Showing of 1 until 15 from 78 result(s)
Search for: Macular degeneration/prevention & control; Dietary supplements; Vitamins/ administration & dosage; Lutein/administration & dosage; Guideline as topic/ standards; Turkey
Abstract
OBJETIVOS: Comparar as taxas de sucesso anatômico da vitrectomia e tamponamento de gás SF6 na cirurgia de buraco macular com e sem a postura pronada pós-operatória.
MÉTODOS: Foi realizado um estudo observacional, longitudinal e retrospectivo de séries de casos. O estudo incluiu 52 olhos de 52 pacientes submetidos à vitrectomia posterior via pars-plana com peeling de membrana limitante interna auxiliada por azul trypan e tamponamento com gás SF6 a 25% para os estágios 2, 3 e 4 dos buracos maculares. Após a cirurgia, todos os pacientes foram orientados a manter um regime postural pós-operatório: 31 pacientes foram orientados a não realizar posição pronada de cabeça, enquanto 21 foram orientados a manter uma pronada pós-operatória por 7 dias. O objetivo principal foi a análise da taxa de fechamento do buraco macular. A análise estatística foi realizada usando Epi-Info 7.1.
RESULTADOS: Um total de 47 (90,3%) pacientes obtiveram fechamento do buraco macular. O grupo de postura não pronada e o grupo de postura pronada obtiveram taxas de fechamento de 90,3%, e 90,4%, respectivamente; essas taxas não foram significativamente diferentes. A análise estatística revelou que não houve diferenças significativas relacionadas ao gênero, idade, duração do buraco macular, estágio do buraco macular, acuidade visual corrigida pré e pós-operatória entre os dois grupos.
CONCLUSÃO: Nossos resultados sugerem que a cirurgia para buraco macular com o uso de gás de curta duração (SF6) é segura e eficaz e que a manutenção de uma orientação pós-operatória de não-pronada também é segura. No entanto, essas recomendações devem ser avaliadas em um estudo prospectivo e randomizado para delinear de forma abrangente os riscos e benefícios associados.
Keywords: Perfurações retinianas; Vitrectomia; Cirurgia vitreorretiniana; Hexafluoreto de enxofre/administração & dosagem; Fluorocarbonetos/administração & dosagem; Decúbito dorsal; Cuidados pós-operatórios
Abstract
OBJETIVO: Analisar o perfil e a taxa de publicação em periódicos indexados de resumos apresentados na seção de córnea da reunião anual da Association for Research in Vision and Ophthalmology - ARVO, para identificar potenciais fatores preditivos com objetivo de obter melhores resultados.
MÉTODOS: Artigos que foram aceitos para apresentação no encontro anual da Association for Research in Vision and Ophthalmology - ARVO 2013 na seção de córnea foram pesquisados via PubMed e Scopus para identificar se haviam sido publicados como manuscritos com texto integral. Nome do primeiro autor, data de publicação, nome da revista e fator de impacto foram registrados. Foi feita uma regressão multivariada para estabelecer uma associação entre as variáveis e a chance de publicação e o fator de impacto da revista. Foi utilizado o método Kaplan-Meier para analisar o tempo da apresentação até a publicação dos artigos.
RESULTADOS: Dos 939 artigos analisados, 360 (38.3%) foram publicados em revistas com um fator de impacto médio de 3.4. O intervalo de tempo entre a submissão do resumo e a publicação do artigo teve como mediana 22 meses. Na análise multivariada, resumos tinham mais chance de publicação se tinham algum tipo de financiamento (OR=1.482, p=0.005), tinham grupo controle (OR=1.511, p=0.016) e estavam no âmbito da pesquisa científica básica (OR+1.388, p=0.020). O fator de impacto da revista era maior em estudos financiados (β=0.163, p=0.002) e mais baixo naqueles multicêntricos (β=-0.170, p=0.001). A análise Kaplan-Meier mostrou diferenças significativas na distribuição de tempo até a publicação de resumos de ciência básica vs clínicos (χ2=7.636), com grupo controle vs sem grupo controle (χ2=6.921) e financiados vs não financiados (χ2=13.892) (p<0.05).
CONCLUSÃO: Aproximadamente 40% dos resumos apresentados no encontro da Association for Research in Vision and Ophthalmology - ARVO foram publicados dentro de 5 anos da submissão. Financiamento, pesquisa no âmbito da ciência básica e presença de grupo controle foram fatores determinantes para melhores resultados em relação à chance de publicação.
