Showing of 1 until 15 from 243 result(s)
Search for: Cornea; Lacrimal functional unit; Lacrimal apparatus; Hypersensitivity; Wistar rats; Dry eye syndrome
Abstract
OBJETIVOS: Identificar vasos linfáticos em espécimes orbitários de cadáveres humanos através de microscopia óptica e análise imunohistoquímica.
MÉTODOS: Um estudo postmortem incluiu dez espécimes orbitários provenientes de dez cadáveres humanos. Todos os espécimes orbitários foram obtidos até 12 horas após a morte com uma técnica cirúrgica de exenteração orbitária e dissecados em glândula lacrimal, nervo óptico, gordura órbitária e músculos extraoculares. Para classificar como um vaso linfático, os critérios histológicos incluíram vasos endoteliais de parede única sem membrana basal bem desenvolvida, irregulares e lúmen sem hemácias, e os critérios imunohistoquímicos incluíram vasos endoteliais de parede única, com formato irregular e lúmen sem hemácias e reagentes a podoplanina D2-40.
RESULTADOS: As lâminas histológicas de glândula lacrimal, nervo óptico, tecido adiposo e músculos extraoculares reagiram positivamente a podoplanina D2-40.
CONCLUSÃO: Este estudo demonstrou vasos linfáticos na órbita humana, mais exatamente, na glândula lacrimal, no nervo óptico, na gordura orbitária e nos músculos extrínsecos extraoculares via microscopia óptica e imunohistoquímica.
Keywords: Vasos linfáticos; Órbita; Nervo óptico; Aparelho lacrimal; Músculos oculomotores; Tecido adiposo; Microscopia
Abstract
Objetivo: Descrever as manifestações oftalmológicas observadas em pacientes com artrite psoriásica atendidos no Serviço de Reumatologia da Universidade do Estado do Pará.
Métodos: Estudo transversal. A amostra foi composta por 23 pacientes com artrite psoriásica, segundo os critérios de Caspar, atendidos no ambulatório de reumatologia da Universidade do Estado do Pará. Para avaliação da atividade de doença foi aplicado o Clinical Disease Activity index for Psoriatic Arthritis e, posteriormente, foi realizado o exame oftalmológico (acuidade visual com correção para distância, biomicroscopia, tonometria de aplanação de Goldmann, fundoscopia, teste de Schirmer I, tempo de ruptura do filme lacrimal, lissamina verde e questionário The Ocular Surface Disease Index).
Resultados: Nesta pesquisa não houve predomínio entre os sexos e a população tinha uma mediana de idade de 47,78 anos. As manifestações mais comuns foram olho seco (60,9%), catarata (56,5%), blefarite (47,8%), ceratite (43,5%), meibomite (30,4%) e pterígio (26,1%).
Conclusão: As manifestações oculares encontradas em pacientes com artrite psoriásica são variadas e afetam sobretudo a superfície ocular; no entanto, são clinicamente subestimadas; por isso recomenda-se o acompanhamento oftalmológico regular e periódico para pacientes com artrite psoriásica.
Keywords: Artrite psoriásica; Manifestação ocular; Ceratoconjuntivite seca; Síndrome do olho seco; Blefarite
Abstract
Objetivo: O objetivo deste estudo foi investigar o efeito protetor do cilostazol no desenvolvimento e na evolução da retinopatia diabética em ratos.
Métodos: Sessenta ratos machos foram divididos em 4 grupos: ratos não-diabéticos não-tratados, ratos diabéticos não-tratados, ratos não-diabéticos tratados com cilostazol e ratos diabéticos tratados com cilostazol. A espessura da membrana limitante interna à membrana limitante externa, a camada plexiforme interna, a camada nuclear interna e a camada nuclear externa foram medidas. Para quantificar o grau de perda de células da retina, foi contado o número de núcleos de células por 50 µm de comprimento em secções retinianas.
Resultados: O número de núcleos no GCL foi significativamente maior em Ratos não-diabéticos não-tratados com cilostazol (p<0,05). O número médio de núcleos em Ratos não-diabéticos tratados com cilostazol foi significativamente maior do que em Ratos diabéticos tratados com cilostazol (p<0,05). A contagem média de núcleos em camada nuclear interna e camada plexiforme interna de ratos não-diabéticos tratados com cilostazol foi significativamente maior do que nos outros grupos (p<0,05). A espessura retiniana média total de Ratos não-diabéticos tratados com cilostazol foi significativamente maior do que em Ratos diabéticos tratados com cilostazol e Ratos diabéticos não-tratados (p<0,05).
