Showing of 1 until 15 from 236 result(s)
Search for: Lacrimal apparatus; Orbital neoplasm; Adenoma; Eye neoplasms; Lacrimal apparatus diseases; Carcinoma, adenoid cystic; Carcinoma, mucoepidermoid; Follow-up studies
Abstract
Objetivo: O objetivo deste estudo é determinar se o tamanho inicial do tumor se correlaciona com o tempo de regressão após terapia tópica com interferon alfa- 2b (1 milhão de UI/ml) no tratamento da neoplasia escamosa da superfície ocular.
Métodos: Foi realizado um estudo retrospectivo em 15 doentes clinicamente diagnosticados com neoplasia escamosa da superfície ocular e tratados com interferon tópico alfa- 2b (1 milhão de UI/ml, quatro vezes ao dia). Todos os casos de neoplasia escamosa da superfície ocular incluídos no estudo apresentaram envolvimento da córnea e do limbo. A extensão inicial da neoplasia escamosa da superfície ocular foi medida em milímetros quadrados usando o programa ImageJ (LOCI, University of Wisconsin, Madison, EUA) em imagens feitas dos olhos de cada paciente imediatamente antes do início do tratamento. O tempo até a resolução do tumor foi observado em cada caso.
Resultados: A resolução tumoral completa foi alcançada em todos os casos, com média da extensão inicial de 26,71 mm2 (desvio padrão ± 17,21 mm2) e tempo médio até a resolução de 77 dias (desvio padrão ± 32 dias). Um aumento do volume tumoral após 15 dias de tratamento foi observado em 2 pacientes com resolução completa do tumor. Não houve correlação significativa entre o tempo até a resolução e a extensão inicial do tumor medida em milímetros quadrados (teste de Spearman, p=0,347).
Conclusões Nosso estudo sugere que a duração do tratamento necessário com interferon alfa- 2b tópico não depende do tamanho inicial do tumor de neoplasia escamosa da superfície ocular geralmente encontrada na prática clínica.
Keywords: Neoplasia da túnica conjuntiva; Doença da córnea/tratamento farmacológico; Carcinoma de célula escamosa; Interferon alfa-2/ uso terapêutico
Abstract
OBJETIVOS: Identificar vasos linfáticos em espécimes orbitários de cadáveres humanos através de microscopia óptica e análise imunohistoquímica.
MÉTODOS: Um estudo postmortem incluiu dez espécimes orbitários provenientes de dez cadáveres humanos. Todos os espécimes orbitários foram obtidos até 12 horas após a morte com uma técnica cirúrgica de exenteração orbitária e dissecados em glândula lacrimal, nervo óptico, gordura órbitária e músculos extraoculares. Para classificar como um vaso linfático, os critérios histológicos incluíram vasos endoteliais de parede única sem membrana basal bem desenvolvida, irregulares e lúmen sem hemácias, e os critérios imunohistoquímicos incluíram vasos endoteliais de parede única, com formato irregular e lúmen sem hemácias e reagentes a podoplanina D2-40.
RESULTADOS: As lâminas histológicas de glândula lacrimal, nervo óptico, tecido adiposo e músculos extraoculares reagiram positivamente a podoplanina D2-40.
CONCLUSÃO: Este estudo demonstrou vasos linfáticos na órbita humana, mais exatamente, na glândula lacrimal, no nervo óptico, na gordura orbitária e nos músculos extrínsecos extraoculares via microscopia óptica e imunohistoquímica.
Keywords: Vasos linfáticos; Órbita; Nervo óptico; Aparelho lacrimal; Músculos oculomotores; Tecido adiposo; Microscopia
Abstract
Objetivo: Uma das desvantagens mais importantes do uso de stents Mini Monoka no reparo de lacerações canaliculares pediátricas é a perda prematura do stent. Neste estudo, objetivamos comparar os resultados clínicos dos stents monocanaliculares Mini Monoka e Masterka em crianças e discutir as possíveis causas da perda prematura do stent.
