p<0,0001) e subcapsulares posteriores (OR=0,87, IC 95%: 0,38-1,02, p<0,0001) relacionadas à idade. Houve correlações significativas entre obesidade e cataratas corticais (OR=1,00, IC 95%: 0,82-1,17, p<0,0001), nucleares (OR=1,07, IC 95%: 0,92-1,22, p<0,0001) e subcapsulares posteriores (OR=1,14, IC 95%: 0,91-1,37, p<0,0001) relacionadas à idade.
CONCLUSÃO: Estes achados sugeriram uma correlação significativa entre o índice de massa corporal e a catarata relacionada à idade, com o excesso de peso e a obesidade reduzindo e aumentando o risco de catarata relacionada à idade, respectivamente.
Keywords: Envelhecimento; Catarata; Índice de massa corporal; Sobrepeso; Obesidade
Abstract
Objetivo: O efeito regulador do microRNA em doenças tem sido confirmado, e este artigo tentou avaliar a expressão do microRNA-210-3p na catarata relacionada à idade e avaliar o efeito da expressão anormal do miR-210-3p em células SAR01/04 induzidas por H2O2.
Métodos: O método de transcrição reversa seguida de reação em cadeia da polimerase (RT-PCR) quantitativa foi realizado para avaliar os níveis de miR-210-3p em amostras de humor aquoso. Análise de características operacionais do receptor foi feita para avaliar a capacidade de discriminação do miR-210-3p entre pacientes com catarata relacionada à idade e pessoas saudáveis. A análise de correlação de Pearson identificou a correlação do miR-210-3p e índices de estresse oxidativo, como superóxido dismutase, glutationa peroxidase, malonaldeído. O ensaio de contagem de células kit-8 (cck-8) e o ensaio no sistema Transwell foram utilizados para estimar a função biológica do formato de células de catarata relacionada com a idade induzida por H2O2. Os níveis de índices de estresse oxidativo como superóxido dismutase, glutationa peroxidase e malonaldeído foram detectados para avaliar o grau de dano do estresse oxidativo em formato de células de catarata relacionada à idade. A relação entre miR-210-3p e seu gene alvo foi verificada por análise do gene repórter luciferase.
Resultados: A expressão miR-210-3p foi elevada no humor aquoso de pacientes com catarata relacionada à idade. A expressão miR-210-3p altamente expressiva mostrou alto valor diagnóstico para catarata relacionada à idade e foi significativamente associado ao nível de marcadores de estresse oxidativo em pacientes com catarata relacionada à idade. A inibição de miR-210-3p pode reverter a estimulação do estresse oxidativo e os efeitos adversos da função celular induzida por H2O2.
Conclusões: Esses dados sugeriram que a expressão miR-210-3p poderia promover a viabilidade celular, migração celular e estresse oxidativo ao direcionar genes ATG 7 relacionados à autofagia em modelo in vitro de células de catarata relacionadas à idade.
Keywords: Catarata; Fatores etários; Humor aquoso; MiR-210- 3p; Estresse oxidativo; Proteína 7 relacionada à autofagia
Abstract
PURPOSE: To evaluate the saccadic movements of patients with visual field loss due to primary open-angle glaucoma.
METHODS: Thirteen patients with good visual acuity (0.2 logMAR or better) (seven patients with primary open-angle glaucoma 65 ± 13 years) and six controls (51 ± 6 years) yielded a comprehensive ophthalmological examination, including Humphrey Visual Field tests (SITA-Standard 24-2), and performed a monocular, exploratory digital visual search task that quantifies the duration for finding the number “4” on a random array of digits distributed on the screen. After individual adjustments of the angle and distance positioning, the screen was spatially matched with the 24-2 visual field, and divided into five areas for analysis. During the task, saccades were simultaneously recorded in the same eye with a video-based eye tracker.
RESULTS: The patients with primary open-angle glaucoma showed a significantly higher number of saccades/screen (median ± interquartile range, 59.00 ± 29.00 vs. 32.50 ± 19.75 saccades (p=0.027) and visual search time per screen (38.50 ± 60.14 vs. 23.75 ± 8.90 seconds (p=0.035) than the controls did. Although the univariate analysis indicated a significant correlation with visual field mean deviation (coefficient=26.19 (p=0.02), only the visual search time/screen was significantly associated with the number of saccades/screen in the multivariate regression model (coefficient=0.55 (p<0.001). Overall, no significant correlation was observed between the sectorial number of saccades and the sensitivity of the five visual field areas.
CONCLUSIONS: The patients with primary open-angle glaucoma show impaired search performance and showed a higher number of saccades needed to find stimuli when performing the exploratory visual task.
