Showing of 1 until 15 from 322 result(s)
Search for: Cataract extraction; Retinal perforations/surgery; Epiretinal membrane/surgery; Vitreous body; Axial length, eye; Vitrectomy; Biometry/methods; Diagnostic techniques, ophthalmological; Guidelines as topic.
Abstract
Objetivo: Avaliar a influência do comprimento axial ocular na espessura da camada de fibras nervosas da retina peripapilar e na espessura da camada de células ganglionares-plexiforme interna em olhos saudáveis após correção para efeito de magnificação ocular.
Métodos: Neste estudo transversal, avaliamos 120 olhos de 60 participantes voluntários (míopes, emétropes e hipermétropes). A espessura da camada de fibras nervosas da retina peripapilar e da camada de células ganglionares-plexiforme interna foram medidas usando a tomografia de coerência óptica espectral (OCT)-Cirrus HD-OCT e correlacionada com o comprimento axial ocular. O ajuste para a magnificação ocular foi realizado aplicando a fórmula de Littmann.
Resultados: Antes do ajuste para magnificação ocular, a análise de modelos mistos ajustada por idade demonstrou uma correlação negativa significante entre o comprimento axial e a espessura média da camada de fibras nervosas da retina peripapilar (r=-0,43; p<0,001), espessura da camada de fibras nervosas da retina peripapilar inferior (r=-0,46; p <0,001), espessura da camada de fibras nervosas da retina peripapilar superior (r=-0,31; p<0,05), espessura da camada de fibras nervosas da retina peripapilar nasal (r=-0,35; p<0,001) e espessura média das células ganglionares-plexiforme interna (r=-0,35; p<0,05). No entanto, após a correção do efeito de magnificação, os resultados foram consideravelmente diferentes, revelando apenas uma correlação positiva entre o comprimento axial e a espessura temporal da camada de fibras nervosas da retina(r=0,42; p<0,001). Além disso, demonstramos uma correlação positiva entre o comprimento axial e a espessura média das células ganglionares-plexiforme interna (r=0,48; p<0,001). Todas as outras correlações não foram consideradas estatisticamente significativas.
Conclusão: Antes do ajuste para o efeito de magnificação ocular, o comprimento axial estava negativamente correlacionado com a espessura da camada de fibras nervosas da retina peripapilar e das células ganglionares-plexiforme interna medido pelo Cirrus-OCT. Atribuimos esse efeito à magnificação ocular associada a comprimentos axiais maiores, o que foi corrigido com a fórmula de Littman. Mais estudos são necessários para investigar o impacto da correção da magnificação ocular na acurácia diagnóstica do Cirrus-OCT.
Keywords: Tomografia de coerência óptica; Células ganglionares da retina; Comprimento axial do olho
Abstract
Objetivo: O objetivo deste estudo é comparar as medições de diâmetro corneano de dois dispositivos normalmente utilizados na prática clínica (IOL Master 500 e Atlas topógrafo corneal) para ver se são permutáveis. O fornecimento de informações sobre a permutabilidade de instrumentos poderia eliminar vários testes desnecessários e, consequentemente, reduzir a carga econômica para o paciente e para a sociedade.
Métodos: Nesta série de casos prospectivos e comparativos, a distância do diâmetro corneano foi medida por examinadores independentes utilizando o Topógrafo Atlas (Carl Zeiss Meditec) e o IOL Master 500 (Carl Zeiss Meditec), em um olho de 184 pacientes. A análise estatística foi realizada utilizando o teste t pareado, a correlação Pearson e a análise Bland-Altman para comparar os métodos de medição.
Resultados: As medições médias da distância do diâmetro corneano com o topógrafo Atlas e o IOL Master 500 foram de 12,20 ± 0,44 mm e 12,12 ± 0,41 mm, respectivamente (p<0,001). A diferença média de WTW entre os dois dispositivos foi de 0,07 mm (intervalo de confiança de 95% da diferença média: 0,04 - 0,11 mm). O coeficiente de correlação Pearson entre os dois dispositivos foi de 0,85, p<0,0001. Os limites de concordância de 95% entre os dois dispositivos foram de -0,38 mm a 0,53 mm.