Conclusão: Os resultados demonstraram que o cilostazol teve um efeito protetor contra as alterações causadas pela retinopatia diabética em ratos diabéticos, diminuindo a perda de células ganglionares e reduzindo a atrofia neurossensorial nas camadas retinianas internas.
Keywords: Cilostazol; Células ganglionares; Retinopatia diabética; Retina; Ratos Wistar.
Abstract
Objetivo: Uma das desvantagens mais importantes do uso de stents Mini Monoka no reparo de lacerações canaliculares pediátricas é a perda prematura do stent. Neste estudo, objetivamos comparar os resultados clínicos dos stents monocanaliculares Mini Monoka e Masterka em crianças e discutir as possíveis causas da perda prematura do stent.
Métodos: Foram incluídos nesta revisão retrospectiva 36 pacientes <18 anos de idade que se submeteram ao reparo cirúrgico de uma laceração canalicular com um stent Mini Monoka ou Masterka e tiveram pelo menos 6 meses de acompanhamento após a remoção do stent. Foram analisados os dados demográficos, o mecanismo da lesão, o tipo de stent utilizado, a ocorrência de perda prematura de stent e o sucesso da intervenção. O sucesso foi definido como a ausência de epífora após a remoção do stent, sem a perda prematura deste.
Resultados: Vinte e sete pacientes preencheram os critérios do presente estudo e foram incluídos nas análises. O stent Mini Monoka foi usado em 14 pacientes (51,9%), enquanto o Masterka foi usado em 13 pacientes (48,1%). As características clínicas pré-operatórias, incluindo idade, sexo e mecanismo de lesão, foram semelhantes entre os dois grupos. A média de idade foi de 8,3 ± 5,5 anos no grupo Mini Monoka e de 7,8 ± 5,9 anos no grupo Masterka (p=0,61). Três pacientes do grupo Mini-Monoka (21,4%) tiveram que ser operados novamente por perda prematura do stent. Nenhuma perda prematura do stent foi observada no grupo Masterka. Como resultado, a taxa de sucesso foi de 78,6% no grupo Mini Monoka e de 100% no grupo Masterka (p=0,22).
Conclusões: Embora nenhuma diferença estatisticamente significativa tenha sido detectada entre os dois grupos em termos de taxas de sucesso, não observamos nenhuma perda prematura de stent no grupo Masterka. São necessários mais estudos, com séries maiores e randomizadas, para chegar a maiores conclusões sobre esses achados.
Keywords: Traumatismos oculares; Aparelho lacrimal/lesões; Ducto nasolacrimal; Lacerações; Stents; Microcirurgia; Intubação/métodos; Laceração canalicular; Criança; Estudo comparativo
Abstract
Objetivo: Comparar as características radiológicas e clínicas do adenoma pleomórfico primário e do carcinoma adenoide cístico da glândula lacrimal.
Métodos: Este estudo revisou retrospectivamente os achados de imagem e os prontuários médicos de casos de adenoma pleomórfico e carcinoma adenoide cístico da glândula lacrimal.
Resultados: Foram avaliados 11 pacientes com adenoma pleomórfico e 16 pacientes com carcinoma adenoide cístico. Não houve diferenças estatisticamente significativas em relação à idade e sexo. Proptose foi o sintoma de apresentação mais comum em ambos os grupos. Os carcinomas adenoides císticos foram mais propensos que os adenomas pleomórficos a apresentarem massas palpáveis, diplopia, dor e perda sensorial, mas essa diferença entre os grupos não foi estatisticamente significativa. Não houve diferenças estatísticas em termos de homogeneidade e indentação do globo ocular entre os dois tipos de tumores em imagens de tomografia computadorizada (p>0,05). Também à tomografia computadorizada, a invasão óssea, a calcificação do tumor e o sinal em cunha foram mais frequentes nos carcinomas adenoides císticos, enquanto a remodelação óssea foi mais frequente nos adenomas pleomórficos, com significância estatística para todas essas manifestações (p<0,05). À ressonância magnética, os adenomas pleomórficos foram significativamente mais propensos a terem margens bem definidas, contornos lobulados, realce heterogêneo pelo contraste e hiperintensidade na ressonância magnética ponderada em T2 (p<0,05).