Keywords: Glaucoma, open angle; Saccades; Eye movements; Visual fields; Vision disorders
Abstract
Objetivo: Rever e discutir os tratamentos disponíveis para neovascularização subrretiniana (CNV) secundária a degeneração macular relacionada a idade (DMRI) com ênfase especial a terapia fotodinâmica (PDT). Métodos: Revisamos artigos publicados a partir de 1974 até 1999 relacionados a DMRI, seus tratamentos dispo- níveis e PDT. Resultados: O tratamento provadamente efetivo mais utilizado para CNV é fotocoagulação com laser o qual não apresenta um impacto expressivo na deficiência visual causada pela DMRI. Técnicas alternativas de prevenção e tratamento estão sob investigação incluindo cirurgias, tratamento farmacológico antiangiogênico e prevenção com fotocoagulação. PDT com Verteporfina demonstrou ser efetiva no fechamento de CNV em nosso modelo experimental. Um estudo clínico inicial demonstrou que uma aplicação única poderia estabilizar a área de CNV subfoveal com componente clássico na maioria dos pacien- tes por até 3 meses. Dados de 12 meses em tratamentos quadrimestrais revelaram que a estabilização da visão, significando melhora, não alteração ou perda de até 3 linhas ocorreu em 61,4% dos pacientes tratados e que estes eram menos susceptíveis a perda visual de 6 ou mais linhas (85%) quando comparados com placebo (76%). Outro estudo clínico está em andamento para analisar o PDT em CNV do tipo oculto. Conclusão: O tratamento para esta devastadora patologia continua desafiador. Estes estudos clínicos demonstraram fechamento inicial do CNV com PDT e interessantes resultados em termos de acuidade visual, embora estes resultados necessitem de comprovação clínica a longo prazo. A terapia fotodinâmica é uma das mais promissoras novas tecnologias para o tratamento de CNV.
Keywords: Terapia fotodinâmica; Degeneração macular relacionada a idade; Neovascularização de coróide
Abstract
O treinamento de biofeedback por microperimetria é um método de reabilitação da visão que envolve treinamento de atenção, controle oculomotor e reabilitação do locus preferencial de fixação da retina. Esse treinamento pode melhorar significativamente a acuidade visual para longe e perto na degeneração macular relacionada à idade. Estudos anteriores mostraram que o treinamento de biofeedback usando a nistagmografia elétrica pode reduzir a amplitude do nistagmo e aumentar o período de foveação. Entretanto, os resultados não se mantiveram após o término das sessões. Aqui é relatado um caso de tratamento com biofeedback por microperimetria para melhorar a acuidade visual e a estabilidade de fixação em uma criança de 11 anos de idade. O treinamento teve impacto benéfico e afetou positivamente a estabilidade da fixação e a visão para longe, para perto e de leitura. Subjetivamente, foi relatada melhoria da qualidade de vida. Em contraste com estudos anteriores, os efeitos positivos foram mantidos até 12 meses após a terapia. Até onde sabemos, este é o primeiro caso na literatura que relata benefícios de longo prazo.
Keywords: Nistagmo patológico/reabilitação; locus retiniano preferencial; Baixa visão; Testes de campo visual
Abstract
PURPOSE: This review emphasizes the effect of light on visual efficiency, the impact of different lighting focuses, types of lighting, and their influence on vision and productivity. Light sources and standards are intriguing subjects for ophthalmologists. Guidelines regarding the level of lighting influence on visual activities can enhance visual performance.
METHODS: This article was developed based on literature reviews, with a bibliographic survey conducted in databases such as PubMed, MEDLINE, Web of Science, Embase, LILACS, and SciELO.
RESULTS: Provides recommendations for understanding information regarding the influence of lighting on visual performance.
CONCLUSION: Proper workplace lighting is crucial for improving visual efficiency, safety, productivity, and worker health. Efficient workplace lighting should avoid light sources directed towards the worker's face, prevent harmful glare, be more intense in the work area, and uniform in the rest of the room. Ophthalmologists should be knowledgeable about and provide guidance on correct lighting to ensure patient comfort and satisfaction with visual correction.
Keywords: Visual performance; Lighting; Visual acuity
Abstract
Aging and face sagging have many causes, and various techniques are used for treatment, including noninvasive procedures, such as focused ultrasound, which uses the principle of collagen regeneration by coagulative necrosis of the dermis layers using radiofrequency, but this procedure has complications. We reported a case of a 54-year-old female patient who complained of poor visual acuity in her right eye three days after a focused ultrasound facial aesthetic procedure, with the best visual acuity of 20/60. Biomicroscopy of the right eye revealed an acute cataract with three points of fibrosis extending from the posterior to the anterior capsule. The patient underwent phacoemulsification surgery with visual rehabilitation and improved vision of 20/20. We hypothesized that the occurrence of acute cataract was related to the inappropriate use of focused ultrasound.
Keywords: Cosmetic techniques; Skin aging; Rejuvenation; Ultrasonic therapy/adverse effects; High-intensity focused ultrasound ablation/methods; Cataract/etiology; Phacoemulsification; Lens implantation, intraocular; Visual acuity; Humans; Middle age; Female; Case
ABO is licensed under a Creative Commons Attribution-NonComercial 4.0 Internacional.
About
Issues
Editorial Board
Submission
Official publication of Conselho Brasileiro de Oftalmologia
Rua Casa do Ator, 1.117 - 2º andar - CEP: 04546-004
São Paulo - SP, Brazil
Phone: +55 11 3266-4000