Conclusões: O Atlas topographer e o IOL Master 500 podem ser utilizados permutavelmente em relação à medição do diâmetro corneano, uma vez que a gama de diferenças encontradas é pouco susceptível de afetar a prática clínica e a tomada de decisões.
Keywords: Topografia da córnea; Comprimento axial do olho; Técnicas de diagnóstico oftalmológico; Procedimentos cirúrgicos oftalmológicos.
Abstract
PURPOSE: Standard intravitreal medication dosages are based on an assumed vitreous cavity volume of 4.0-4.5 mL. However, individual variations in vitreous cavity volume may influence both the efficacy and safety of these medications. This study proposes dosage adjustments for intravitreal medications and gases according to axial length and the corresponding vitreous cavity volume.
METHODS: This descriptive study employed reference guidelines that use axial length to estimate the Axial Length-based Volume of the Vitrectomized Space and the Vitreous Volume EXact table for determining dose adjustments across varying eye sizes. Small eyes (axial length 19-22 mm) have an average vitreous cavity volume of 3.5 mL at an axial length of 20.5 mm; standard-sized eyes (22-25 mm) have 4.8 mL at 23.5 mm; large eyes (25-28 mm) have 6.4 mL at 26.5 mm; and extra-large eyes (28-32 mm) have 8.4 mL at 29.5 mm. The medications considered included anti-infectives, anti-VEGFs, complement inhibitors, recombinant proteases, chemotherapy agents, corticosteroids, and medical gases.
RESULTS: Analysis of intravitreal drug concentrations relative to vitreous cavity volume demonstrated notable variability when a standard dose was administered. Small eyes received about 135% of the concentration intended for a standard-sized eye; large eyes received around 75%; and extra-large eyes received under 60%. The recommended dose adjustments are as follows: for small eyes, administer 70-80% of the standard dose; for large eyes, 130-140%; and for extra-large eyes, 170-180%.
CONCLUSIONS: Tailoring intravitreal drug and gas dosages according to axial length and vitreous cavity volume may enhance intraocular drug distribution, potentially improving both safety and therapeutic outcomes.
Keywords: Intravitreal injections; Axial length; Vitreous body; Drug dosage calculations; Pharmacokinetics; Anti-infective agents
Abstract
Objetivo: Criar modelos, em catarata pediátrica, para estimar valores futuros de ceratometria e comprimento axial, com base na ceratometria e no comprimento axial medidos na cirurgia, para previsão do poder da lente intraocular para emetropia em idades futuras.
Métodos: Olhos com catarata bilateral, ceratometria e comprimento axial medidos na cirurgia e pelo menos um exame pós-operatório com medidas de ceratometria e comprimento axial foram considerados para este estudo. Os modelos para estimar futuras ceratometrias e comprimentos axiais foram criados considerando (1) ceratometria e comprimento axial medidos na cirurgia, (2) a inclinação média da regressão logarítmica da ceratometria e comprimento axial criada para cada olho e (3) a idade na cirurgia. A lente intraocular para emetropia em idades futuras pode ser estimada usando esses valores em fórmulas de terceira geração. Os erros de estimativa da ceratometria, comprimento axial e poder da lente intraocular, usando os modelos, também foram calculados.
Resultados: 57 olhos de 29 pacientes preencheram os critérios de inclusão. A idade média na cirurgia e acompanhamento foram de 36,96 ± 32,04 meses e 2,39 ± 1,46 anos, respectivamente. A inclinação média da regressão logarítmica criada para cada olho foi de -3.286 para ceratometria e + 3.189 para o comprimento axial. Os erros médios de estimativa absoluta para ceratometria e comprimento axial foram respectivamente: 0,61 ± 0,54 D e 0,49 ± 0,55 mm, e para o poder da lente intraocular usando as fórmulas SRK-T, Hoffer-Q e Holladay I foram: 2,04 ± 1,73 D, 2,49 ± 2,10 D e 2,26 ± 1,87 D, respectivamente.