Conclusão: Ao se diferenciar o adenoma pleomórfico e o carcinoma adenoide cístico da glândula lacrimal, é muito importante avaliar as características radiológicas juntamente com as características clínicas. Os contornos lobulados podem ser uma característica radiológica significativamente distinta em favor do adenoma pleomórfico.
Keywords: Aparelho lacrimal/patologia; Adenoma pleomorfo; Carcinoma adenoide cístico; Tomografia computadorizada por raios x; Imagem por ressonância magnética.
Abstract
OBJETIVO: Comparar os resultados de 3 meses de soro autólogo a 20% com um tratamento combinado, ou seja, lubrificantes oculares sem conservantes e ciclosporina a 0,05% em pacientes com síndrome do olho seco devida à síndrome de Sjögren primária.
MÉTODOS: Foram incluídos no estudo 130 olhos de 65 pacientes recentemente diagnosticados com síndrome do olho seco devida à síndrome de Sjögren primária. Os pacientes foram divididos em dois grupos de tratamento, 66 olhos de 33 pacientes foram incluídos no grupo de tratamento com soro autólogo e 64 olhos de 32 pacientes foram incluídos no grupo de tratamento combinado com lubrificantes oculares sem conservantes e ciclosporina. Os resultados do teste de Schirmer e do tempo de ruptura do filme lacrimal e os índices de doença da superfície ocular (OSDI) foram registrados antes e depois de três meses de tratamento.
RESULTADOS: Três meses após o tratamento, o valor médio do teste de Schirmer foi mais alto com significância estatística no grupo do tratamento combinado com lubrificantes oculares sem conservantes e ciclosporina (p<0,0001) e o tempo de ruptura do filme lacrimal também foi significativamente maior nesse grupo (p=0,034). Também aos três meses, a doença da superfície ocular foi menor com significância estatística no grupo de tratamento com soro autólogo (p=0,004). Quando os dois grupos foram avaliados separadamente, a melhora no teste de Schirmer, o tempo de ruptura e a doença da superfície ocular antes e depois do tratamento tiveram diferenças estatisticamente significativas tanto no grupo de soro autólogo (p<0,0001, p<0,001 e p<0,0001, respectivamente) quanto no grupo de tratamento combinado (p<0,0001, p<0,001 e p<0,0001, respectivamente).
CONCLUSÕES: No tratamento de curto prazo da síndrome do olho seco devida à síndrome de Sjögren primária, o tratamento com soro autólogo foi significativamente superior ao tratamento com lubrificantes oculares sem conservantes combinados com ciclosporina, em termos de melhora no doença da superfície ocular. As melhoras no teste de Schirmer e no tempo de ruptura do filme lacrimal foram significativamente maiores no grupo de tratamento combinado com lubrificantes oculares sem conservantes e ciclosporina.
Keywords: Síndrome de Sjögren/complicações; Síndrome do olho seco/etiologia; Síndrome do olho seco/tratamento farmacológico; Ciclosporina/uso terapêutico; Lubrificantes oftalmológicos
Abstract
This study aimed to evaluate the morphometric and volumetric dimensions of the lacrimal gland in patients with inactive thyroid eye disease and compare them with the values reported in the literature. This case series evaluated consecutive patients with inactive thyroid eye disease treated at a tertiary eye hospital from 2015 to 2020. The patients' baseline demographics and clinical characteristics were obtained. The axial and coronal length, width, and volume of the lacrimal gland were measured on computed tomography scan images, and the results were statistically analyzed. A total of 21 patients (42 orbits) with inactive thyroid eye disease were evaluated. Their mean age was 49.0 ± 14.6 years, and 12 (57.1%) of them were men. The main complaint was dryness, and the majority of the patients had good vision and mild proptosis. The mean axial length and width of the lacrimal gland were 19.3 ± 3.9 mm and 7.5 ± 2.1 mm, respectively; coronal length and width, 20.4 ± 4.5 mm and 7.5 ± 2.1 mm, respectively; and lacrimal gland volume, 0.825 ± 0.326 mm3. Age, sex, or laterality were not found to be determinants of lacrimal gland enlargement. Patients with thyroid eye disease have enlarged lacrimal gland even in the nonactive phase of the disease multifactorial aspects influence the lacrimal gland in thyroid eye disease, making it difficult to establish a clear correlation with predisposing factors. Further studies are warranted to better understand the association between thyroid eye disease and the lacrimal gland.