Keywords: Resumos e indexação como assunto; Bibliometria; Congressos como assunto; Resumo de reunião; Publicações/estatística & dados numéricos; Córnea
Abstract
Objetivo: O trauma ocular é uma causa importante e amplamente evitável de cegueira em todo o mundo. Nosso objetivo é estudar suas características nos EUA.
Métodos: Revisão retrospectiva do National Trauma Data Bank (2008-2014). Todos os pacientes com trauma ocular foram identificados com códigos CID-9CM. Os dados coletados foram analisados estatísticamente e o teste t de student foi utilizado. As análises qui-quadrado e de regressão logística foram realizadas com o software SPSS. A significância foi estabelecida em p<0,05.
Resultados: 316.485 (5,93%) de 5.336.575 pacientes internados com trauma, apresentaram lesões oculares. A média (DP) de idade foi de 41,8 (23) anos. A maioria era do sexo masculino (69,4%). A distribuição raça/etnia foi branca: 66,1%, negra; 15,1% e hispânica: 12,3%. As lesões comuns foram orbitárias: 39,5% e contusões dos olhos/anexos: 34%. A maioria (58,2%) teve lesão cerebral traumática. Os mecanismos frequentes foram: quedas: 25,5%, acidente com veículos motorizados: 21,8% e acidentes atingidos por algo/contra algo: 17,6%. Os pacientes <21 anos apresentaram chance aumentada de lesões com corte/perfuração (RC=3,29; IC95% = 3,07-3,51) do que outras faixas etárias, aqueles entre 21-64 anos responderam por acidente automobilístico-ciclista: (RC=4,95; IC95% = 4,71-5,19) e aqueles >65 anos foram vítimas de quedas (RC=16,75; IC 95% = 16,39-17,12); p<0,001. Os negros apresentaram maior probabilidade de lesões por arma de fogo (RC=3,24; IC95% = 3,10-3,39) do que outras raças/etnias e os hispânicos tiveram mais lesões de corte/perfuração (RC=2,01; IC95%= 1,85-2,18) enquanto os brancos tiveram mais quedas: (RC=2,3; IC95%= 2,3-2,4); p<0,001. Os negros (RC=3,41; IC95% = 3,34-3,48) e os hispânicos (RC=1,75; IC95% = 1,71-1,79) sofreram principalmente agressões e os brancos tiveram lesões não intencionais (RC=2,78; IC95% 2,74-2,84); p<0,001. Lesões do nervo óptico/via visual apresentaram maior associação com escore de gravidade de lesão muito grave (RC=3,27; IC95%= 3,05-3,49) e escores graves de Coma de Glasgow (RC=3,30; IC95%= 3,08-3,54); p<0,001. A taxa de mortalidade foi de 3,9%.
Conclusões: Houve preponderância masculina a quedas, a acidentes com veículo motorizado atingidos por algo/contra algo conforme os relatos anteriores. Os padrões demográficos identificados realçam a necessidade de desenvolver medidas de prevenção específicas para os diferentes grupos.
Keywords: Traumatismo ocular; Cegueira/prevenção & controle; Estados Unidos/epidemiologia
Abstract
Introdução: Os oftalmologistas têm alto risco de contrair a doença do Coronavírus-19 devido à proximidade com os pacientes durante os exames com lâmpada de fenda. Usamos um modelo de computação para avaliar a eficácia das proteções para lâmpadas de fenda e propusemos uma nova proteção ergonomicamente projetada.
Métodos: As simulações foram realizadas no software comercial Star-CCM +. Os aerossóis de gotículas foram considerados 100% de água em fração de volume com distribuição de diâmetro de partícula representada por uma média geométrica de 74,4 ± 1,5 (desvio padrão) μm ao longo de uma duração de quatro minutos. A massa total de gotículas de água acumulada no manequim e a massa expelida pela boca do paciente foram medidas em três condições diferentes: 1) Sem protetor de lâmpada de fenda, 2) com protetor padrão, 3) Com o novo protetor proposto.
Resultados: A massa total acumulada das gotas de água (kg) e a porcentagem da massa expelida acumulada no escudo para cada uma das respectivas condições foram; 1) 5,84e-10 kg (28% do peso total da partícula emitida que assentou no manequim), 2) 9,14e-13 kg (0,045%), 3,19e-13 (0,015%). O escudo padrão foi capaz de proteger 99,83% das partículas que, de outra forma, teriam se depositado no manequim, o que é semelhante a 99,95% para o projeto proposto.
