Original Articles
Visualizações

Arq. Bras. Oftalmol. 2014; 77 (1): 10.5935/0004-2749.20140006

Total: 1264

Índices da córnea anterior e posterior com dois analisadores Scheimpflug

Daoud Charbel Fahd1; Carole George Cherfan1; Claudia Raad2; Marc Asouad2; Shady Tanus Awwad1

DOI: 10.5935/0004-2749.20140006

RESUMO

Objetivo: Avaliar a concordância entre as medidas de elevação e curvatura das superfícies anterior e posterior da córnea obtidos pelos analisadores de Scheimpflug Galilei e Pentacam. Método: Estudo de teste diagnóstico, prospectivo, não-intervencional realizado no Departamento de Oftalmologia do Centro Médico da Universidade Americana de Beirute. Sessenta olhos de 60 pacientes consecutivos. As medições foram feitas usando dois analisadores Scheimpflug diferentes (Galilei e Pentacam). A esfera de melhor ajuste foi fixada em 8 mm para ambos equipamentos. Paquimetria (CCT), elevação anterior (AE) e elevação posterior (PE), e curvatura foram avaliados. Coeficientes de correlação de Pearson, comparação das médias, e gráficos de Bland-Altman foram utilizados para avaliar a correlação. Resultados: A média de CCT (no ápice da córnea) foi 533 ± 35 µm usando o Galilei e 532 ± 37 µm usando o Pentacam (p=0,980). As médias centrais de AE foram de 1,25 ± 3,95 µm e 2,29 ± e 5,28 µm com o Galilei e Pentacam, respectivamente (p=0,964). As médias de centrais de PE foram 4,19 ± 8,18 µm e 5,42 ± 14,05 µm com a Galilei e Pentacam, respectivamente (p=0,956). Conclusões: Os analisadores de Scheimpflug avaliados correlacionam bem em termos de paquimetria, elevação e curvatura.

Descritores: Córnea/patologia; Córnea/anatomia e histologia; Topografia da córnea; paquimetria corneana; Fotografia/instrumentação

ABSTRACT

Purpose: To assess the agreement between the elevation and curvature measurements of the anterior and posterior corneal surfaces obtained using the Galilei Dual Scheimpflug Analyzer and those obtained using the Pentacam single Scheimpflug system. Methods: This prospective, noninterventional, diagnostic study was conducted at the Department of Ophthalmology at the American University of Beirut (Medical Center) and included 60 eyes of 60 consecutive patients. Measurements were obtained using 2 different Scheimpflug analyzers (Galilei and Pentacam). The best-fit sphere was set at 8 mm in both machines. Pachymetry (CCT), anterior elevation (AE) and posterior elevation (PE), and curvature were assessed. Pearson's correlation coefficients, comparison of means, and Bland-Altman plots were used to evaluate agreement between the 2 systems. Results: The average CCT (at the corneal apex) was 533 ± 35 µm and 532 ± 37 µm (p=0.980), the average central AE was 1.25 ± 3.95 µm and 2.29 ± 5.28 µm (p=0.964), and the average central PE was 4.19 ± 8.18 µm and 5.42 ± 14.05 (p=0.956) µm with the Galilei and Pentacam, respectively. Conclusion: The Scheimpflug analyzers correlated well in the assessment of pachymetry, elevation, and curvature.

Keywords: Cornea/pathology; Cornea/anatomy & histology; Corneal topography; Corneal pachymetry; Photography/instrumentation


THE CONTENT OF THIS ARTICLE IS NOT AVAILABLE FOR THIS LANGUAGE.


Read in English XML Print PDF English
Open Access
Share

How to cite this article:

Charbel Fahd D, George Cherfan C, Claudia Raad , Marc Asouad , Tanus Awwad S. Índices da córnea anterior e posterior com dois analisadores Scheimpflug. Arq. Bras. Oftalmol. 2014;77(1):17-20. 10.5935/0004-2749.20140006
Export citation