Showing of 1 until 15 from 96 result(s)
Search for: Phacoemulsification/adverse effects; Lens implantation, intraocular/adverse effects; Cataract extraction/adverse effects; Lens, capsule; Capsulorhexis
Abstract
OBJETIVO: O objetivo do estudo foi de avaliar as alterações microvasculares da retina e da coroide em pacientes sob hidroxicloroquina, através da angiografia por tomografia de coerência óptica.
MÉTODOS: Este é um estudo transversal de coorte que avaliou um total de 28 olhos de 28 pacientes (24 mulheres e 4 homens) submetidos a tratamento com hidroxicloroquina (grupo da hidroxicloroquina). Catorze olhos de 28 pacientes em uso de hidroxicloroquina por mais de 5 anos foram definidos como sendo o grupo de alto risco, ao passo que o grupo de baixo risco consistiu em 14 olhos de 28 pacientes em uso de hidroxicloroquina por menos de 5 anos. Foram ainda incluídos 28 voluntários como grupo de controle, pareados por idade e sexo. Através de angiografia por tomografia de coerência óptica, foram medidos os seguintes parâmetros: área do fluxo macular (superficial, profundo e coriocapilar), densidade vascular superficial e profunda, área da zona avascular foveal e espessura da coroide subfoveal.
RESULTADOS: Foram recrutados para o estudo um total de 28 pacientes sob tratamento com hidroxicloroquina, com idade média de 45,5 ± 11,1 (29-70) anos, e 28 membros do grupo de controle, pareados por idade e sexo, com idade média de 44,5 ± 13,9 (28-70) anos. As áreas superficial, profunda e coriocapilar do fluxo macular foram respectivamente de 13,578 ± 0,30, 13,196 ± 0,31 e 17,617 ± 0,42 nos pacientes em tratamento com hidroxicloroquina e, respectivamente de 16,407 ± 0,95, 13,857 ± 0,31 e 18,975 ± 0,76 no grupo de controle (p<0,05 para todos os valores). As três medições de área do fluxo macular foram significativamente menores nos pacientes em uso de hidroxicloroquina em comparação com os indivíduos do grupo de controle (p<0,05 para todos os valores). As densidades vasculares superficial e profunda mostraram-se significativamente reduzidas em todas as regiões (foveal, parafoveal, temporal, superior, nasal e inferior) nos pacientes em uso de hidroxicloroquina (p<0,05 para todos os valores). Finalmente, também foi observada uma diferença significativa entre os grupos em relação à área da zona avascular foveal (superficial e profunda), à espessura foveal central e à espessura da coroide subfoveal (p<0,05 para todos os valores).
CONCLUSÃO: O fluxo microvascular retinocoroidal e a densidade vascular da área macular mostraram-se significativamente diminuídos nos pacientes sob hidroxicloroquina. Este fármaco pode danificar a arquitetura microvascular retinocoroidal e a angiografia por tomografia de coerência óptica pode contribuir para a detecção precoce da toxicidade retiniana induzida pela hidroxicloroquina.
Keywords: Retina/efeitos dos fármacos; Coroide/efeitos de fármacos; Tomografia de coerência óptica; Hidroxicloroquina; Angiofluoresceinografia/métodos
Abstract
OBJETIVO: O objetivo deste estudo foi analisar a segurança do implante de lente intraocular primária em um grande número de olhos em crianças <24 meses.
MÉTODOS: Foram revisados os prontuários de pacientes com idade entre 5-24 meses, submetidos a implante primário de lente intraocular no saco capsular. Uma lente intraocular acrílica de três peças dobrável foi implantada pelo mesmo cirurgião usando uma única técnica cirúrgica. Pacientes que tiveram <1 ano de acompanhamento após a cirurgia foram excluídos. Os principais resultados incluíram medidas de acuidade visual, mudança miópica, complicações pós operatórias e cirurgias adicionais.