Conclusão: Protetores com lâmpada de fenda são ferramentas eficazes de controle de infecção contra gotículas respiratórias. O protetor proposto mostrou eficácia comparável em comparação com os protetores de lâmpada de fenda convencionais, mas potencialmente oferece uma melhor ergonomia para oftalmologistas durante o exame de lâmpada de fenda.
Keywords: Oftalmologistas; Infeções por coronavírus/prevenção & controle; Pandemias; Gotículas lipídicas; SARS-CoV-2; Lâmpada de fenda; Simulação por computador; Equipamentos de proteção; Desenho de equipamento.
Abstract
Objetivo: Comparar a eficácia de três injeções intravítreas mensais iniciais de aflibercept, seguidas de dosagem de pro re nata (3+PRN) versus cinco injeções mensais iniciais intravítreas de aflibercept, seguidas de doses de pro re nata (5+PRN) em pacientes com edema macular diabético.
Métodos: Foram analisados neste estudo retrospectivo e comparativo 60 pacientes que não receberam tratamento prévio com edema macular e foram submetidos a injeções intravítreas de aflibercept (2 mg/0,05 mL) com pelo menos um ano de acompanhamento. Os pacientes foram divididos em dois grupos de acordo com o número de injeções intravítreas de aflibercept administradas na fase inicial. O grupo 3+PRN compreendeu 27 pacientes, enquanto o grupo 5+PRN compreendeu 33 pacientes. Os resultados visuais e anatômicos foram comparados entre os dois grupos no período inicial e aos 3, 6, 9 e 12 meses.
Resultados: Tanto os grupos 3+PRN quanto 5+PRN mostraram melhoras estatisticamente significativas na acuidade visual melhor corrigida e na espessura macular central ao longo do período de estudo (p<0,001 e p <0,001, respectivamente). Não houve diferenças significativas entre os dois grupos em termos de alterações na acuidade visual melhor corrigida e na espessura macular central (p=0,453 e p=0,784, respectivamente). O número médio de injeções intravítreas de aflibercept foi significativamente maior no grupo 5+PRN (6,1 ± 0,8) do que no grupo 3+PRN (3,9 ± 0,8) (p <0,001).
Conclusão: Os regimes 3+PRN e 5+PRN mostraram resultados visuais e anatômicos semelhantes em 12 meses após o tratamento com injeções intravítreas de aflibercept em pacientes com edema macular.
Keywords: Retinopatia diabética; Edema macular; Injeções intravítreas; Receptores de fatores de crescimento do endotélio vascular/administração & dosagem
Abstract
Objetivo: Descrever os resultados anatômicos e visuais associados à injeção intravítrea de perfluoropropano seguida de tratamento a laser para descolamento de retina macular secundário à fosseta do disco óptico.
Métodos: Estudo retrospectivo em um único centro. Foram revisados os prontuários médicos dos pacientes com descolamento macular associado a fosseta do disco óptico congênito em um centro de referência terciário de retina entre 2011 e 2018. Todos receberam como estratégia de tratamento inicial injeção intravítrea de perfluoropropano 100% seguido por fotocoagulação a laser ao longo da margem temporal do disco óptico.
Resultados: Foram identificados seis pacientes com descolamento macular associado a fosseta do disco óptico durante o período do estudo. O seguimento pós-operatório variou de 13 a 52 meses, com média de 28 meses. SD-OCT demonstrou resolução completa do fluido em cindo dos seis casos, sem recorrência. Quatro casos apresentaram reabsorção completa após perfluoropropano intravítreo associado a laser, e um paciente necessitou de procedimento adicional (vitrectomia via pars plana com peeling da membrana limitante interna e inversão do retalho do pedículo sobre a margem temporal do disco óptico) para obter reabsorção completa de fluidos. Um paciente apresentou fluido intrarretiniano persistente e negou tratamentos adicionais. O tempo entre o procedimento inicial e a resolução completa do fluido variou entre 6,5 a 41 meses, com média de 19,5 meses. A acuidade visual corrigida melhorou após a cirurgia, considerando a última consulta de acompanhamento em todos os casos.
Conclusão: A injeção intravítrea de perfluoropropano 100% seguida de fotocoagulação ao longo da margem temporal da margem do disco óptico foi associada à melhora anatômica e visual na maioria dos casos e representa uma abordagem terapêutica alternativa para o descolamento macular associado a fosseta do disco óptico.