Conclusões: Os modelos apresentados podem ser utilizados para estimar o poder da lente intraocular que levaria a emetropia em idades futuras e orientar a escolha do poder da lente intraocular a ser implantada na catarata pediátrica.
Keywords: Catarata; Biometria/métodos; Emetropia; Comprimento axial do olho; Lentes intraoculares; Criança
Abstract
Objetivo: Determinar se o diâmetro axial está associado ao nível educacional em pacientes idosos com catarata que não foram expostos a dispositivos eletrônicos nas duas primeiras décadas de vida.
Métodos: Este estudo transversal foi conduzido em pacientes idosos com catarata na cidade de Campinas, Brasil. Os Pacientes foram divididos em 2 grupos: no Grupo 1 foram incluídos aqueles que completaram, pelo menos, o ensino fundamental (incluindo analfabetos e aqueles com ensino fundamental completo ou incompleto), o que corresponde a 12 anos de escolaridade; no Grupo 2 foram incluídos indivíduos que, pelo menos, estudaram até o ensino médio (incluindo indivíduos com ensino médio completo e superior completo ou superior incompleto). A amostra foi selecionada aleatoriamente com estratificação por sexo e idade. O desfecho principal foi a medida do diâmetro axial.
Resultados: A amostra foi constituída por 472 indivíduos que foram submetidos a cirurgia de catarata. Duzentos e trinta e seis indivíduos (50%) foram alocados no Grupo 1 e duzentos e trinta e seis indivíduos (50%) no Grupo 2. A mediana da idade (IIQ; intervalo) foi 66 (12; 50-89) anos. Duzentos e setenta e dois (57,6%) eram homens e duzentos (42,4%) mulheres, com distribuição simétrica entre os dois grupos. A mediana do diâmetro axial (IIQ; intervalo) foi 22,82 (1,51; 20,34-28,71) mm no Grupo 1 e 23,32 (1,45; 20,51-31,34) mm no Grupo 2 (p<0,001).
Conclusão: Maiores medidas de diâmetro axial foram associadas a níveis educacionais mais elevados em pacientes idosos submetidos a cirurgia de catarata. Tal achado sugere que a miopização relacionada ao aumento de atividades que utilizam a visão de perto é fenômeno que ocorre antes mesmo da exposição a dispositivos eletrônicos.
Keywords: Comprimento axial do olho; Miopia; Biometria; Catarata; Nível de escolaridade; Humanos; Idoso.
Abstract
Objetivos: Rever características epidemiológicas de crianças submetidas a cirurgia de catarata, em centro de referência no estado de São Paulo, Brasil, e fatos associados a atrasos no tratamento.
Métodos: Um total de 240 olhos submetidos a cirurgia de catarata, em 178 crianças, foram revisados neste estudo transversal observacional. Os seguintes aspectos foram analisados: características clínicas e epidemiológicas, sinais apontados pelos pais, teste do reflexo vermelho, olho operado e idade no diagnóstico e na cirurgia.
Resultados: A média de idades na primeira visita e cirurgia de catarata foi de 48.9 meses (DP=50,0 meses) e 64.5 meses (DP=55.4 meses), respectivamente. O sinal mais importante apontado pelos pais foi a leucocoria. O teste do reflexo vermelho foi realizado em dois terços das crianças com resultados anormais em 28%. Histórico familiar de catarata foi evidente em 30 (20,9%) crianças (n=144). Os achados mais prevalentes em termos de histórico de problemas oculares foram: cirurgias oculares prévias em 37 (16,6%) olhos (n= 223), alterações do segmento anterior em 20 (9,0%) olhos (n=221), estrabismo em 21 (9,5%) olhos (n=220) e nistagmo em 38 (24,4%) crianças (n=156).
Conclusões: Uma das causas para o atraso na admissão pode ter sido a falha em realizar o teste do reflexo vermelho, apesar de não ter sido possível verificar se todas as crianças foram submetidas ao exame. A hereditariedade foi o fator mais importante quanto à causa da catarata nessas crianças. A presença de estrabismo e nistagmo mais uma vez aponta para o diagnóstico tardio. Ausência de programas de referência e centros oftalmológicos especializados em crianças, além do número restrito de profissionais de apoio treinados na área e especialistas em oftalmologia pediátrica, foram as barreiras mais importantes para o tratamento adequado da catarata em crianças.
