Showing of 1 until 15 from 355 result(s)
Search for: Keratoprosthesis; Corneal diseases; Visual prosthesis; Optical coherence tomography; Anterior eye segment
Abstract
Objetivo: Avaliar a influência do comprimento axial ocular na espessura da camada de fibras nervosas da retina peripapilar e na espessura da camada de células ganglionares-plexiforme interna em olhos saudáveis após correção para efeito de magnificação ocular.
Métodos: Neste estudo transversal, avaliamos 120 olhos de 60 participantes voluntários (míopes, emétropes e hipermétropes). A espessura da camada de fibras nervosas da retina peripapilar e da camada de células ganglionares-plexiforme interna foram medidas usando a tomografia de coerência óptica espectral (OCT)-Cirrus HD-OCT e correlacionada com o comprimento axial ocular. O ajuste para a magnificação ocular foi realizado aplicando a fórmula de Littmann.
Resultados: Antes do ajuste para magnificação ocular, a análise de modelos mistos ajustada por idade demonstrou uma correlação negativa significante entre o comprimento axial e a espessura média da camada de fibras nervosas da retina peripapilar (r=-0,43; p<0,001), espessura da camada de fibras nervosas da retina peripapilar inferior (r=-0,46; p <0,001), espessura da camada de fibras nervosas da retina peripapilar superior (r=-0,31; p<0,05), espessura da camada de fibras nervosas da retina peripapilar nasal (r=-0,35; p<0,001) e espessura média das células ganglionares-plexiforme interna (r=-0,35; p<0,05). No entanto, após a correção do efeito de magnificação, os resultados foram consideravelmente diferentes, revelando apenas uma correlação positiva entre o comprimento axial e a espessura temporal da camada de fibras nervosas da retina(r=0,42; p<0,001). Além disso, demonstramos uma correlação positiva entre o comprimento axial e a espessura média das células ganglionares-plexiforme interna (r=0,48; p<0,001). Todas as outras correlações não foram consideradas estatisticamente significativas.
Conclusão: Antes do ajuste para o efeito de magnificação ocular, o comprimento axial estava negativamente correlacionado com a espessura da camada de fibras nervosas da retina peripapilar e das células ganglionares-plexiforme interna medido pelo Cirrus-OCT. Atribuimos esse efeito à magnificação ocular associada a comprimentos axiais maiores, o que foi corrigido com a fórmula de Littman. Mais estudos são necessários para investigar o impacto da correção da magnificação ocular na acurácia diagnóstica do Cirrus-OCT.
Keywords: Tomografia de coerência óptica; Células ganglionares da retina; Comprimento axial do olho
Abstract
Objetivo: Comparar os resultados anatômicos e visuais da cirurgia com peeling da membrana epirretiniana idiopática na presença e ausência de herniação foveal.
Métodos: Estudo retrospectivo, comparativo, de dois centros. Pacientes com membrana epirretiniana idiopática pareados por idade e sexo com herniação foveal (grupo membrana epirretiniana + herniação foveal) e sem herniação foveal (grupo apenas com membrana epirretiniana) foram incluídos. Mudanças na acuidade visual melhor corrigida e espessura foveal central em todos os pontos de acompanhamento foram comparadas entre os grupos. A linha de base da melhor acuidade visual corrigida e a espessura foveal central foram comparadas dentro dos grupos no 1º, 3º, 6º e 12º meses de acompanhamento após a cirurgia.
Resultados: Dezesseis pacientes com membrana epirretiniana + olhos com herniação foveal e 16 pacientes com olhos apenas com membrana epirretiniana foram incluídos no estudo. Não houve diferença significativa entre os grupos na linha de base com melhor acuidade visual corrigida e espessura foveal central (p>0,05), exceto para a melhor acuidade visual corrigida do grupo da membrana epirretiniana após o 1º mês (p> 0,05), a melhor acuidade visual corrigida e a espessura foveal central melhoraram significativamente em ambos os grupos em todos os acompanhamentos em comparação com a linha de base (p<0,05). A média da melhor acuidade visual corrigida melhorou após o 1º mês e a redução média da espessura foveal central após o 1º, 3º e 6º meses foram significativamente melhores no grupo de herniação foveal + membrana epirretiniana do que no grupo com apenas membrana epirretiniana (p<0,05). Não houve diferença significativa na melhor acuidade visual corrigida e nas alterações da espessura foveal central entre os grupos na visita final (p>0,05).