RESULTADOS: Foram analisados 68 pacientes (93 olhos). A média de idade dos pacientes no momento da cirurgia foi de 15,06 ± 6,19 (5 a 24) meses, e o equivalente esférico 1 mês após a cirurgia foi de 3,62 ± 2,32 D. Após 5,67 ± 3,10 anos, o equivalente esférico foi de -0,09 ± 3,22 D, e a acuidade visual corrigida à distância foi de 0,33 ± 0,33 e 0,64 ± 0,43 logMAR em casos bilaterais e casos unilaterais, respectivamente (p=0,000). A maior mudança míopica foi observado em bebês submetidos à cirurgia aos 5 e 6 meses de idade. As complicações mais frequentes incluíram opacificação do eixo visual e corectopia. Glaucoma e descolamento de retina não foram relatados.
CONCLUSÃO: O implante primário de lente intraocular no saco capsular em crianças de 5-24 meses é seguro e está associado à baixas taxas de eventos adversos e cirurgias adicional.
Keywords: Catarata pediátrica; Lente intraocular; Implante primário LIO; Mudança miópica; Catarata congênita
Abstract
Objetivo: Avaliar a superfície ocular e a morfologia da glândula meibomiana em usuários de cigarros eletrônicos.
Métodos: Foram avaliadas através de meibografia Sirius as pálpebras superiores e inferiores de 25 usuários de cigarros eletrônicos do sexo masculino e 25 pacientes não usuários saudáveis, também do sexo masculino. A perda nas glândulas meibomianas foi calculada automaticamente com o módulo de software de imagem de meibografia Phoenix. O resultado foi obtido como perda percentual. O questionário Ocular Surface Disease Index (OSDI), o teste do tempo de ruptura lacrimal e o teste de Schirmer II foram administrados em todos os casos.
Resultados: A duração média do uso de cigarros eletrônicos foi de 4,9 ± 0,9 anos (intervalo de 3,4-7 anos). O valor médio do teste de Schirmer II foi de 9,16 ± 2,09 mm no grupo de usuários de cigarros eletrônicos e de 11,20 ± 2,14 mm no grupo controle (p=0,003). O valor médio do teste do tempo de ruptura lacrimal foi de 6,96 ± 2,31 segundos no grupo de usuários de cigarros eletrônicos e 9,84 ± 2,13 segundos no grupo controle (p=0,002). O valor médio do Ocular Surface Disease Index foi de 28,60 ± 6,54 e 15,16 ± 7,23 para os grupos de usuários de cigarros eletrônicos e controle, respectivamente (p<0,001). Na meibografia de Sirius, a perda média para a pálpebra superior foi de 23,08 ± 6,55% para o grupo de usuários de cigarros eletrônicos e 17,60 ± 4,94% para o grupo controle (p=0,002), e a perda média para a pálpebra inferior foi de 27,84 ± 5,98% e 18,44 ± 5,91%, respectivamente (p<0,001). Além disso, foi observada uma correlação positiva significativa entre a taxa de perda na meibografia palpebral superior e inferior com a duração do tabagismo eletrônico, respectivamente de (r=0,348, p<0,013) e (r=0,550, p<0,001).
Conclusão: O uso prolongado de cigarros eletrônicos causa danos às glândulas meibomianas. Portanto, esses danos devem ser considerados em distúrbios da superfície ocular devidos ao uso desses dispositivos.
Keywords: Sistemas eletrônicos de liberação de nicotina; Glândulas tarsais; Disfunção da glândula tarsal/diagnostico; Fumar/efeitos adversos; Vaping/efeitos adversos; Técnicas de diagnóstico oftalmológico.
Abstract
Objetivo: O objetivo deste estudo foi analisar dados epidemiológicos de pacientes e resultados laboratoriais para todas as amostras de córnea coletadas de pacientes atendidos no Departamento de Oftalmologia do Hospital São Paulo, Brasil, durante um período de 30 anos e correlacionar com o uso de lentes de contato.