Keywords: Catarata/ congênito; Extração de catarata; Técnicas de diagnóstico oftalmológico ; Baixa visão; Atenção terciária à saúde; Criança
Abstract
Objetivo: Avaliar as alterações da superfície ocular em pacientes com Rosácea, e comparar com grupo controle.
Métodos: Noventa e três indivíduos foram selecionados para este estudo transversal, observacional e não intervencionista, dividido em dois grupos: rosácea (n=40) e controles (n=53). Foram avaliados parâmetros objetivos da superfície ocular (hiperemia conjuntival, estabilidade e volume do filme lacrimal, disfunção da glândula meibomiana, doença do olho seco, coloração da superfície ocular) e comparado indivíduos saudáveis com pacientes com rosácea.
Resultados: 69,23% dos indivíduos com rosácea eram mulheres, com média de idade de 47,34 ± 12,62 anos. Em comparação com controles pareados, não foram evidenciadas diferenças estatisticamente significativas em relação à acuidade visual (p=0,987) e parâmetros do filme lacrimal (altura do menisco lacrimal (p=0,338), tempo de ruptura do filme lacrimal não invasivo (p=0,228), tempo invasivo de ruptura (p=0,471) e teste de Schirmer (p=0,244), bem como hiperemia conjuntival (p=0,106) e coloração com fluoresceína (p=0,489). Associação significativa foi encontrada na avaliação da meibografia (p=0,026), integridade da camada mucosa (p=0,015) e sintomas de superfície ocular (p<0,0001). Pacientes com rosácea também apresentaram alterações importantes na borda palpebral: expressibilidade glandular (p<0,001), padrão de secreção glandular (p<0,001) e telangiectasia (p<0,001).
Conclusão: A disfunção da glândula de Meibômio está frequentemente associada a condições dermatológicas e é caracterizada por achados morfológicos na meibografia, bem como comprometimento da secreção lipídica que leva ao olho seco evaporativo e alterações da superfície ocular e inflamação.
Keywords: Rosácea/complicações; Disfunção da glândula tarsal; Túnica conjuntiva; Síndromes do olho seco; Técnicas de diagnóstico oftalmológico.
Abstract
PURPOSE: Access to cataract treatment and diagnostic tools continues to be hindered by financial and logistical barriers. Thus, photography-based cataract analysis via portable devices offers a promising solution for the detection of cataracts in remote regions. In this study, the accuracy of a portable device that is based on the Lens Opacities Classification III System for diagnosing cataracts was analyzed.
METHODS: Photographs of the anterior segment of the eye were taken in a low-light environment, and the pupillary region markings were automatically delineated using infrared photography. The captured images were automatically analyzed using a convolutional neural network. The study group included patients with cataracts, and the control group included patients without cataracts.
RESULTS:A total of 270 eyes were analyzed, which included 143 eyes with cataracts and 127 control eyes. A total of 599 photos were analyzed. The isolated nuclear cataract was the most frequently detected subtype (37.5%), followed by a nuclear cataract associated with a cortical cataract (30.3%). The device's accuracy was 88.5% (Confidence intervals (CI), 83.19%–94.69%), specificity was 84.62% (CI 71.79%–97.30%), positive predictive value was 91.78% (CI 74.36%–97.30%), and negative predictive value was 82.50% (CI 74.36%–97.30%).
CONCLUSION: The portable device is a simplified user-friendly cataract screening technique that can interpret results in remote regions. This innovation could mitigate the occurrence of cataract-induced blindness and prevent premature surgical interventions in early-stage cataracts.
Keywords: Cataract/diagnosis; Diagnostic techniques ophthalmological/instrumentation; Optical devices; Equipment and supplies; Eye-tracking technology
Abstract
PURPOSE: To compare the refractive prediction error of Hill-radial basis function 3.0 with those of 3 conventional formulas and 11 combination methods in eyes with short axial lengths.