Métodos: Foram incluídos nesta revisão retrospectiva 36 pacientes <18 anos de idade que se submeteram ao reparo cirúrgico de uma laceração canalicular com um stent Mini Monoka ou Masterka e tiveram pelo menos 6 meses de acompanhamento após a remoção do stent. Foram analisados os dados demográficos, o mecanismo da lesão, o tipo de stent utilizado, a ocorrência de perda prematura de stent e o sucesso da intervenção. O sucesso foi definido como a ausência de epífora após a remoção do stent, sem a perda prematura deste.
Resultados: Vinte e sete pacientes preencheram os critérios do presente estudo e foram incluídos nas análises. O stent Mini Monoka foi usado em 14 pacientes (51,9%), enquanto o Masterka foi usado em 13 pacientes (48,1%). As características clínicas pré-operatórias, incluindo idade, sexo e mecanismo de lesão, foram semelhantes entre os dois grupos. A média de idade foi de 8,3 ± 5,5 anos no grupo Mini Monoka e de 7,8 ± 5,9 anos no grupo Masterka (p=0,61). Três pacientes do grupo Mini-Monoka (21,4%) tiveram que ser operados novamente por perda prematura do stent. Nenhuma perda prematura do stent foi observada no grupo Masterka. Como resultado, a taxa de sucesso foi de 78,6% no grupo Mini Monoka e de 100% no grupo Masterka (p=0,22).
Conclusões: Embora nenhuma diferença estatisticamente significativa tenha sido detectada entre os dois grupos em termos de taxas de sucesso, não observamos nenhuma perda prematura de stent no grupo Masterka. São necessários mais estudos, com séries maiores e randomizadas, para chegar a maiores conclusões sobre esses achados.
Keywords: Traumatismos oculares; Aparelho lacrimal/lesões; Ducto nasolacrimal; Lacerações; Stents; Microcirurgia; Intubação/métodos; Laceração canalicular; Criança; Estudo comparativo
Abstract
Objetivo: Comparar as características radiológicas e clínicas do adenoma pleomórfico primário e do carcinoma adenoide cístico da glândula lacrimal.
Métodos: Este estudo revisou retrospectivamente os achados de imagem e os prontuários médicos de casos de adenoma pleomórfico e carcinoma adenoide cístico da glândula lacrimal.
Resultados: Foram avaliados 11 pacientes com adenoma pleomórfico e 16 pacientes com carcinoma adenoide cístico. Não houve diferenças estatisticamente significativas em relação à idade e sexo. Proptose foi o sintoma de apresentação mais comum em ambos os grupos. Os carcinomas adenoides císticos foram mais propensos que os adenomas pleomórficos a apresentarem massas palpáveis, diplopia, dor e perda sensorial, mas essa diferença entre os grupos não foi estatisticamente significativa. Não houve diferenças estatísticas em termos de homogeneidade e indentação do globo ocular entre os dois tipos de tumores em imagens de tomografia computadorizada (p>0,05). Também à tomografia computadorizada, a invasão óssea, a calcificação do tumor e o sinal em cunha foram mais frequentes nos carcinomas adenoides císticos, enquanto a remodelação óssea foi mais frequente nos adenomas pleomórficos, com significância estatística para todas essas manifestações (p<0,05). À ressonância magnética, os adenomas pleomórficos foram significativamente mais propensos a terem margens bem definidas, contornos lobulados, realce heterogêneo pelo contraste e hiperintensidade na ressonância magnética ponderada em T2 (p<0,05).
Conclusão: Ao se diferenciar o adenoma pleomórfico e o carcinoma adenoide cístico da glândula lacrimal, é muito importante avaliar as características radiológicas juntamente com as características clínicas. Os contornos lobulados podem ser uma característica radiológica significativamente distinta em favor do adenoma pleomórfico.