Métodos: Amostras de córnea de pacientes com diagnóstico clínico de ceratite microbiana (de janeiro de 1987 a dezembro de 2016) foram incluídas neste estudo. Resultados laboratoriais para culturas positivas para bactérias, fungos e Acanthamoeba spp. foram analisados retrospectivamente. Para verificar se o número de pacientes com ceratite microbiana associada à lente de contato, fator de risco para infecção microbiana, mudou ao longo do tempo, a análise foi dividida em três décadas: 1987-1996, 1997-2006 e 2007-2016. As informações incluindo o sexo do paciente, idade e tipo de organismo isolado foram comparadas entre os períodos. A análise estatística foi realizada no software SAS/STAT 9.3 e SPSS (v20.0).
Resultados: Amostras de córnea de 10.562 pacientes com ceratite microbiana foram incluídas no estudo, das quais 1.848 foram relacionadas ao uso de lentes de contato. Os resultados revelaram que a frequência de ceratite microbiana associada à lente de contato aumentou nas últimas duas décadas analisadas. No geral, os homens compreendiam uma proporção maior do grupo ceratite microbiana não associada à lente de contato (CMNLC) (60,3%) e as mulheres eram mais frequentes no grupo ceratite microbiana associada à lente de contato (59,5%). Pacientes com idade entre 19 e 40 anos foram mais frequentemente observados no grupo ceratite microbiana associada à lente de contato em todos os períodos. Staphylococcus spp. foi a bactéria Gram-positiva mais frequentes, enquanto Pseudomonas spp. foi a bactéria Gram-negativa nos grupos ceratite microbiana. Entre os fungos ceratite microbiana, os fungos filamentosos foram os fungos mais frequentes durante todo o período do estudo, com Fusarium spp. sendo o mais frequente no grupo ceratite microbiana não associada à lente de contato. Acanthamoeba spp. e Pseudomonas spp. amostras positivas foram significativamente correlacionadas com ceratite microbiana associada à lente de contato.
Conclusões: A maior prevalência de ceratite microbiana associada à lente de contato no nosso estudo foi observada em mulheres e adultos jovens com idade entre 19 e 40 anos. Staphylococcus spp. e Fusarium spp. foram as bactérias e fungos predominantes isolados nas amostras da córnea. Pseudomonas spp. e Acanthamoeba spp. foram significativamente correlacionados a ceratite microbiana associada à lente de contato neste estudo.
Keywords: Lentes de contato/efeitos adversos; Infecções oculares bacterianas/microbiologia; Ceratite por Acanthamoeba; Úlcera de córnea
Abstract
PURPOSE: The purpose of this study was to assess visual outcomes and patient satisfaction following cataract surgery involving the implantation of quad-loop intraocular lenses, including trifocal, bifocal, and toric variants.
METHODS: Information was obtained from both physical and electronic medical records of patients who underwent phacoemulsification cataract surgery with implantation of different intraocular lenses between January 1, 2022, and December 31, 2023. The study included individuals aged over 18 who received bilateral implantation of bifocal, trifocal, or monofocal toric intraocular lenses. Visual acuity was assessed at various postoperative time points using the logMAR scale. Quantitative variables were analyzed using mean and standard deviation.
RESULTS: A total of 92 eyes received premium intraocular lenses: 4 bifocal, 32 trifocal, 52 toric monofocal, and 4 trifocal toric lenses. The average preoperative corrected visual acuity was logMAR 0.478 ± 0.259. On the first postoperative day, the average uncorrected visual acuity was logMAR 0.301 ± 0.207. By day 30, 67.4% of eyes achieved uncorrected distance visual acuity of logMAR 0.2 or better. Patient satisfaction was high, with few reports of glare or halos.
CONCLUSION: Quad-loop intraocular lenses-including trifocal, bifocal, and toric models-demonstrated effective improvement in visual acuity and high levels of patient satisfaction. These lenses represent a suitable option for enhancing visual outcomes after cataract surgery. Additional studies with larger cohorts are recommended to confirm these results.