Conclusões: Embora uma melhora anatômica e funcional bem mais precoce tenha sido mostrada no grupo membrana epirretiniana + herniação foveal, a presença de herniação foveal não afetou os resultados cirúrgicos finais em pacientes com membrana epirretiniana idiopática.
Keywords: Membrana epirretiniana; Tomografia de coerência óptica; Fóvea central; Vitrectomia; Acuidade visual
Abstract
PURPOSE: To determine the clinical outcomes in patients after type 1 Boston keratoprosthesis surgery and the significance of ultrasound biomicroscopy imaging for postoperative follow-up.
METHODS: This retrospective analysis included 20 eyes of 19 patients who underwent corneal transplantation with type 1 Boston keratoprosthesis between April 2014 and December 2021. Data on patient demographics, preoperative diagnosis, visual acuity, and postoperative clinical findings were analyzed.
RESULTS: Type 1 Boston keratoprosthesis implantation resulted in intermediate- and long-term positive outcomes. However, blindness and other serious complications such as glaucoma, retroprosthetic membrane formation, endophthalmitis, or retinal detachment also occurred. The use of ultrasound biomicroscopy imaging allowed for better evaluation of the back of the titanium plate, anterior segment structures, and the relationship of the prosthesis with surrounding tissues, which provided valuable postoperative information.
CONCLUSION: Regular lifetime monitoring and treatment are necessary in patients who undergo Boston type 1 keratoprosthesis implantation for high-risk corneal transplantation. ultrasound biomicroscopy imaging can be a valuable imaging technique for the evaluation of patients with Boston type 1 keratoprosthesis, providing important information on anterior segment anatomy and potential complications. Further studies and consensus on postoperative follow-up protocols are required to optimize the management of patients with Boston type 1 keratoprosthesis.
Keywords: Boston Keratoprosthesis; Corneal transplantation; Ultrasound biomicroscopy; Anterior segment; Prostheses and implants
Abstract
Objetivo: Os efeitos dos hormônios esteróides sexuais nos parâmetros lacrimais são conhecidos. O objetivo deste estudo foi examinar como os efeitos nos parâmetros lacrimais durante a exposição a altas doses de esteróides sexuais em um curto período de tempo.
Métodos: Quarenta pacientes que foram admitidas na clínica de infertilidade do nosso hospital e planejavam a indução de ovulação por gonadotropinas exógenas. Antes do início da indução da ovulação, os níveis basais de estradiol foram medidos no terceiro dia do ciclo menstrual e os exames oftalmológicos foram efetuados pelo Departamento de Oftalmologia do nosso hospital. Os níveis de estradiol foram medidos no dia da indução da ovulação usando gonadotrofina coriónica humana e comparados aos estradiol basal; exames oftalmológicos também foram repetidos.
Resultado: Quarenta mulheres com período reprodutivo e idade média de 33,3 ± 4,2 anos foram incluídas neste estudo. Os níveis basais de estradiol foram significativamente maiores (p<0,001) após a indução da ovulação do que antes desta. Os resultados dos testes de ruptura do filme lacrimal e após a indução foi de 6,2 ± 2,8 s e 8,4 ± 1,4 s respectivamente. Os valores do teste de Schirmer foram 14,3 ± 7,1 mm e 20,6 ± 6,2 mm, respectivamente antes e depois da indução. Ambos os valores foram significativamente maiores após a indução da ovulação (p<0,001; p=0,001 respectivamente).
Conclusão: Observamos uma melhora nos testes de função lacrimal após o uso de estradiol, mesmo por tempo limitado. O uso de estradiol durante a menopausa poderá melhorar os sintomas do olho seco em pacientes.