Keywords: Aparelho lacrimal/patologia; Adenoma pleomorfo; Carcinoma adenoide cístico; Tomografia computadorizada por raios x; Imagem por ressonância magnética.
Abstract
Objetivo: O nosso objetivo neste estudo foi comparar as alterações na unidade funcional lacrimal em dois modelos de síndrome do olho seco neurogênica: desnervação sensorial da córnea versus desnervação autonômica da glândula lacrimal.
Métodos: A rede neural é um importante suporte para a unidade funcional lacrimal. Pode ser dividido em vias aferentes (sensoriais) e eferentes (autonômicas), sujeitas a doenças graves que comprometem a unidade funcional lacrimal. Ratos Wistar machos, com 8 semanas de idade, foram divididos em três grupos: 1) Controle naïve (n=16 animais); 2) Desnervação autonômica: onde os ratos foram submetidos à ablação do nervo da glândula lacrimal direita e avaliados após um e dois meses (1 M a 2 M) do procedimento (n=7 animais por subgrupo, desnervação autonômica 1M e desnervação autonômica 2M, respectivamente); 3) Desnervação sensorial induzida por colírio a 0,2% de cloreto de benzalcônio, duas vezes ao dia por 7 dias no olho direito (n=10 animais). A sensibilidade da córnea foi medida pelo teste de movimento pata-olho com capsaicina (10 μM). A PCR quantitativa em tempo real foi aplicada para comparar a expressão relativa de mRNA de citocinas pró-inflamatórias: Il1b, Il6, Tnf, Mmp9, na córnea, gânglio trigêmio e glândula lacrimal. O mRNA dos agentes pró-mitóticos Bmp7, Runx1, Runx3, Fgf10 e Smad1 foram comparados na glândula lacrimal.
Resultados: A desnervação sensorial induziu hiperalgesia da córnea (p=0,001). Desnervação sensorial e desnervação autonômica aumentaram o mRNA de citocinas pró-inflamatórias no córnea e glândula lacrimal (p<0,05), mas apenas desnervação sensorial aumentou o mRNA de Il1b e Tnf no gânglio trigêmio (p<0,05) quando comparado ao controle naïve.
Conclusões: Os modelos de desnervação autonômica e desnervação sensorial podem ter características comuns, como inflamação de diferentes partes da unidade funcional lacrimal. No entanto, a hiperestesia e os marcadores inflamatórios no gânglio trigêmio de desnervação sensorial e a expressão de mediadores regenerativos na glândula lacrimal na desnervação autonômica são características que distinguem essas doenças, podendo ser investigadas em estudos futuros que abordam o olho seco secundário ao dano neural da unidade funcional lacrimal.
Keywords: Córnea; Unidade functional lacrimal; Aparelho lacrimal; Hipersensibilidade; Ratos Wistar; Síndrome do olho seco
Abstract
Objetivo: Determinar a frequência de neoplasia escamosa da superfície ocular associada ao pterígio com apresentação clínica, em um centro de referência em Oftalmologia da região central do México.
Métodos: Revisamos os laudos histopatológicos e as lâminas de biópsia de todos os pacientes que foram submetidos à cirurgia de pterígio de 2014 a 2016 no Instituto Mexicano de Oftalmologia, na cidade de Querétaro.
Resultados: Estudamos 177 amostras de biópsia; 66% eram de pacientes do sexo feminino, sendo a mediana da idade de 52 anos. Encontramos neoplasia escamosa da superfície ocular em 11,29% (n=20). Uma amostra de biópsia mostrou um carcinoma queratinizante infiltrativo pouco diferenciado.
Conclusões: A prevalência da neoplasia escamosa da superfície ocular nessa região parece ser maior do que a indicada por outras pesquisas. Mais estudos de âmbito nacional são necessários para determinar a verdadeira prevalência da neoplasia escamosa da superfície ocular no México e examinar os fatores de risco relacionados.