Keywords: Cataract extraction; Aberrometry/methods; Lenses, intraocular; Lens implantation, intraocular; Prosthesis design
Abstract
PURPOSE: Endophthalmitis is one of the most important adverse events after cataract surgery, as it can lead to total vision loss. This study aimed to describe the occurrence of endophthalmitis after phacoemulsification with intraocular lens implantation in patients treated in a community setting in Porto Velho, Rondônia, Brazil.
METHODS: This retrospective cohort study was conducted using a database of 649 medical records of patients who underwent surgery and were followed for three months. Poisson regression analysis was used to estimate relative risks and 95% confidence intervals (95% CIs).
RESULTS: The incidence of confirmed endophthalmitis was 11.94% (95% CI, 9.50-14.76), while the incidence of confirmed and probable cases was 20.50% (95% CI, 17.52-23.73). For confirmed cases, bilateral surgery and the use of lens model 3 were identified as risk factors for endophthalmitis, whereas age over 70 yr and preoperative antibiotic use were protective factors. For confirmed and probable cases, brown and yellow skin color, bilateral surgery, and the use of lens model 3 were also identified as risk factors. Gram-negative bacteria were the predominant etiological agents, and corneal edema was the main clinical manifestation. The mean duration of treatment was eight days, and 27.12% of patients used antibiotics.
CONCLUSION: The incidence observed was substantially higher than that reported in the literature, with a predominance of Gram-negative agents and an association with bilateral surgeries and the Eyeol intraocular lens model. These findings reinforce the need for continuous epidemiological surveillance and the implementation of specific biosafety and infection control protocols during cataract surgery campaigns.
Keywords: Endophthalmitis; Disease outbreaks; Phacoemulsification; Lens implantation, intraocular; Lenses, intraocular; Cataract; Risk factors; Anti-bacterial agents
Abstract
PURPOSE: We developed an artificial intelligence program for calculating intraocular lenses and analyzed its accuracy rate via ultrasonic biometry. This endeavor is aimed at enhancing precision and efficacy in the selection of intraocular lenses, particularly in cases where optical biometry is unavailable.
METHODS: Data was collected from the Hospital de Clínicas de Porto Alegre, which included cases of phacoemulsification with intraocular lens implantation, in which the lens selection was based on ultrasonic biometry. The program, implemented in Python, Java, and PHP, employs the ridge regression method. Two design options were developed: a basic model, which uses only keratometry variables (K1 and K2), axial size and final target refraction in the spherical equivalent, and an advanced model, which incorporates preoperative refraction and the patient's age. The Universal Barrett II formula was used to compare both models.
RESULTS: The sample consisted of 486 eyes from 313 patients, with 350 eyes used for program training and 136 for program validation. The spherical equivalent hit rates, with a variation of ±0.5 D, were 86% and 87.5% for the basic and advanced models, respectively, with no statistically significant difference between them. With the Barret Universal II formula, the success rate was 69%, which was significantly different from the values of the two aforementioned models (p<0.0001). The system was better for medium and long eyes but worse for short eyes (<=22.00 mm).
CONCLUSION: The developed artificial intelligence program was superior to the Barrett formula in terms of performance, in the general context and within the subgroup of patients with longer eyes. This innovation can considerably contribute to the selection of intraocular lenses, particularly in cases where optical biometry is unavailable.
Keywords: Biometry; Intraocular lens; Cataract; Artificial intelligence
Abstract
The advantages and disadvantages of using perioperative subconjunctival steroid injections in dropless cataract surgery continue to be debated. A systematic review of PubMed, EMBASE, and the Cochrane Central database identified five studies—two randomized controlled trials and three non-randomized studies—encompassing 70,751 eyes. Among these, 12,319 eyes (17.4%) received subconjunctival steroid injections, while 58,432 eyes (82.6%) were managed with topical steroids. The Cochrane Collaboration’s RoB 2 tool was applied for bias assessments in randomized controlled trials, and heterogeneity was assessed using the I² statistics. No statistically significant differences were found between the two groups regarding macular edema (p=0.249), visual acuity (p=0.73), or laser flare count (p=0.45). Both subconjunctival injections and topical steroids demonstrated comparable efficacy and safety in controlling postoperative inflammation after cataract surgery. Additional research is warranted to validate these conclusions.