METHODS: The refractive prediction error was calculated using 4 formulas (Hoffer Q, SRK-T, Haigis, and Hill-RBF) and 11 combination methods (average of two or more methods). The absolute error was determined, and the proportion of eyes within 0.25-diopter (D) increments of absolute error was analyzed. Furthermore, the intraclass correlation coefficients of each method were computed to evaluate the agreement between target refractive error and postoperative spherical equivalent.
RESULTS: This study included 87 eyes. Based on the refractive prediction error findings, Hoffer Q formula exhibited the highest myopic errors, followed by SRK-T, Hill-RBF, and Haigis. Among all the methods, the Haigis and Hill-RBF combination yielded a mean refractive prediction error closest to zero. The SRK-T and Hill-RBF combination showed the lowest mean absolute error, whereas the Hoffer Q, SRK-T, and Haigis combination had the lowest median absolute error. Hill-radial basis function exhibited the highest intraclass correlation coefficient, whereas SRK-T showed the lowest. Haigis and Hill-RBF, as well as the combination of both, demonstrated the lowest proportion of refractive surprises (absolute error >1.00 D). Among the individual formulas, Hill-RBF had the highest success rate (absolute error ≤0.50 D). Moreover, among all the methods, the SRK-T and Hill-RBF combination exhibited the highest success rate.
CONCLUSIONS: Hill-radial basis function showed accuracy comparable to or surpassing that of conventional formulas in eyes with short axial lengths. The use and integration of various formulas in cataract surgery for eyes with short axial lengths may help reduce the incidence of refractive surprises.
Keywords: Cataract; Lenses, intraocular; Axial length, eye; Refractive errors; Artificial intelligence
Abstract
OJETIVOS: O olho seco é uma doença multifatorial, muito comum na prática clínica oftalmológica. A utilização de questionários validados de sintomas de olho seco permite rastrear de maneira mais objetiva essa doença na população geral, avaliar a prevalência dos sintomas e frequência de diagnóstico, permitindo o tratamento precoce e adequado dessa condição. O 5-Item Dry Eye Questionnaire (DEQ-5) é um questionário em inglês que avalia a frequência e a intensidade do desconforto e ressecamento ocular e a frequência do lacrimejamento, já validado no inglês e espanhol, porém não no português até o presente momento. O objetivo deste estudo foi traduzir e validar o questionário DEQ-5 para a língua portuguesa.
MÉTODOS: Foi utilizado o questionário DEQ-5, composto por 5 perguntas simples e diretas - 2 relacionadas ao desconforto ocular, 2 ao ressecamento ocular e 1 ao lacrimejamento. Foi realizada a tradução inicial da versão em inglês para o português por dois tradutores de língua materna portuguesa, seguido de uma avaliação e compilação de uma versão única por um comitê interdisciplinar das versões traduzidas. Em seguida, tal versão foi traduzida de volta para o inglês por 2 indivíduos que possuíam o inglês como primeira língua, seguido de avaliação e comparação com a versão original em língua inglesa pelo mesmo comitê interdisciplinar. Após, a versão final do questionário foi aplicada em 31 voluntários em dois momentos diferentes.
RESULTADOS: A confiabilidade interobservador das 5 perguntas variou de 0,584-0,813 e a correlação de Pearson de 0.755-0.935, sendo o p-valor <0,0001 em todas elas. A consistência interna foi α=0,887. Todas as perguntas apresentaram concordância de moderada a alta.
CONCLUSÕES: A análise estatística dos dados coletados encontrou ótimos índices de concordância - moderada a alta para todas as questões analisadas -, permitindo o uso do DEQ-5 na língua portuguesa em pesquisas e também como forma de triagem para doença de olho seco e acompanhamento dos sintomas.
Keywords: Síndromes do olho seco; Técnicas de diagnóstico oftalmológico; Inquéritos e questionários; Traduções
Abstract
Objetivo: Comparar as diferenças entre a chord aparente µ e o chord real µ.