Keywords: Pterígio; Neoplasias da túnica conjuntiva; Neoplasias oculares; Histopatologia; Carcinoma de células escamosas
Abstract
This study aimed to evaluate the morphometric and volumetric dimensions of the lacrimal gland in patients with inactive thyroid eye disease and compare them with the values reported in the literature. This case series evaluated consecutive patients with inactive thyroid eye disease treated at a tertiary eye hospital from 2015 to 2020. The patients' baseline demographics and clinical characteristics were obtained. The axial and coronal length, width, and volume of the lacrimal gland were measured on computed tomography scan images, and the results were statistically analyzed. A total of 21 patients (42 orbits) with inactive thyroid eye disease were evaluated. Their mean age was 49.0 ± 14.6 years, and 12 (57.1%) of them were men. The main complaint was dryness, and the majority of the patients had good vision and mild proptosis. The mean axial length and width of the lacrimal gland were 19.3 ± 3.9 mm and 7.5 ± 2.1 mm, respectively; coronal length and width, 20.4 ± 4.5 mm and 7.5 ± 2.1 mm, respectively; and lacrimal gland volume, 0.825 ± 0.326 mm3. Age, sex, or laterality were not found to be determinants of lacrimal gland enlargement. Patients with thyroid eye disease have enlarged lacrimal gland even in the nonactive phase of the disease multifactorial aspects influence the lacrimal gland in thyroid eye disease, making it difficult to establish a clear correlation with predisposing factors. Further studies are warranted to better understand the association between thyroid eye disease and the lacrimal gland.
Keywords: Graves' ophthalmology; Graves' disease; Lacrimal apparatus; Lacrimal apparatus diseases; X-ray computed tomography
Abstract
PURPOSE: The purpose of this study is to assess the long-term outcomes of modified transcanalicular diode laser dacryocys torhinostomy in a large cohort of patients affected by primary acquired nasolacrimal duct obstruction.
METHODS: This study, conducted from January 17 to June 2022, encompassed 141 patients (159 procedures) who underwent modified transcanalicular diode laser dacryocystorhinostomy (MT-DCR). The procedure employed an 810-nm diode laser. Patients were monitored for at least a year after the intervention. Anatomical success was determined by ostium patency upon irrigation, while functional success referred to epiphora resolution. Parameters studied included patient demographics, procedure duration, complications, and both anatomical and functional success. Statistical analysis was performed using the Statistical Package for the Social Sciences software, with results considered significant at a 95% confidence interval (p≤0.05).
RESULTS: A total of 159 lacrimal drainage systems (141 patients: 112 women and 29 men) were included in this study. Among them, 18 underwent bilateral procedures. The average patient age was 58 years (range: 34-91 years), and the average surgical duration was 24 minutes (range: 18-35 minutes). One year after the surgery, MT-DCR exhibited anatomical and functional success rates of 84.9% (135/159) and 83% (132/159), respectively.
CONCLUSION: MT-DCR achieved an anatomical success rate of 84.9%, reflecting an excellent outcome. However, further extensive studies with larger sample sizes and longer follow-up periods are necessary to substantiate these findings.
Keywords: Lacrimal duct obstruction; Nasolacrimal duct/surgery; Dacryocystorhinostomy; Lacrimal apparatus diseases; Laser therapy/methods; Lasers, semiconductor/therapeutic use; Regeneration
Abstract
O manejo cirúrgico de grandes tumores envolvendo o fórnice conjuntival pode ser desafiador, onde a exposição e as margens livres podem ser difíceis de serem alcançadas. Nesta série de casos, relatamos nossa experiência inicial com 4 pacientes usando a técnica de livro aberto. Através da cantotomia e da cantólise, esta abordagem cirúrgica fornece um amplo campo cirúrgico e também facilita a reconstrução do fórnice após a excisão de um tumor grande. Em nossa série, um paciente apresentou deiscência no canto lateral.