Keywords: Disco óptico/anormalidades; Doenças do nervo óptico/complicações; Descolamento retiniano; Terapia a laser; Injeções intravítreas; Fluorcarbonetos/administração & dosagem; Gases/administração & dosagem.
Abstract
PURPOSE: To assess female participation in the Brazilian Congress of Ophthalmology.
METHODS: This retrospective, descriptive-analytical study examined the profiles of individuals involved in the scientific program of the Brazilian Congress of Ophthalmology from 2016 to 2023. Data were provided by the Brazilian Council of Ophthalmology and were categorized by ophthalmology subspecialty, participant role, and geographic region of origin within Brazil. Roles were grouped into three main categories: coordinator, speaker, and moderator/discussant.
RESULTS: Female participation at the congress increased from 33% in 2016 to 42% in 2023, showing an annual upward trend of 1.33 (p<0.001). Around 64% of female participants were from the Southeast region, while 16% were from the Northeast. The coordinator role showed the largest increase in female participation, rising from 22% in 2016 to 40% in 2023 (Slope: 2; p<0.001), followed by the speaker role, which increased from 34% to 44% (Slope: 1.5; p<0.001), and the moderator/discussant role, which rose from 32% to 38% (Slope: 1.24; p=0.0586). Changes in female representation across ophthalmology subspecialties were not statistically significant.
CONCLUSION: From 2016–2023, female participation in the Brazilian Congress of Ophthalmology increased across most subspecialties and conference roles. Although gender disparity has narrowed, continuous efforts are needed to achieve greater gender equity and equality in ophthalmology conferences.
Keywords: Ophthalmology; Gender equity; Ophthalmologists/statistics & numerical data; Physicians, women/statistics & numerical data; Leadership; Congresses as topic/statistics & numerical data.
Abstract
Purpose: To analyze the clinical outcomes of the ocular surface in patients with vitamin D deficiency after oral replacement.
Methods: A total of 40 patients with vitamin D deficiency were enrolled in the study. The patients received 50,000 units of oral vitamin D weekly over a period of 8 weeks. After 8 weeks, 1,500-2,000 units/d were administered for 24 weeks. Eyelid margin score, meibomian gland expressibility score, Oxford grading, Schirmer I test, tear breakup time, tear osmolarity, and the Ocular Surface Disease Index score were evaluated at baseline, and at 8, 12, and 24 weeks.
Results: The meibomian gland expressibility score, Schirmer I, tear breakup time, tear osmolarity, and Ocular Surface Disease Index score showed improvement 8 weeks after vitamin D supplementation (p<0.05). Compared with the pretreatment values, the eyelid margin score and Oxford grading were decreased at week 12 (p<0.05).
Conclusion: Vitamin D replacement appears to improve ocular surface in individuals with vitamin D deficiency.
Keywords: Dry eye syndrome; Vitamin D deficiency; Dietary supplements
Abstract
Objetivo: Determinar o impacto do uso de unidade móvel no acesso à saúde ocular e avaliar o perfil da população que necessita de cuidados oftalmológicos, as doenças oculares mais frequentes e o tratamento. Métodos: Estudo transversal realizado em 14 municípios da região sudoeste do Estado de São Paulo utilizando uma unidade móvel oftalmológica. Os participantes eram usuários do Sistema Único de Saúde que procuraram atendimento oftalmológico, sem restrição quanto a idade, gênero ou condição socioeconômica. Os dados foram transferidos para a tabela Excel para análise estatística. Resultados: Participaram do estudo 6.878 pessoas, com média de idade de 44 anos (variação de 4 meses a 96 anos) e 65,5% eram mulheres. Erros refrativos estavam presentes em 78,6% dos participantes, catarata em 9,6% e pterígio em 8,3%. Para 60% foram prescritos óculos, para 10% foi mantida a correção óptica em uso e para 28% foram necessárias apenas orientações. Exames especializados ou procedimentos cirúrgicos foram indicados para 18,1% dos casos que foram encaminhados para tratamento em serviço terciário. Dentre os pacientes referenciados, 36,4% necessitavam de cirurgia oculoplástica ou para tratar afecções externas do olho e 31,8%, de cirurgia de catarata. Conclusão: A grande maioria dos pacientes que procurou atendimento na unidade móvel necessitava de prescrição de óculos. A unidade móvel oftalmológica possui alto grau de resolutividade para os problemas oculares, com oportunidade de tratar os erros refrativos e referenciar os pacientes que necessitam de atendimento especializado, geralmente relacionado a condições cirúrgicas. Unidades móveis podem ser uma alternativa aos cuidados oftalmológicos básicos, melhorando o acesso, atuando na promoção da saúde ocular e prevenindo a cegueira.