Métodos: Estudo prospectivo, comparativo, não randomizado e não intervencionista. Os exames de imagem (Pentacam e HD Analyzer) foram realizados na mesma sala e nas mesmas condições escotópicas. Os critérios de inclusão foram idade de 21 a 71 anos; compreensão do termo de consentimento; miopia até 4D e astigmatismo topográfico anterior até 1D. Os critérios de exclusão foram usuários de lentes de contato; pacientes com doenças oculares prévias ou cirurgias; opacidades da córnea; a presença de alterações tomográficas da córnea ou suspeita de ceratocone.
Resultados: Em nosso estudo foram analisados 116 olhos de 58 pacientes. A média de idade foi de 30,69 anos (± 7,85). Análises de correlação foram desenvolvidas e o coeficiente de correlação de Pearson (0,647) indica uma relação linear positiva moderada entre as variáveis. A média do chord µ real foi 226,21± 128,53 µm e a média do chord µ média foi 278,66 ± 123,90 µm, com diferença média de 52,45 µm (p=0,01).
A análise do diâmetro pupilar médio apresentou: 5,76mm no HD Analyzer e 3,31mm no Pentacam.
Conclusões: Entendemos a existência de uma diferença significativa entre os métodos e assim a medida de ambos os dispositivos com base em princípios diferentes devemos respeitar suas peculiaridades. Como encontramos correlação entre as duas medidas, acreditamos que ambas podem ser utilizadas na prática diária.
Keywords: Imagem óptica; Percepção visual; Pupila; Segmento anterior do olho; Córnea; Técnicas de diagnóstico oftalmológico
Abstract
Objetivo: A possível variabilidade nos resultados de testes diagnósticos é uma característica estatística dos pacientes com síndrome do olho seco. O médico deve considerar as variações do filme lacrimal ao longo do tempo, pois o momento em que o filme lacrimal é medido pode ser crítico para o diagnóstico adequado. O objetivo deste estudo foi analisar a variação semanal da osmolaridade do filme lacrimal em participantes saudáveis e em outros com síndrome do olho seco.
Métodos: Com base nos critérios da metodologia de diagnóstico do relatório da Dry Eye Workshop II (DEWSII), foi aplicada uma bateria de testes (questionário do índice de doença da superfície ocular [OSDI], tempo de ruptura do filme lacrimal e coloração da córnea) para descartar a presença de síndrome do olho seco. Um total de 40 voluntários qualificados foi recrutado e distribuído em dois grupos de 20 participantes saudáveis e 20 participantes com síndrome do olho seco. A variação da osmolaridade entre semanas foi medida com um osmômetro TearLab em duas sessões com uma semana de intervalo nos dois grupos. As diferenças entre os resultados foram então calculadas.
Resultados: Não foram encontradas diferenças significativas na osmolaridade entre as medidas obtidas nas duas sessões, nem no grupo de participantes saudáveis (teste de t pareado; p=0,085), nem no de participantes com síndrome do olho seco (teste de t pareado; p=0,093). Não foi detectada nenhuma correlação significativa entre as médias e diferenças entre as duas sessões entre participantes saudáveis (correlação de Pearson: r=0,020, p=0,935) e aqueles com síndrome do olho seco (correlação Pearson: r=-0,022, p=0,928). Foi encontrada uma diferença significativa nos valores de osmolaridade entre os dois grupos na primeira sessão (teste de t não pareado; p=0,001), mas nenhuma diferença foi encontrada na segunda sessão (teste de t não pareado; p=0,292).
Conclusões: O presente estudo não encontrou variação entre semanas consecutivas na osmolaridade do filme lacrimal em participantes saudáveis e com síndrome do olho seco, classificados com base nos critérios do DEWSII.
Keywords: Concentração osmolar; Lágrimas; Síndromes do olho seco; Técnicas de diagnóstico oftalmológico
Abstract
Objetivos: Avaliar a segurança e eficácia a longo prazo da vitreólise com Nd:YAG laser para moscas volantes sintomáticas, uma vez que permanece como um procedimento controverso devido a falta de evidência científica robusta sobre a manutenção dos resultados e ocorrência de efeitos adversos.
