OBJETIVO: Determinar as características histológicas e biomecânicas de escleras humanas preservadas em glicerol. MÉTODOS: Escleras de ambos os olhos de 55 doadores foram limpas e preservadas com glicerol a 98% sob refrigeração (4 a 8ºC). A amostra foi dividida em grupo controle sem preservação e 5 grupos de 19 escleras com 7, 15, 30, 90 e 180 dias de preservação. Todas as amostras foram submetidas à avaliação histológica e aos testes de tração e distensão. RESULTADOS: A preservação em glicerol não provocou alterações na arquitetura histológica do tecido escleral. A carga média necessária para romper o tecido escleral aumentou com o tempo de preservação segundo uma função sigmóide. Um incremento significativo na resistência mecânica e diminuição da elasticidade do tecido ocorreram após 90 dias de preservação. CONCLUSÕES: A preservação escleral com glicerol mantém a integridade tecidual. O material preservado torna-se menos distensível após 90 dias de preservação. Cirurgiões que usam esclera preservada em procedimentos oftalmológicos devem estar conscientes das propriedades mecânicas do material e levar em conta o tempo de preservação do material.

Descritores: Esclera; Glicerol; Preservação de tecido; Histologia

ABSTRACT

PURPOSE: To determine the histological and biomechanical characteristics of glycerol-preserved human sclera. METHODS: A total of 114 paired human sclerae were cleaned and preserved with 98% glycerol under refrigeration at 4 to 8ºC. The samples were divided into a control group with no preservation and 5 groups of 19 sclerae in 7, 15, 30, 90 and 180 days of preservation. Each specimen was submitted to histological examination and tested for traction distensibility functions. RESULTS: Preservation in glycerol did not cause alterations in the histological architecture of the scleral tissue. The mean load required to break the scleral tissue increased according to preservation time as a sigmoid function. A significant increase in mechanical resistance and decrease in distension of scleral tissue occurred after 90 days of preservation. CONCLUSIONS: Scleral preservation in glycerol keeps tissue integrity. The preserved material is less distensible after 90 days. Surgeons who use sclera in ophthalmic procedures should be aware of the mechanical characteristics of glycerol-preserved sclera and take into account tissue preservation time.

Keywords: Sclera; Glycerol; Tissue preservation; Histology


THE CONTENT OF THIS ARTICLE IS NOT AVAILABLE FOR THIS LANGUAGE.


Read in English XML Print PDF English
Open Access
Share

How to cite this article:

Schirmbeck T, Cruz AAVe. Avaliação biomecânica e histológica de escleras humanas preservadas em glicerol. Arq. Bras. Oftalmol. 2007;70(6):988-990. 10.1590/S0004-27492007000600019
Export citation