Keywords: Fornix; Aparelho lacrimal; Neoplasia da conjuntiva
Abstract
O relato descreve três casos de síndrome de sicca, inicialmente suspeitos de serem a síndrome de Sjögren, que foram negados pela investigação clínica e laboratorial. O primeiro associado ao uso de isotretinoína, um ácido retinóico, o segundo ao uso de esteroides androgênicos anabolizantes e o terceiro relacionado ao adenoma da hipófise secretora da prolactina, todos manifestaram sicca, incluindo a síndrome do olho seco após esses eventos e as manifestações persistem. A ressonância magnética revelou atrofia bilateral da glândula lacrimal. Eles eram uma mulher de 24 anos, um homem de 32 anos e uma mulher de 77 anos com sintomas crônicos da síndrome de sicca, incluindo a síndrome do olho seco. A história médica, o exame ocular, os exames laboratoriais e a ressonância magnética foram confirmados como síndrome do olho seco, no entanto, todos os exames foram negativos para a síndrome de Sjögren. A glândula lacrimal estava ausente na ressonância magnética nos três casos. A história clínica revelou que sinais e sintomas se manifestaram após exposição crônica ao ácido retinóico, esteróides anabolizantes androgênicos e adenoma secretivo da prolactina hipofisária, respectivamente. Isotretinoína crônica, esteroides anabólicos androgênicos e adenoma hipofisário secretor de prolactina ou, neste último caso, seu tratamento inibitório pode ser a causa da atrofia da glândula lacrimal, síndrome da sicca e síndrome do olho seco e diagnóstico diferencial da síndrome de Sjögren. Estudos adicionais sobre doses, duração e outras suscetibilidades aos efeitos adversos duradouros do ácido retinóico, esteroides androgênicos anabólicos e repercussões do adenoma da hipófise secretora da prolactina são necessários para confirmar e detalhar essas associações.
Keywords: Congêneres da testosterona; Isotretinoína; Síndromes do olho seco; Glândulas lacrimais; Imagem por ressonância magnética; Neoplasias hipofisárias; Adenoma; Prolactina; Síndrome de Sjögren
Abstract
A dacriocistite aguda de retenção é uma entidade incomum, o que contribui para que o diagnóstico e o tratamento não sejam corretos. Estamos descrevendo um caso de dacriocistite aguda de retenção ocorrendo em um homem diabético de 61 anos que apresentou dor intensa, edema e sinais inflamatórios acima do tendão cantal medial esquerdo. Ele não tinha histórico anterior de epífora. A tomografia computadorizada indicou dacriocistite aguda. O tratamento clínico resultou na resolução completa da condição. A irrigação, um mês após o episódio agudo, indicou sistema excretor lacrimal pérvio. A obstrução temporária que evoluiu para uma dacriocistite aguda de retenção foi provavelmente secundária a alteração nasal ou supostos dacriolitos. O tratamento clínico conservador pode levar à resolução completa da dacriocistite aguda de retenção, sem necessidade de outros tratamentos.
Keywords: Dacriocistite; Obstrução dos ductos lacrimais; Doenças do aparelho lacrimal; Ducto nasolacrimal
Abstract
O lacrimejamento é um sinal comum na prática oftalmológica, porém frequentemente negligenciado. Os autores descrevem um caso de um paciente com epífora unilateral direita com 8 anos de história que só após evoluir com dacriocistite foi submetido a semiologia de vias lacrimais. Após o diagnóstico de obstrução baixa da via lacrimal foi submetido a cirurgia de dacriocistorrinostomia, onde o saco lacrimal de aparência atípica foi biopsiado e identificado como carcinoma espinocelular. O paciente foi submetido a ressecção oncológica do tumor seguido de radioterapia adjuvante, permanecendo livre de recidiva por 2 anos. Este caso ressalta a importância de investigar causas da epífora, especialmente quando unilateral, dada sua maior associação com a obstrução de via lacrimal. Uma semiologia oportuna das vias lacrimais podem evitar atrasos no diagnóstico de obstrução secundárias a neoplasia, que apesar de incomuns, são potencialmente fatais.