Métodos: Este estudo é uma extensão observacional de um ensaio clínico prospectivo, randomizado, duplo cego, previamente publicado. Oito de treze pacientes que foram submetidos a vitreólise com YAG laser foram acompanhados para uma reavaliação tardia, dezoito meses após o procedimento, para avaliar a eficácia e segurança do procedimento.
Resultados: Todos os pacientes mantiveram a melhora na sintomatologia notada ao final do procedimento original, com 25% dos casos apresentando melhora completa, e uma proporção semelhante (37,5%) demonstrando melhora significativa ou parcial. A melhora objetiva na opacidade foi similar ao achado no seguimento original de 6 meses. O questionário de qualidade de vida NEI-VFQ 25 não demonstrou diferença estatisticamente significativa nas respostas entre o sexto e o décimo oitavo mês de acompanhamento. Nenhum efeito adverso foi notado no exame clínico ou reportado pelos pacientes.
Conclusão: A eficácia da vitreólise observada ao sexto mês do acompanhamento foi mantida até o décimo oitavo mês, com todos os pacientes notando algum grau de melhora quando comparado ao estado pré procedimento. Nenhum efeito adverso tardio foi notado. Um ensaio clínico randomizado maior é necessário para confirmar a segurança do procedimento.
Keywords: Terapia a laser; Lasers de estado sólido; Vitrectomia; Corpo vítreo; Cirurgia vitreorretiniana; Acuidade visual; Doenças oculares; Qualidade de vida; Inquéritos e questionários
Abstract
PURPOSE: This study aimed to evaluate the efficacy and clinical outcomes of a one-way fluid-air exchange procedure for the treatment of postvitrectomy diabetic vitreous hemorrhage in patients with proliferative diabetic retinopathy.
METHODS: This retrospective study included 233 patients with proliferative diabetic retinopathy, who underwent vitrectomy. A one-way fluid-air exchange procedure was performed in 24 eyes of 24 (10.30%) patients with persistent vitreous cavity rebleeding after the operation. Preprocedural and postprocedural best-corrected visual acuity values were achieved. Complications occurring during and after the procedure were analyzed.
RESULTS: Significant visual improvement was observed 1 month after the one-way fluid-air exchange procedure (2.62 ± 0.60 LogMAR at baseline vs. 0.85 ± 0.94 LogMAR at postprocedure, p<0.0001). Moreover, 19 (79.17%) eyes needed the procedure once, and 5 (20.83%) eyed had the procedure more than twice. In 3 (12.50%) eyes, reoperation was eventually required because of persistent rebleeding despite several fluid-air exchanges. No complication was observed during the follow-up.
CONCLUSIONS: The one-way fluid-air exchange procedure can be an excellent alternative to re-vitrectomy for patients with proliferative diabetic retinopathy suffering from postvitrectomy diabetic vitreous hemorrhage by removing the hemorrhagic contents directly and achieving fast recovery of visual function without apparent complications.
Keywords: Diabetic retinopathy; Vitrectomy; Vitreous body; Vitreous hemorrhage; Hemostatic techniques
Abstract
A young woman presented at our clinic with sudden visual loss in the right eye, recurrent vertigo, and right-sided tinnitus. We performed a complete ophthalmological evaluation. This revealed effects of the condition on the small arterioles of the peripheral retina. Susac syndrome is characterized by the clinical triad of retinal arteriolar occlusions, cochleovestibular manifestations, and encephalopathy (which can be identified by neuroimaging abnormalities). Early diagnosis and immunosuppressive therapy improved the patient’s visual acuity and the remission of her other symptoms. Hemi-central retinal artery occlusion is an atypical neuro-ophthalmological finding in this disease. However, its identification as a sign of Susac syndrome may facilitate timely diagnosis and accurate treatment.
Keywords: Ophthalmological diagnostic techniques; Retinal artery occlusion; Vertigo; Cerebrovascular disorders; Susac syndrome
ABO is licensed under a Creative Commons Attribution-NonComercial 4.0 Internacional.
About
Issues
Editorial Board
Submission
Official publication of Conselho Brasileiro de Oftalmologia
Rua Casa do Ator, 1.117 - 2º andar - CEP: 04546-004
São Paulo - SP, Brazil
Phone: +55 11 3266-4000