Keywords: Unidades móveis de saúde; Saúde ocular; Transtornos da visão; Erros de refração; Óculos; Cegueira/prevenção & controle
Abstract
Objetivo: Este estudo de qualidade e confiabilidade teve como objetivo identificar a variabilidade da massa do volume da gota de colírios multidose e verificar a existência de um padrão de referência para o volume da gota dos colírios usando lágrimas artificiais do mercado brasileiro.
Métodos: Cinco marcas de colírios lubrificantes foram avaliadas quanto ao volume da gota. Uma gota padrão ideal de 20 μL de cada fabricante foi coletada usando uma micropipeta ajustável. Os frascos dos colírios foram selecionados aleatoriamente e cinco medidas das massas das amostras foram coletadas usando escalas de precisão calibradas.
Resultados: A massa das amostras de 20 μL variou significativamente (p<0,001) entre os diferentes fabricantes. No entanto, entre os colírios da mesma marca, a variação da massa não foi estatisticamente diferente. A massa média global de todas as gotas pesadas foi de 18,24 mg e foi observada uma não-uniformidade entre todas as marcas de colírios.
Conclusão: Identificou-se uma variação significativa nas massas do volume das gotas dos colírios lubrificantes, usando equipamento padrão de laboratório. A heterogeneidade no volume da gota dos colírios testados sugere a existência de discrepâncias potenciais em suas posologias, possivelmente alterando a eficácia do tratamento. Uma medida de referência pré-estabelecida pode levar à produção de colírios com gotas de tamanho mais apropriado para uso em olhos humanos.
Keywords: Soluções oftálmicas/administração & dosagem; Volume da gota; Padrão de referência dos colírios; Padronização de colírios multidose; Administração de medicamentos oftálmicos; Qualidade
Abstract
Objetivo: Avaliar a eficácia da combinação de injeções intravítreas de bevacizumabe em olhos com edema macular secundário à oclusão de ramo e da veia central da retina após um único implante de dexametasona.
Métodos: Foi realizado um estudo prospectivo intervencionista não comparativo com 44 olhos de pacientes com edema macular relacionado à oclusão de ramo e veia central da retina, sem tratamento prévio e tratados com um único implante de dexametasona, que foram acompanhados em intervalos de quatro semanas do segundo ao sexto mês. Se fosse constatado edema macular persistente ou recorrente durante esse período, os pacientes eram tratados com injeções intravítreas de bevacizumabe em um regime ajustado conforme a necessidade. Foram estudadas a melhor acuidade visual corrigida e alterações da espessura macular central.
Resultados: A média da melhor acuidade visual corrigida mudou de 0,97 ± 0,33 LogMAR iniciais para 0,54 ± 0,40 no exame de 6 meses (p<0,00001). Vinte olhos (45,54%) melhoraram 3 linhas de Snellen ou mais. A média da espessura macular central inicial foi de 670,25 ± 209,9 μm e diminuiu para 317,43 ± 112,68 μm na visita de 6 meses (p<0,00001). O número médio de injeções intravítreas de bevacizumabe em 6 meses foi de 2,32 e o tempo médio entre o implante de dexametasona e a primeira injeção de anti-VEGF foi de 3,45 meses.
Conclusão: Injeções intravítreas de bevacizumabe após um único implante de dexametasona podem proporcionar um aumento da melhor acuidade visual corrigida e diminuição da espessura macular central aos 6 meses em pacientes com edema macular devido à oclusão de ramo e da veia central da retina, com poucas injeções intravítreas.
Keywords: Oclusão da veia retiniana/complicações; Edema macular/tratamento farmacológico; Inibidores de angiogênese/uso terapêutico; Dexametasona/administração & dosagem; Injeções intravítreas; Bevacizumab; Tomografia de coerência óptica; Acuidade visual.
Abstract
The advantages and disadvantages of using perioperative subconjunctival steroid injections in dropless cataract surgery continue to be debated. A systematic review of PubMed, EMBASE, and the Cochrane Central database identified five studies—two randomized controlled trials and three non-randomized studies—encompassing 70,751 eyes. Among these, 12,319 eyes (17.4%) received subconjunctival steroid injections, while 58,432 eyes (82.6%) were managed with topical steroids. The Cochrane Collaboration’s RoB 2 tool was applied for bias assessments in randomized controlled trials, and heterogeneity was assessed using the I² statistics. No statistically significant differences were found between the two groups regarding macular edema (p=0.249), visual acuity (p=0.73), or laser flare count (p=0.45). Both subconjunctival injections and topical steroids demonstrated comparable efficacy and safety in controlling postoperative inflammation after cataract surgery. Additional research is warranted to validate these conclusions.