Keywords: Cataract extraction; Phacoemulsification; Lens implantation, intraocular; Postoperative care; Intravitreal injections; Anti-inflammatory agents, non-steroidal/administration & dosage; Glucocorticoids; Triamcinolone acetonide; Research design; Randomiz
Abstract
PURPOSE: To compare endothelial corneal cell changes following cataract surgery performed by phacoemulsification with intraocular lens implantation, conducted by surgeons with varying levels of experience.
METHODS: Two hundred and eighty-three eyes diagnosed with cataract were included. Lens opacity was classified into three categories (I, II, and III). Surgeons were categorized into four experience levels (1, 2, 3, and 4), based on years of practice and lifetime surgeries performed. Corneal endothelial characteristics were assessed using non-contact specular microscopy, with measurements taken before surgery and 30-60 days post-surgery.
RESULTS: Pre- and postoperative endothelial analysis showed no significant differences between surgeon levels regarding visual acuity achieved, corneal thickness, and endothelial hexagonality. However, the central endothelial cell density index showed a significantly greater reduction among level 1 surgeons (p=0.026). Grade II cataracts exhibited significant variations in the central endothelial cell density (p=0.011) and average cell size, with level 1 surgeons showing the largest increases (p=0.024).
CONCLUSIONS: The analysis revealed significant differences in visual acuity and endothelial indices between surgeon experience levels, with less experienced surgeons showing greater variations and poorer performance. Clinical protocols should consider these data to establish safer training protocols.
Keywords: Cataract extraction; Phacoemulsification; Endothelium; corneal; Lens implantation, intraocular; Visual acuity; Internship and residency; Surgeons
Abstract
Os benzodiazepínicos são medicamentos psicoativos prescritos em todo o mundo, mas com poucas informações sobre seus efeitos colaterais oculares. O glaucoma por fechamento agudo do ângulo iridocorneano é um dos eventos adversos com maior risco de cegueira, sendo descrito particularmente em idosos. Relatamos aqui dois pacientes com menos de 45 anos de idade, com fechamento agudo do ângulo bilateral secundário ao uso de dois diferentes benzodiazepínicos de meia-vida longa (clonazepam e alprazolam). Além da suspensão dessas medicações e do tratamento clínico com drogas hipotensoras oculares, ambos os casos alcançaram sucesso com iridotomias periféricas bilaterais à laser. Considerando o conhecimento atual, estes são os primeiros relatos de fechamento agudo do ângulo bilateral secundária ao uso de clonazepam e alprazolam.
Keywords: Benzodiazepinas/efeitos adversos; Glaucoma de ângulo fechado/ induzido quimicamente; Iridectomia; Lasers
Abstract
Analisamos as amostras das cápsulas anteriores do cristalino de uma paciente com esclerose sistêmica e comparamos com as de um paciente controle. Não foram observadas diferenças significativas entre esclerose sistêmica e controle nos resultados da coloração com hematoxilina-eosina e picrosirius. Nas amostras obtidas da esclerose sistêmica e do controle, obtivemos expressão de caspase, uma molécula expressa na morte celular por apoptose. A heparinase foi expressa de forma mais marcante na amostra de esclerose sistêmica quando comparada ao controle. Portanto, a cápsula anterior do cristalino da paciente com esclerose sistêmica provavelmente foi afetada pela doença, uma vez que mostrou expressão aumentada de heparinase 1.