Keywords: Graves' ophthalmology; Graves' disease; Lacrimal apparatus; Lacrimal apparatus diseases; X-ray computed tomography
Abstract
PURPOSE: The purpose of this study is to assess the long-term outcomes of modified transcanalicular diode laser dacryocys torhinostomy in a large cohort of patients affected by primary acquired nasolacrimal duct obstruction.
METHODS: This study, conducted from January 17 to June 2022, encompassed 141 patients (159 procedures) who underwent modified transcanalicular diode laser dacryocystorhinostomy (MT-DCR). The procedure employed an 810-nm diode laser. Patients were monitored for at least a year after the intervention. Anatomical success was determined by ostium patency upon irrigation, while functional success referred to epiphora resolution. Parameters studied included patient demographics, procedure duration, complications, and both anatomical and functional success. Statistical analysis was performed using the Statistical Package for the Social Sciences software, with results considered significant at a 95% confidence interval (p≤0.05).
RESULTS: A total of 159 lacrimal drainage systems (141 patients: 112 women and 29 men) were included in this study. Among them, 18 underwent bilateral procedures. The average patient age was 58 years (range: 34-91 years), and the average surgical duration was 24 minutes (range: 18-35 minutes). One year after the surgery, MT-DCR exhibited anatomical and functional success rates of 84.9% (135/159) and 83% (132/159), respectively.
CONCLUSION: MT-DCR achieved an anatomical success rate of 84.9%, reflecting an excellent outcome. However, further extensive studies with larger sample sizes and longer follow-up periods are necessary to substantiate these findings.
Keywords: Lacrimal duct obstruction; Nasolacrimal duct/surgery; Dacryocystorhinostomy; Lacrimal apparatus diseases; Laser therapy/methods; Lasers, semiconductor/therapeutic use; Regeneration
Abstract
O relato descreve três casos de síndrome de sicca, inicialmente suspeitos de serem a síndrome de Sjögren, que foram negados pela investigação clínica e laboratorial. O primeiro associado ao uso de isotretinoína, um ácido retinóico, o segundo ao uso de esteroides androgênicos anabolizantes e o terceiro relacionado ao adenoma da hipófise secretora da prolactina, todos manifestaram sicca, incluindo a síndrome do olho seco após esses eventos e as manifestações persistem. A ressonância magnética revelou atrofia bilateral da glândula lacrimal. Eles eram uma mulher de 24 anos, um homem de 32 anos e uma mulher de 77 anos com sintomas crônicos da síndrome de sicca, incluindo a síndrome do olho seco. A história médica, o exame ocular, os exames laboratoriais e a ressonância magnética foram confirmados como síndrome do olho seco, no entanto, todos os exames foram negativos para a síndrome de Sjögren. A glândula lacrimal estava ausente na ressonância magnética nos três casos. A história clínica revelou que sinais e sintomas se manifestaram após exposição crônica ao ácido retinóico, esteróides anabolizantes androgênicos e adenoma secretivo da prolactina hipofisária, respectivamente. Isotretinoína crônica, esteroides anabólicos androgênicos e adenoma hipofisário secretor de prolactina ou, neste último caso, seu tratamento inibitório pode ser a causa da atrofia da glândula lacrimal, síndrome da sicca e síndrome do olho seco e diagnóstico diferencial da síndrome de Sjögren. Estudos adicionais sobre doses, duração e outras suscetibilidades aos efeitos adversos duradouros do ácido retinóico, esteroides androgênicos anabólicos e repercussões do adenoma da hipófise secretora da prolactina são necessários para confirmar e detalhar essas associações.