Keywords: Obstrução dos ductos lacrimais; Doenças do aparelho lacrimal; Neoplasias oculares; Carcinoma de células escamosas; Imagem por ressonância magnética; Tomografia computadorizada por raios X; Humano; Relato de casos
Abstract
A disseminação metastática ocular de tumores sistêmicos é incomum, ocorrendo principalmente na coroide e em pacientes idosos. O câncer de pulmão é considerado o principal tumor metastático ocular em homens, contudo, outras doenças oculares, como as uveítes e lesões retinianas, podem mimetizar os implantes secundários tumorais nos tecidos oculares. O aspecto fundoscópico das neoplasias da coroide pode apresentar similaridade com outros processos infecciosos, especialmente o tuberculoma de coroide. Dessa forma, a investigação clínica detalhada é de grande importância no diagnóstico de pacientes com massas coroideanas, especialmente quando configuram a primeira manifestação de uma doença sistêmica e grave. Relatamos um caso raro de metástase coroideana como primeira manifestação clínica do carcinoma de células renais em um homem jovem, mimetizando um tuberculoma de coroide.
Keywords: Neoplasias renais/complicações; Metástase neoplásica; Carcinoma de células renais; Neoplasias da coroide/etiologia; Humanos; Relatos de casos
Abstract
We present a rare case of primary caruncle basal cell carcinoma (BCC), a condition with limited occurrences. Our patient, an 80-year-old woman without prior ocular pathological history, presented a 2x2mm pedunculated blackish nodular lesion on the caruncle of her left eye, without local conjunctival or cutaneous involvement. Histological analysis following complete excision confirmed the presence of basal cell carcinoma within the caruncle. Over a span of 30 months, no recurrence has been observed. While scant cases are documented in the literature, we conducted a review of these instances. Despite its infrequent manifestation, this condition should be taken into account when evaluating caruncular tumors, given its tendency to invade the orbit. Complete excision with free surgical margins is the treatment of choice, and adjuvant radiotherapy or chemotherapy might be considered.
Keywords: Conjunctival diseases; Eye neoplasms; Sebaceous gland neoplasms; Conjunctival neoplasms; Carcinoma, basal cell; Diagnosis, differential; Humans; Case reports
Abstract
Uma revisão narrativa da literatura de 57 publicações que descrevem esta patologia, publicada a partir de 2012. Os pacientes têm uma massa de crescimento lento e imóvel, que na maioria das vezes é indolor. Todos os casos foram tratados por excisão total, com exceção de um relatório de radioterapia adjuvante. Entre as estratégias terapêuticas encontradas, a ressecção total do tumor, preservando a pseudocápsula tumoral intacta, parece ser um consenso. Alternativamente, a biópsia por aspiração de agulha fina incluindo a avaliação de alterações genéticas pode representar uma ferramenta valiosa nos casos diagnósticos desafiadores. Uma biópsia incisional antes da cirurgia não é recomendada, pois a ruptura da pseudocápsula aumenta consideravelmente a recorrência do adenoma, permitindo até mesmo sua malignização. Com relação à genética, estudos atuais indicam que as aberrações moleculares envolvidas no adenoma são semelhantes às da patogênese do tumor da glândula salivar. Para casos de recorrência, a patologia torna-se difícil de tratar e múltiplas cirurgias podem ser necessárias, às vezes levando a um tratamento cirúrgico radical.
Keywords: Adenoma pleomorfo; Aparelho lacrimal; Neoplasias da glândulas salivares; Órbita; Biopsia por agulha fina
ABO is licensed under a Creative Commons Attribution-NonComercial 4.0 Internacional.
About
Issues
Editorial Board
Submission
Official publication of Conselho Brasileiro de Oftalmologia
Rua Casa do Ator, 1.117 - 2º andar - CEP: 04546-004
São Paulo - SP, Brazil
Phone: +55 11 3266-4000