Keywords: Estradiol; Síndromes do olho seco; Periodo fertil; Menopausa; Tomografia de coerência óptica
Abstract
MÉTODOS: Córneas humanas de treinamento disponibilizadas foram randomizadas em quatro grupos: Pachy-100 (profundidade de incisão = espessura corneana central - margem de segurança de 100 µm), Pachy-50 (margem de segurança de 50 µm), Pachy-0 (sem margem de segurança) e Pachy+50 (profundidade de incisão = espessura corneana central + 50 µm). Todas as lamelas foram dissecadas através um método padronizado e já publicado (Pachy-DSEK). As espessuras das lamelas (centro, zona de 3,0mm e zona de 6,0mm) foram medidas com tomografia de coerência óptica. A razão de espessura centro-periferia foi calculada aos 3,0 e 6,0 mm de diâmetro.
RESULTADOS: Perfuração endotelial ocorreu apenas no grupo Pachy+50 (n=3, 30%). A espessura central da lamela nos grupos Pachy-100, Pachy-50, Pachy-0 e Pachy+50 foi de 185 ± 42 µm, 122 ± 29 µm, 114 ± 29 µm, e 58 ± 31 µm, respectivamente (p<0,001). As razões C/P aos 3,0 e 6,0 mm foram de 0,97 ± 0,06 e 0,92 ± 0,14, respectivamente. Os parâmetros de características do doador não se correlacionaram com os resultados de espessura de lamela. A profundidade planejada de incisão se correlacionou com a maioria dos parâmetros de espessura de lamela (p<0,001). A espessura de lamela se correlacionou negativamente com a profundidade planejada da incisão (p<0.001, r=-0,580). O melhor resultado foi observado no grupo Pachy-0, em que 75% das lamelas mediram abaixo de 130 µm e não houve perfuração endotelial.
CONCLUSÃO: Através de um método padronizado de dissecção, a maioria das lamelas endoteliais apresentou uma configuração planar. O planejamento de profundidade de incisão igual à espessura corneana central resultou em alta porcentagem de lamelas ultrafinas sem ocorrência de perfuração.
Keywords: Transplante de córnea; Ceratoplastia lamelar; Endotélio corneano; Dissecção; Tomografia de coerência óptica
Abstract
Objetivo: Comparar os parâmetros de câmara anterior obtidos através da tomografia de coerência óptica de segmento anterior antes e após a iridectomia periférica a laser.
Métodos: Quatorze pacientes com fechamento angular primário e seis com glaucoma primário de ângulo fechado foram prospectivamente avaliados neste estudo. Gonioscopia e tomografia de coerência óptica de segmento anterior com DRI OCT Triton®foram realizadas antes e após a iridectomia periférica a laser. Os seguintes parâmetros de tomografia de coerência óptica de segmento anterior, baseados na localização do esporão escleral, foram avaliados: ângulo de abertura angular a 250 µm, 500 µm e 750 µm, área do espaço entre a íris e o trabeculado a 500 µm, ângulo entre a íris e o trabeculado, extensão do contato entre a íris e o trabeculado e curvatura da íris.
Resultados: A tomografia de coerência óptica de segmento anterior identificou 61% dos indivíduos com dois ou mais quadrantes fechados. A gonioscopia identificou mais quadrantes com ângulo fechado do que tomografia de coerência óptica de segmento anterior antes da iridectomia periférica a laser. Quanto aos parâmetros angulares, apenas ângulo de abertura angular a 250 µm no quadrante nasal não aumentou significativamente após a iridectomia
periférica a laser. A curvatura da íris e a extensão do contato entre a íris e o trabeculado apresentaram redução significativa induzida pelo procedimento a laser. Mesmo nos olhos em que a gonioscopia não identificou aumento da amplitude angular após iridectomia periférica a laser (n=7), ângulo de abertura angular a 750 µm aumentou (nasal: 0,15 ± 0,10 mm para 0,27
± 0,16 mm, p=0,01; temporal: 0,14 ± 0,11 mm para 0,25 ± 0,12 mm, p=0,001), e ICURVE diminuiu (nasal: 0,25 ±
0,04 mm vs. 0,11 ± 0,07 mm, p=0,02; temporal: 0,25 ± 0,07 mm vs. 0,14 ± 0,08 mm, p=0,007).