Keywords: Congêneres da testosterona; Isotretinoína; Síndromes do olho seco; Glândulas lacrimais; Imagem por ressonância magnética; Neoplasias hipofisárias; Adenoma; Prolactina; Síndrome de Sjögren
Abstract
O manejo cirúrgico de grandes tumores envolvendo o fórnice conjuntival pode ser desafiador, onde a exposição e as margens livres podem ser difíceis de serem alcançadas. Nesta série de casos, relatamos nossa experiência inicial com 4 pacientes usando a técnica de livro aberto. Através da cantotomia e da cantólise, esta abordagem cirúrgica fornece um amplo campo cirúrgico e também facilita a reconstrução do fórnice após a excisão de um tumor grande. Em nossa série, um paciente apresentou deiscência no canto lateral.
Keywords: Fornix; Aparelho lacrimal; Neoplasia da conjuntiva
Abstract
A dacriocistite aguda de retenção é uma entidade incomum, o que contribui para que o diagnóstico e o tratamento não sejam corretos. Estamos descrevendo um caso de dacriocistite aguda de retenção ocorrendo em um homem diabético de 61 anos que apresentou dor intensa, edema e sinais inflamatórios acima do tendão cantal medial esquerdo. Ele não tinha histórico anterior de epífora. A tomografia computadorizada indicou dacriocistite aguda. O tratamento clínico resultou na resolução completa da condição. A irrigação, um mês após o episódio agudo, indicou sistema excretor lacrimal pérvio. A obstrução temporária que evoluiu para uma dacriocistite aguda de retenção foi provavelmente secundária a alteração nasal ou supostos dacriolitos. O tratamento clínico conservador pode levar à resolução completa da dacriocistite aguda de retenção, sem necessidade de outros tratamentos.
Keywords: Dacriocistite; Obstrução dos ductos lacrimais; Doenças do aparelho lacrimal; Ducto nasolacrimal
Abstract
O lacrimejamento é um sinal comum na prática oftalmológica, porém frequentemente negligenciado. Os autores descrevem um caso de um paciente com epífora unilateral direita com 8 anos de história que só após evoluir com dacriocistite foi submetido a semiologia de vias lacrimais. Após o diagnóstico de obstrução baixa da via lacrimal foi submetido a cirurgia de dacriocistorrinostomia, onde o saco lacrimal de aparência atípica foi biopsiado e identificado como carcinoma espinocelular. O paciente foi submetido a ressecção oncológica do tumor seguido de radioterapia adjuvante, permanecendo livre de recidiva por 2 anos. Este caso ressalta a importância de investigar causas da epífora, especialmente quando unilateral, dada sua maior associação com a obstrução de via lacrimal. Uma semiologia oportuna das vias lacrimais podem evitar atrasos no diagnóstico de obstrução secundárias a neoplasia, que apesar de incomuns, são potencialmente fatais.
Keywords: Obstrução dos ductos lacrimais; Doenças do aparelho lacrimal; Neoplasias oculares; Carcinoma de células escamosas; Imagem por ressonância magnética; Tomografia computadorizada por raios X; Humano; Relato de casos
Abstract
Descrever um caso de tecido de glândula lacrimal orbitário intracônico e revisar a literatura sobre choristomas lacrimais. Os termos heterotópico, ectópico, aberrante, choristoma e glândula lacrimal foram usados para procurar manuscritos em inglês, espanhol e francês. Todos os artigos encontrados foram revisados. Os choristomas lacrimais relatados foram classificados segundo a localização das lesões, aparência clínica, manejo e desfecho. Imagens de ressonância magnética de um novo caso orbitário comprovado por biópsia também são apresentadas. Foram revisados setenta e nove artigos, de 1887 a 2019, descrevendo 113 casos de choristomas constituídos por tecido de glândula lacrimal normal. Apenas 2 casos (2%) não estavam associados com o olho ou seus anexos. A maioria das 111 lesões restantes foram encontradas na superfície dos olhos (n=46) e nas órbitas (n=34). Os choristomas intraoculares foram encontrados em 18 pacientes. As demais lesões foram diagnosticadas nas pálpebras (n=10) e no sistema lacrimal (n=3). Os choristomas orbitais e intraoculares foram as lesões mais deletérias. Na órbita eles são frequentemente associados com diplopia permanente. Os choristomas lacrimais intraoculares imitam neoplasias e são uma causa comum de enucleação. Os choristomas lacrimais não são incomuns. Este tipo peculiar de lesão já foi induzido experimentalmente uma única vez e pode aparecer em uma variedade de locais associados ao globo e sua anexos. Os choristomas intraoculares têm um prognóstico visual ruim.