Keywords: Cápsula do cristalino; Escleroderma sistêmico; Heparinase; Heparina Liase
Abstract
Uma paciente de 62 anos procurou nosso ambulatório com queixas de equimose periorbital e hemorragia subconjuntival, visíveis principalmente no olho direito. Descobrimos que suas queixas começaram no dia seguinte a um tratamento para dor de cabeça com sanguessugas na área da glabela. Na glabela, 2 mordidas de sanguessuga foram encontradas próximas ao lado direito. Durante os exames da paciente, foram detectadas equimoses nas pálpebras bilaterais e hemorragia subconjuntival no limbo ínfero lateral e medial do olho direito. Nenhum tratamento foi iniciado, sendo recomendado apenas controle. No acompanhamento, observou-se que as queixas da paciente desapareceram em cerca de um mês.
Keywords: Cefaléia/terapia;Hirudo medicinalis;Aplicação de sanguessugas/efeitos adversos; Doenças orbitárias; Hematoma; Túnica conjuntiva; Hemorragia ocular/etiologia
Abstract
We present a case report detailing the successful phacoemulsification surgery with artificial iris implantation for two individuals with oculocutaneous albinism. These women suffered from cataracts, resulting in reduced visual acuity and heightened photophobia due to iris pigmentary epithelium deficiency. The patients underwent phacoemulsification along with prosthetic artificial iris implantation into the posterior chamber. This intervention resulted in improved visual acuity, reduced photophobia and glare, and an overall enhanced quality of life. Our report highlights two cases of successful phacoemulsification and artificial iris implantation in patients with oculocutaneous albinism and cataracts, leading to improved visual acuity, reduced photophobia, and enhanced quality of life. Notably, there are no prior records in South American literature of cataract surgery combined with artificial iris implantation for oculocutaneous albinism patients up to the time of this publication.
Keywords: Cataract extraction; Albinism, oculocutaneous; Lens implantation, intraocular
Abstract
Um homem de 59 anos apresentou embaçamento visual unilateral no olho esquerdo. Sua acuidade visual nesse olho era no nível de movimentos da mão. O paciente havia se submetido a uma cirurgia de facoemulsificação em que foi feita a implantação intraestromal de uma lente intraocular de câmara posterior. Foi feita a extração dessa lente intraestromal intraocular e uma nova lente intraocular foi implantada. A melhor acuidade visual corrigida final foi de 20/40 pela tabela de Snellen. Com este relato de caso, os autores desejam apontar que uma incisão de degrau único em córnea clara, quando combinada com a injeção de uma lente ocular através da incisão, pode levar a um direcionamento incorreto da lente intraocular para dentro do estroma corneano. Portanto, recomenda-se uma construção cuidadosa da incisão ao se remover uma lente intraocular direcionada incorretamente.
Keywords: Implante de lente intraocular; Lentes intraocular; Facoemulsificação; Cicatrização; Catarata; Acuidade visual
Abstract
Aging and face sagging have many causes, and various techniques are used for treatment, including noninvasive procedures, such as focused ultrasound, which uses the principle of collagen regeneration by coagulative necrosis of the dermis layers using radiofrequency, but this procedure has complications. We reported a case of a 54-year-old female patient who complained of poor visual acuity in her right eye three days after a focused ultrasound facial aesthetic procedure, with the best visual acuity of 20/60. Biomicroscopy of the right eye revealed an acute cataract with three points of fibrosis extending from the posterior to the anterior capsule. The patient underwent phacoemulsification surgery with visual rehabilitation and improved vision of 20/20. We hypothesized that the occurrence of acute cataract was related to the inappropriate use of focused ultrasound.
Keywords: Cosmetic techniques; Skin aging; Rejuvenation; Ultrasonic therapy/adverse effects; High-intensity focused ultrasound ablation/methods; Cataract/etiology; Phacoemulsification; Lens implantation, intraocular; Visual acuity; Humans; Middle age; Female; Case
ABO is licensed under a Creative Commons Attribution-NonComercial 4.0 Internacional.
About
Issues
Editorial Board
Submission
Official publication of Conselho Brasileiro de Oftalmologia
Rua Casa do Ator, 1.117 - 2º andar - CEP: 04546-004
São Paulo - SP, Brazil
Phone: +55 11 3266-4000