Conclusão: As alterações na câmara anterior induzidas pelo iridectomia periférica a laser puderam ser avaliadas quantitativamente e documentadas pelo DRI OCT Triton®.
Keywords: Gonioscopia; Tomografia de coerência óptica; Segmento anterior do olho; Glaucoma de ângulo fechado; Iridectomia; Terapia a laser; Lasers
Abstract
Objetivo: Comparar as diferenças entre a chord aparente µ e o chord real µ.
Métodos: Estudo prospectivo, comparativo, não randomizado e não intervencionista. Os exames de imagem (Pentacam e HD Analyzer) foram realizados na mesma sala e nas mesmas condições escotópicas. Os critérios de inclusão foram idade de 21 a 71 anos; compreensão do termo de consentimento; miopia até 4D e astigmatismo topográfico anterior até 1D. Os critérios de exclusão foram usuários de lentes de contato; pacientes com doenças oculares prévias ou cirurgias; opacidades da córnea; a presença de alterações tomográficas da córnea ou suspeita de ceratocone.
Resultados: Em nosso estudo foram analisados 116 olhos de 58 pacientes. A média de idade foi de 30,69 anos (± 7,85). Análises de correlação foram desenvolvidas e o coeficiente de correlação de Pearson (0,647) indica uma relação linear positiva moderada entre as variáveis. A média do chord µ real foi 226,21± 128,53 µm e a média do chord µ média foi 278,66 ± 123,90 µm, com diferença média de 52,45 µm (p=0,01).
A análise do diâmetro pupilar médio apresentou: 5,76mm no HD Analyzer e 3,31mm no Pentacam.
Conclusões: Entendemos a existência de uma diferença significativa entre os métodos e assim a medida de ambos os dispositivos com base em princípios diferentes devemos respeitar suas peculiaridades. Como encontramos correlação entre as duas medidas, acreditamos que ambas podem ser utilizadas na prática diária.
Keywords: Imagem óptica; Percepção visual; Pupila; Segmento anterior do olho; Córnea; Técnicas de diagnóstico oftalmológico
Abstract
PURPOSE: This study aimed to evaluate the total macular thickness as well as the thickness of the inner and outer retinal layers in patients with Parkinson's disease. It also aimed to verify the correlation of these parameters with motor symptoms and cognitive function.
METHODS: A total of 46 eyes of 23 patients with Parkinson's disease and 40 eyes of 20 healthy controls were included in the study. The patients' cognitive, functional, and nonmotor symptoms were evaluated using the Katz Index of Independence and Pfeffer's Activities of Daily Living, Mini-Mental State Examination, Frontal Assessment Battery, Schwab and England Staging Scales, and Movement Disorders Society Nonmotor Symptoms Scale. The macular thickness measurements obtained via total, inner, and outer optical coherence tomography were recorded. Furthermore, the correlation of the parameters of optical coherence tomography with cognitive, functional, and nonmotor symptoms was assessed.
RESULTS: The scores of the Katz Index of Independence and Pfeffer's Activities of Daily Living as well as the Movement Disorders Society Nonmotor Symptoms Scale were significantly lower in patients with Parkinson's disease than in healthy controls. Moreover, the former had greater total macular thickness. The temporal and inferior outer sectors were significantly greater for the ganglion cell complex thickness in patients. A significant correlation was observed between the total macular thickness and the Movement Disorder Society-Unified Parkinson's Disease Rating Scale, Parte III (MDS-UPDRS-III) values. Contrarily, there was a negative correlation between the outer macular thickness and the MDS-UPDRS-III values. Meanwhile, the total macular thickness and ganglion cell complex thickness were significantly correlated with the scores of the Mini-Mental State Examination, Schwab and England Staging Scale, Frontal Assessment Battery, and Katz Index of Independence and Pfeffer's Activities of Daily Living. In addition, the Schwab and England scale was correlated with the outer macular thickness.