Keywords: Glândula lacrimal; Coristoma; Prognostico
Abstract
OBJETIVO: A sondagem lacrimal tem sido o tratamento de escolha para a obstrução lacrimonasal congênita que não apresenta resolução espontânea. Contudo, não há consenso sobre qual é a melhor época para a realização da sondagem e se ela é melhor do que outras terapias. O objetivo foi avaliar a efetividade da sondagem lacrimal no tratamento da obstrução lacrimonasal congênita.
MÉTODO: Uma revisão sistemática da literatura foi realizada usando as plataformas eletrônicas PubMed, EMBASE, CENTRAL, clinicaltrials.gov e LILACS até o período de dezembro de 2019. Foram considerados ensaios clínicos randomizados envolvendo crianças com obstrução lacrimonasal congênita submetidas a sondagem lacrimal. A extração dos dados e avaliação do risco de viés foram feitas por dois autores independentemente. A análise da qualidade da evidência para cada desfecho foi realizada por meio do sistema GRADE (Grading of Recommendations Assessment, Development and Evaluation).
RESULTADOS: Quatro ensaios clínicos randomizados foram incluídos, envolvendo 423 participantes. A metanálise mostrou que não houve diferença estatística na resolução da obstrução lacrimonasal congênita entre o grupo submetido à sondagem lacrimal precoce e o submetido à observação/sondagem tardia (2 estudos; risco médio 1.00 [intervalo de confiança de 95% 0.76, 1.33] p=0,99, I2=79%, baixa certeza de evidência). Um estudo evidenciou melhores resultados da intubação bicanalicular com silicone em comparação a sondagem tardia no subgrupo das obstruções lacrimonasais congênitas complexas, (1 estudo; risco médio 0.56 [intervalo de confiança de 95% 0.34, 0.92] p=0,02, moderada certeza de evidência).
CONCLUSÕES: Há evidências de baixa qualidade de que a sondagem precoce tem a mesma taxa de sucesso que a sondagem tardia. Evidências de moderada certeza sugerem que a sondagem tardia tem menor chance de sucesso do que a intubação bicanalicular com silicone em casos de obstruções lacrimonasais congênitas complexas.
Keywords: Obstrução dos ductos lacrimais/congênito; Obstrução dos ductos lacrimais/terapia; Lactente
Abstract
Uma revisão narrativa da literatura de 57 publicações que descrevem esta patologia, publicada a partir de 2012. Os pacientes têm uma massa de crescimento lento e imóvel, que na maioria das vezes é indolor. Todos os casos foram tratados por excisão total, com exceção de um relatório de radioterapia adjuvante. Entre as estratégias terapêuticas encontradas, a ressecção total do tumor, preservando a pseudocápsula tumoral intacta, parece ser um consenso. Alternativamente, a biópsia por aspiração de agulha fina incluindo a avaliação de alterações genéticas pode representar uma ferramenta valiosa nos casos diagnósticos desafiadores. Uma biópsia incisional antes da cirurgia não é recomendada, pois a ruptura da pseudocápsula aumenta consideravelmente a recorrência do adenoma, permitindo até mesmo sua malignização. Com relação à genética, estudos atuais indicam que as aberrações moleculares envolvidas no adenoma são semelhantes às da patogênese do tumor da glândula salivar. Para casos de recorrência, a patologia torna-se difícil de tratar e múltiplas cirurgias podem ser necessárias, às vezes levando a um tratamento cirúrgico radical.
Keywords: Adenoma pleomorfo; Aparelho lacrimal; Neoplasias da glândulas salivares; Órbita; Biopsia por agulha fina
ABO is licensed under a Creative Commons Attribution-NonComercial 4.0 Internacional.
About
Issues
Editorial Board
Submission
Official publication of Conselho Brasileiro de Oftalmologia
Rua Casa do Ator, 1.117 - 2º andar - CEP: 04546-004
São Paulo - SP, Brazil
Phone: +55 11 3266-4000