Keywords: Cataract extraction; Phacoemulsification; Lens implantation, intraocular; Postoperative care; Intravitreal injections; Anti-inflammatory agents, non-steroidal/administration & dosage; Glucocorticoids; Triamcinolone acetonide; Research design; Randomiz
Abstract
PURPOSE: To compare the outcomes of intravitreal dexamethasone implant used as either an adjuvant or a switching therapy for diabetic macular edema in patients with poor anatomic response after three consecutive monthly injections of ranibizumab.
METHODS: This retrospective study included patients with diabetic macular edema who received three consecutive doses of ranibizumab as initial therapy and demonstrated poor response. A single dose of intravitreal dexamethasone implant was administered to these patients. The patients were divided into two groups according to the treatment modalities: the adjuvant therapy group, consisting of patients who continued treatment with ranibizumab injection after receiving intravitreal dexamethasone implant, and the switch therapy group, consisting of patients who were switched from ranibizumab treatment to intravitreal dexamethasone implant as needed. The main outcome measurements were best corrected visual acuity and central retinal thickness at baseline and at 3, 6, 9, and 12 months of follow-up.
RESULTS: In this study that included 64 eyes of 64 patients, the best corrected visual acuity and central retinal thickness values did not significantly differ between the groups at baseline and at 6 months of follow-up (p>0.05). However, at 12 months, the best corrected visual acuity values in the adjuvant and switch therapy groups were 0.46 and 0.35 LogMAR, respectively (p=0.012), and the central retinal thickness values were 344.8 and 270.9, respectively (p=0.007).
CONCLUSIONS: In a real-world setting, it seems more reasonable to use intravitreal dexamethasone implant as a switch therapy rather than an adjuvant therapy for diabetic macula edema refractory to ranibizumab despite three consecutive monthly injections of ranibizumab. Patients switched to intravitreal dexamethasone implant were found to have better anatomic and visual outcomes at 12 months than those who continued ranibizumab therapy despite their less-than-optimal responses.
Keywords: Diabetic retinopathy; Macular edema/drug therapy; Dexamethasone/administration & dosage; Drug implants; Intravitreal injections; Ranibizumab/administration & dosage; Tomography, optical coherence; Endothelial growth factors
Abstract
PURPOSE: To compare the injection of small amounts of undiluted C3F8 with the traditional gas injection in vitrectomy for macular hole treatment.
METHODS: This clinical trial included 26 individuals divided into two groups. Group 1 received an intravitreal injection of 0.9-1.0 mL of 100% C3F8, and Group 2 received 15-20 mL of 20% C3F8.
RESULTS: The median intraocular gas duration was 31 days in Group 1 and 34 in Group 2. The median letter gains in corrected distance visual acuity for the 26th postoperative week were 20 letters in Group 1 and 12.5 in Group 2. The median intraocular pressure was normal in both groups. Primary anatomical success was 11/13 in both groups.
CONCLUSIONS: The use of C3F8 gas in a small undiluted volume is an alternative that slightly reduces the duration of the gas without negatively affecting the anatomical and visual response.
Keywords: Retinal perforations/surgery; Vitrectomy; Sulfur hexafluoride/administration & dosage; Fluorocarbons/administration & dosage; Gases; Tomography, optical coherence
Abstract
A patient presented with corneoscleral thinning five months after the treatment of suspected ocular squamous surface neoplasia with mitomycin-C and interferon. For tectonic and aesthetic purposes, we decided to perform lamellar corneoscleral transplantation. The approach used established new tectonic support and corneal homeostasis. This technique might be an option in similar cases.
Keywords: Corneal diseases/diagnosis; Carcinoma, squamous cell; Conjunctival neoplasms/surgery; Interferon-alpha/therapeutic use; Mitomycin/therapeutic use; Ophthalmic solutions/administration & dosage; Humans; Case reports
ABO is licensed under a Creative Commons Attribution-NonComercial 4.0 Internacional.
About
Issues
Editorial Board
Submission
Official publication of Conselho Brasileiro de Oftalmologia
Rua Casa do Ator, 1.117 - 2º andar - CEP: 04546-004
São Paulo - SP, Brazil
Phone: +55 11 3266-4000