CONCLUSION: The total and inner macular thicknesses at the temporal and inferior outer sectors were greater in patients with Parkinson's disease than in the control group. These findings indicate that macular thickness may be greater in those with Parkinson's disease, particularly when associated with mild motor symptoms. In addition, the parameters of the total, inner, and outer optical coherence tomography were significantly associated with motor and nonmotor symptoms as well as cognitive function impairment.
Keywords: Parkinson's disease; Tomography, optical coherence; Neurodegenerative diseases; Cognitive dysfunction; Cognition; Motor perception; Visual acuity; Retina
Abstract
PURPOSE: This study aimed to characterize retinitis pigmentosa associated with the eyes shut homolog gene, which causes hereditary retinal degeneration.
METHODS: The anatomical and functional findings of retinitis pigmentosa in patients with variants of the eyes shut homolog gene were characterized and compared using multimodal imaging and genetic analysis of the variants. Clinical data such as visual acuity, lens status, and refraction were obtained from medical records. Patients underwent an ophthalmic examination, including static visual field, microperimetry, optical coherence tomography, fundus autofluorescence, and fundus photography.
RESULTS: Twenty-two patients were included in the study. Several anatomical and functional characteristics of retinitis pigmentosa-eyes shut homolog were identified, including the presence of cataracts, cystoid macular edema, epiretinal membrane, and a tubular visual field. Genetic results revealed 26 distinct variants in the cohort, with 7 novel variants not previously documented or reported in the scientific literature or databases.
CONCLUSION: The findings demonstrate that eyes shut homolog-retinitis pigmentosa manifests in specific patterns, starting in adolescence with mild progression and advancing with age. The integration of multimodal imaging and genetic analysis has provided a detailed understanding of the anatomical and functional features of retinitis pigmentosa-eyes shut homolog. Seven novel variants of the eyes shut homolog gene have been identified. These findings enhance the understanding of eyes shut homolog-related retinitis pigmentosa characteristics of by detailing the spectrum of mutations in this gene within the Brazilian population.
Keywords: Retinal diseases/diagnostic imaging; Retinitis pigmentosa/genetics; Retinal degeneration; Eye proteins/genetics; Eye diseases, hereditary/genetics; Genes, recessive; Phenotype; Multimodal imaging; Tomography, optical coherence/methods; Fluorescein angiogr
Abstract
Objetivos: Este estudo teve como objetivo examinar a superfície ocular de crianças com transtorno de déficit de atenção com hiperatividade e identificar os efeitos adversos do metilfenidato relacionados à síndrome do olho seco.
Métodos: Este estudo transversal incluiu crianças com transtorno de déficit de atenção e hiperatividade e crianças saudáveis (todas entre 5-18 anos de idade). Elas foram randomizadas no Grupo A (sem tratamento com metilfenidato), Grupo B (com tratamento com metilfenidato) e Grupo C (crianças saudáveis). Foram avaliados o tempo de ruptura do filme lacrimal, questionário sobre Índice de Doenças de Superfície Ocular (IDSO), altura do menisco lacrimal, área do menisco lacrimal e os resultados do teste de Schirmer. Além disso, a gravidade dos sintomas no transtorno de déficit de atenção com hiperatividade foi avaliada usando a Turgay DSM-IV-based Child and Adolescent Behavioral Disorders Screening and Rating Scale com base na escala de Conners Parent Rating Scale-48.
Resultados: Os Grupos A, B e C consistiram de 34, 40 e 60 indivíduos (n=34, 40 e 60 olhos; idade=11,44 ± 2,79, 11,70 ± 2,83 e 11,96 ± 3,63 anos, idade média=12, 123 e 11,5 anos), respectivamente. O tempo de ruptura do filme lacrimal, o Índice de Doença da Superfície Ocular, as altura do menisco lacrimal, a área do menisco lacrimal e o teste de Schirmer não foram significativamente diferentes entre os Grupo A e C (p=0,964, 0,336, 0,445, 0,439 e 0,759, respectivamente). Entretanto, o Grupo B mostrou uma redução significativa no tempo de ruptura do filme lacrimal (10,50 ± 3,39 vs 12,52 ± 2,46 seg; p=0,005), altura do menisco lacrimal (307,40 ± 5,53 vs 310,82 ± 7,30 µm; p= 0,025), área do menisco lacrimal (0,024 ± 0,0037 vs 0,026 ± 0,0046 mm2; p=0,010) e teste de Schirmer (12,75 ± 3,96 vs 15,41 ± 3,75 mm; p=0,004), resultados com0arados com o Grupo A.
