Editorial
Visualizações

Arq. Bras. Oftalmol. 2013; 76 (4): 10.1590/S0004-27492013000400008

Total: 1319

Efeitos da idade sobre a deformação da córnea utilizando o sistema de tonometria de não contato com a câmera de Scheimpflug

Bruno Freitas Valbon1; Renato Ambrósio-Jr.; Bruno Machado Fontes; Milton Ruiz Alves1

DOI: 10.1590/S0004-27492013000400008

RESUMO

OBJETIVO: Correlacionar os parâmetros derivados da deformação da córnea pelo sistema de tonometria de não-contato integrado com a câmera ultra-rápida de Scheimpflug (Oculus Corvis ST, Scheimpflug Technology; Wetzlar, Germany) com a idade de pacientes jovens saudáveis. MÉTODOS: Estudo observacional, retrospectivo envolvendo 89 olhos de 89 pacientes. As imagens de Scheimpflug foram feitas pela câmera acoplada ao sistema de tonometria de não-contato (Corvis ST) em cada paciente e os parâmetros utilizados foram: Deformidade de amplitude (DA), paquimetria, pressão intraocular, 1st A time, tempo de concavidade máxima, 2nd A time, 1st A Length, 2nd A Length, Wing-Dist, raio de curvatura de maior alcance, raio de curvatura normal, Velocidade de entrada (Vin) e de saída (Vout). Estes parâmetros foram correlacionados com a idade. RESULTADOS: A média de idade dos pacientes foi de 27,50 ± 6,30 anos. O tempo de concavidade máxima alcançada da córnea (HC-time) foi o único parâmetro estudado estatisticamente significante correlacionado com a idade (p=0,04, rs=0,18). O valor p das correlações dos parâmetros derivados do Corvis ST e idade foram: DA (p=0,319), pressão intraocular (p=0,854), paquimetria (p=0,066), 1st A time (p=0,959), 2nd A time (p=0,561), 1st Length (0,552), 2nd Length (p=0,697), Wing-Dist (p=0,769), raio de curvatura de maior alcance (p=0,145), curvature radius normal (p=0,513), Vin (p=0,980) e Vout (p=0,592). CONCLUSÃO: Em olhos saudáveis de pacientes jovens, a idade e os parâmetros pressóricos e biomecânicos da deformação da córnea não foram associados, exceto o tempo de concavidade máxima, que é o tempo do início de aplanação até a concavidade máxima alcançada da córnea.

Descritores: Tonometria ocular; Córnea; Biomecânica; Fatores etários

ABSTRACT

PURPOSE: To correlate parameters derived from corneal deformation resulting from non-contact tonometry integrated with an ultra-high-speed (UHS) Scheimpflug camera (Oculus Corvis ST, Scheimpflug Technology; Wetzlar, Germany) with age in normal eyes from young patients. METHODS: Observational, retrospective study involving one eye randomly selected from study participants, totaling 89 healthy eyes. The Scheimpflug images were taken with an ultra-high-speed camera during each measurement by the corvis ST. The deformation amplitude (DA) and other parameters (e.g., pachy apex, intraocular pressure, 1st A time, highest concavity-time, 2nd A time, 1st A Length, 2nd A Length, Wing-Dist, curvature radius highest concavity, curvature radius normal, Vin, Vout) measured by the corvis ST were correlated with age. The Kolmogorov-Smirnov test was applied, and Spearman's correlation test was utilized to evaluate the parameters measured by the Corvis ST and age. RESULTS: Mean patient age was 27.50 ± 6.30 years. The highest concavity-time was the only studied parameter statistically significantly correlated to age (i.e., p=0.04, rs=0.18). All other corvis parameters were not correlated to age. This included DA (p=0.319), intraocular pressure (p=0.854), pachy apex (p=0.066), 1st A time (p=0.959), 2nd A time (p=0.561), 1st Length (0.552), 2nd Length (p=0.697), Wing-Dist (p=0.769), curvature radius HC (p=0.145), curvature radius normal (p=0.513), Vin (p=0.980) and Vout (p=0.592). CONCLUSIONS: In healthy eyes, age and pressure or biomechanics as derived from the Corvis ST parameters were not associated with exception to highest concavity-time, i.e., the time from starting until the highest concavity is reached.

Keywords: Tonometry, ocular; Cornea; Biomechanics; Age factors


THE CONTENT OF THIS ARTICLE IS NOT AVAILABLE FOR THIS LANGUAGE.


Read in English XML Print PDF English
Open Access
Share

How to cite this article:

Valbon BF, Ambrósio-Jr. R, Fontes BM, Alves MR. Efeitos da idade sobre a deformação da córnea utilizando o sistema de tonometria de não contato com a câmera de Scheimpflug. Arq. Bras. Oftalmol. 2013;76(4):229-232. 10.1590/S0004-27492013000400008
Export citation