Conclusão: Em comparação com crianças saudáveis, crianças com transtorno de déficit
de atenção com hiperatividade apresentaram parâmetros de superfície ocular sugestivos de olho seco, apesar do uso de metilfenidato. Assim, elas requerem um acompanhamento oftalmológico próximo para evitar complicações oculares de olho seco que ameaçam a visão.
Keywords: Transtorno do deficit de atenção com hiperatividade; Metilfenidato/efeitos adversos; Segmento anterior do olho; Tomografia de coerência óptica; Síndrome do olho seco
Abstract
PURPOSE: To evaluate the clinical results of cryopreserved amniotic membrane transplantation as a treatment option for refractory neurotrophic corneal ulcers.
METHODS: This prospective study included 11 eyes of 11 patients who underwent amniotic membrane transplantation for the treatment of refractory neurotrophic corneal ulcers at Hospital de Clínicas da Universidade Federal do Paraná, in the city of Curitiba, from May 2015 to July 2021. Patients underwent different surgical techniques in which the amniotic membrane was applied with the epithelium facing upward to promote corneal re-epithelialization.
RESULTS: The median age of the patients was 60 years (range, 34-82 years), and 64% were men. The predominant etiology of corneal ulcers was herpes zoster (45% of cases). Approximately one-third of the patients (27%) were chronically using hypotensive eye drops, and more than half (54%) had previously undergone penetrating corneal transplantation. At the time of amniotic membrane transplantation, 18% of the eyes had corneal melting, 9% had corneal perforation, and the others had corneal ulceration without other associated complications (73%). The time between clinical diagnosis and surgical treatment ranged from 9 days to 2 years. The corrected visual acuity was worse than 20/400 in 90% of the patients preoperatively, with improvement in 36% after 3 months of the procedure, worsening in 18% and remaining stable in 36%. Of the patients, 81% complained of preoperative pain, and 66% of them reported total symptom relief after the surgical procedure. In one month, 54.6% of the patients presented a closure of epithelial defect, and half of the total group evolved with corneal thinning. The failure rate was 45.5% of the cases.
CONCLUSION: Cryopreserved amniotic membrane transplantation can be considered a good alternative for treating refractory neurotrophic corneal ulcers, as it resulted in significant improvement in pain (66%) and complete epithelial closure (60%) in many patients at 1 month postoperatively. Notably, the high failure rate highlights the need for further studies to identify patient- and ulcer-related factors that may influence the outcomes of this procedure.
Keywords: Amnion/transplantation; Corneal ulcer; Anterior eye segment; Keratitis
Abstract
O coloboma ocular é o resultado de um fechamento impróprio da fissura embrionária. As drusas da cabeça do nervo óptico são depósitos hialinos localizados anteriormente à lâmina cribosa que crescem e se calcificam com o tempo. A associação de ambos é rara, com apenas dois casos descritos na literatura. Apresentamos um paciente com coloboma irido-coriorretiniano e limites do nervo óptico mal definidos em seu olho direito, e aumento da ramificação vascular papilar e atrofia peripapilar em seu olho esquerdo, sem drusas visíveis. Autofluorescência de fundo, tomografia de coerência óptica de alta resolução e ultrassonografia B-scan foram realizadas confirmando o diagnóstico de drusas enterradas bilaterais da cabeça do nervo óptico. A associação entre colobomas irido-coriorretinianos com drusas do nervo óptico na ausência de doença sistêmica é excepcional. Nosso caso demonstra a importância da imagem multimodal para o diagnóstico correto de drusas enterradas de cabeça do nervo óptico.
Keywords: Coloboma; Retina/anormalidade; Doença do nervo óptico; Drusas do disco óptico; Tomografia de coerência óptica; Acuidade visual; Humano; Relato de caso
Abstract
Paciente do sexo feminino, 42 anos, com perda visual e epífora crônica no olho esquerdo. Sua acuidade visual melhor corrigida foi de 10/10 no olho direito e 0,3/10 no olho esquerdo. O exame do segmento anterior foi normal. No exame de fundo de olho, foram detectadas pregas coroidais. A tomografia de coerência óptica revelou elevação na mácula e pregas coroidais. A ultrassonografia revelou sinal T. A imagem de ressonância magnética mostrou mucocele etmoidal que comprime os tecidos orbitários. O Departamento de Otorrinolaringologia realizou o tratamento cirúrgico. No pós-operatório, as dobras coroidais se recuperaram, a acuidade visual melhor corrigida foi melhorada, mas ocorreu líquido sub-retiniano. Durante o período de acompanhamento sem qualquer tratamento, o líquido sub-retiniano recuperou-se totalmente.
Keywords: Maculopatia; Tomografia de coerência óptica; Doenças da coroide; Mucocele
Abstract
Uma mulher de 71 anos de idade apresentou neuropatia óptica isquêmica anterior não arterítica no nervo óptico com fibras nervosas peripapilares mielinizadas previamente registradas. Seu histórico médico foi significativo para hipertensão arterial sistêmica controlada, hiperlipidemia e diabetes mellitus. Em ambos os discos ópticos, a tacícula fisiológica esteve ausente. A neuropatia óptica isquêmica anterior não arterítica afetou principalmente os setores temporal e inferior da camada de fibras nervosas da retina peripapilar, como demonstrado pela tomografia de coerência óptica da camada de fibras nervosas da retina e pela angiotomografia de coerência óptica do disco óptico. Ao contrário de outros relatórios publicados, apenas uma ligeira regressão das fibras nervosas mielinizadas foi observada após um ano de acompanhamento. Isto pode ser explicado pelo fato da isquemia ter afetado principalmente os setores temporal e inferior peripapilares, enquanto as fibras nervosas de mielina eram nasal superior ao disco óptico.
Keywords: Neuropatia óptica isquêmica; Fibras nervosas mielinizadas; Doenças do nervo óptico; Tomografia de coerência óptica; Neovascularização retiniana; Acuidade visual; Humanos; Relato de casos
Abstract
Em decorrência de complicações, da biocompatibilidade e da escassez de tecido doador para transplantes de córnea natural, foram elaboradas córneas artificiais que são potenciais para reabilitar funções ópticas. Nessa perspectiva, objetivou-se a análise da eficácia da reabilitação visual entre os implantes: Boston tipo I, Boston tipo II, Aurolab, osteo-odonto-ceratoprótese e ceratoprótese de Osso Tibial. De modo geral, a princípio observou-se uma tendência de melhoria da Best-corrected visual acuity em todos os tipos de lentes, mas considerável queda durante acompanhamento a longo prazo. O dispositivo com melhor reabilitação visual em pacientes com superfícies oculares úmidas é a Boston tipo I, seguida pela Aurolab, que é economicamente viável em países emergentes. Ao considerar pacientes com olhos secos, o implante de Boston tipo II apresenta maior reabilitação visual. Por fim, em virtude de não apresentarem dados equiparáveis, as lentes osteo-odonto-ceratoprótese e de osso tibial não puderam ser analisadas.
Keywords: Transplante de córnea; Próteses visuais; Córnea; Reabilitação; Acuidade visual
ABO is licensed under a Creative Commons Attribution-NonComercial 4.0 Internacional.
About
Issues
Editorial Board
Submission
Official publication of Conselho Brasileiro de Oftalmologia
Rua Casa do Ator, 1.117 - 2º andar - CEP: 04546-004
São Paulo - SP, Brazil
Phone: +55 11 3266-4000